Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Image-Based Laser Sensor

          IX series

          Select Language

          Sensor Head

          Model

          IX-055

          IX-080

          IX-150

          IX-360

          Reference distance

          55 mm 2.17"

          80 mm 3.15"

          150 mm 5.91"

          360 mm 14.17"

          Measuring distance

          45 to 65 mm 1.77" to 2.56"

          62 to 98 mm 2.44" to 3.86"

          100 to 200 mm 3.94" to 7.87"

          280 to 440 mm 11.02" to 17.32"

          Detection area

          Scan mode

          Measuring distance of 45 mm 1.77":
          27.5 × 20.5 mm 1.08" × 0.81" (min.)
          Measuring distance of 55 mm 2.17":
          32.5 × 24.5 mm 1.28" × 0.96" (min.)
          Measuring distance of 65 mm 2.56":
          37.5 × 28.5 mm 1.48" × 1.12"
          (X direction) × (Y direction) *1

          Measuring distance of 62 mm 2.44":
          36.5 × 27.0 mm 1.44" × 1.06" (min.)
          Measuring distance of 80 mm 3.15":
          45.5 × 34.0 mm 1.79" × 1.34" (min.)
          Measuring distance of 98 mm 3.86":
          54.5 × 41.0 mm 2.15" × 1.61"
          (X direction) × (Y direction) *1

          Measuring distance of 100 mm 3.94":
          56.5 × 42.0 mm 2.22" × 1.65" (min.)
          Measuring distance of 150 mm 5.91":
          82.5 × 61.5 mm 3.25" × 2.42" (min.)
          Measuring distance of 200 mm 7.87":
          108.5 × 81.0 mm 4.27" × 3.19"
          (X direction) × (Y direction) *1

          Measuring distance of 280 mm 11.02":
          66.0 × 49.5 mm 2.6" × 1.95" (min.)
          Measuring distance of 360 mm 14.17":
          84.0 × 63.0 mm 3.31" × 2.48" (min.)
          Measuring distance of 440 mm 17.32":
          102.0 × 76.5 mm 4.02" × 3.01"
          (X direction) × (Y direction) *1

          Line mode

          Measuring distance of 45 mm 1.77":
          27.5 mm 1.08" × 0.81" (min.)
          Measuring distance of 55 mm 2.17":
          32.5 mm 1.28" (min.)
          Measuring distance of 65 mm 2.56":
          37.5 mm 1.48"
          (X direction)*1

          Measuring distance of 62 mm 2.44":
          36.5 mm 1.44" (min.)
          Measuring distance of 80 mm 3.15":
          45.5 mm 1.79" (min.)
          Measuring distance of 98 mm 3.86":
          54.5 mm 2.15"
          (X direction)*1

          Measuring distance of 100 mm 3.94":
          56.5 mm 2.22" (min.)
          Measuring distance of 150 mm 5.91":
          82.5 mm 3.25" (min.)
          Measuring distance of 200 mm 7.87":
          108.5 mm 4.27"
          (X direction)*1

          Measuring distance of 280 mm 11.02":
          66.0 mm 2.6" (min.)
          Measuring distance of 360 mm 14.17":
          84.0 mm 3.31" (min.)
          Measuring distance of 440 mm 17.32":
          102.0 mm 4.02"
          (X direction)*1

          Laser Light source

          Light source

          660 nm (visible light) wavelength red semiconductor laser

          Laser class

          Class II laser product (FDA [CDRH] part 1040.10) , Class 2 laser product (IEC 60825-1: 2014)

          Output

          0.95 mW (FDA (CDRH) Part 1040.10) , 1.6 mW (IEC 60825-1: 2014)

          Minimum detectable object size

          Scan mode

          ø0.7 mm ø0.03"*2

          ø1.0 mm ø0.04"*2

          ø1.7 mm ø0.07"*2

          ø1.8 mm ø0.07"*2

          Line mode

          0.7 mm × 0.7 mm 0.03" × 0.03"*2

          1.0 mm × 1.0 mm 0.04" × 0.04"*2

          1.7 mm × 1.7 mm 0.07" × 0.07"*2

          1.8 mm × 1.8 mm 0.07" × 0.07"*2

          Repeatability

          10 µm*3

          20 µm*3

          50 µm*3

          150 µm*3

          Estimated detection

          (Estimated detection: When measuring the height between two points, the minimum step difference is as follows.
          IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3

          Sampling cycle

          Scan mode

          120 ms (min.) (typical)

          Line mode

          6 ms/11 ms (selectable)

          Image receiving element

          Monochrome CMOS image sensor

          Image capture lighting

          Light source

          Red LED

          Lighting method

          Pulse lighting

          Temperature characteristics

          0.04 % of F.S./°C*4

          0.08 % of F.S./°C*4

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp, 5000 lux or less*5

          Ambient temperature for usage

          0 to +45 °C 32 to 113 °F (No freezing)*6

          Ambient humidity for usage

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz; double amplitude 1.5 mm 0.06" ; 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the 3 directions

          Material

          Main unit case: Zinc die-casting/Front cover: Glass, acrylic (hard coat) /
          Operation indicator cover: TPU/Connector ring: PBT/Connector Zinc die-casting

          Weight

          Approx. 190 g

          *1 X: Long-side direction of laser, Y: Short-side direction of laser
          *2 With a correctly attached reference distance. When measuring using the height tool, measurement point min., and no position adjustment in scan mode. When measuring using the height tool, tool window size min., and no position adjustment in line mode.
          *3 When measuring at the center of the field of view in scan mode using the “Max.” measurement point of a KEYENCE reference target (white diffuser) at the reference distance.
          *4 At the reference distance from the target. The F.S. for each model are as follows. IX-055: ±10 mm 0.39", IX-080: ±18 mm 0.71", IX-150: ±50 mm 1.97", IX-360: ±80 mm 3.15"
          *5 Using the default settings with a laser light source as the target.
          *6 With metal mounting.

          Sensor Amplifier

          Model

          IX-1000

          IX-1050

          Main unit / expansion unit

          Main unit

          Expansion unit

          Display

          Min. display unit

          10 µm*1

          Display range

          ±999.99 to ±999 mm (with 4 selectable steps)*1

          Tools

          Scan mode

          Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

          Line mode

          Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

          Other functions

          Common

          ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
          Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
          Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

          Scan mode

          Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
          Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
          Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

          Line mode

          Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

          Input

          Input

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Number of inputs

          8 (IN1 to IN8)

          Function

          IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
          Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

          Output

          Output

          Open collector output; NPN/PNP switchable, N.O./N.C. switchable
          For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
          For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

          Number of inputs

          10 (OUT1 to OUT10)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
          Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

          Analog voltage output

          ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

          Not available

          Analog current output

          4 to 20 mA, max. load resistance: 350 Ω*3

          Number of programs

          32

          Statistical information

          Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
          Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

          Detection history

          Saved history

          100*5

          Save conditions

          Selectable from NG only / All*5

          Ethernet

          Standard

          100BASE-TX/10BASE-T*6

          Not available

          Connector

          RJ45 8-pin connector*6

          Interface compatibility

          CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

          Number of connectible units

          Main units: 1, Expansion units: 1, Communication units (DL) : 1

          Ratings

          Power voltage

          24 VDC ±10 % (including ripple)

          Supplied from main unit

          Current consumption

          Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

          Environmental resistance

          Ambient temperature for usage

          0 to +50°C 32 to 122°F (No freezing)

          Ambient humidity for usage

          35 to 85 % RH (No condensation)

          Material

          Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
          Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
          Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

          Weight

          Approx. 210 g

          Approx. 190 g

          *1 For displaying on an IX Series control panel or PC software.
          *2 Configurable for each program.
          *3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
          *4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
          *5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.
          *6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
          *7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
          *8 Includes a DL Series communication unit.

          IX Series Control Panel

          Model

          IX-CP50

          Display panel

          5.7" TFT color LCD, 640 × 480 (VGA)

          Backlight

          Method

          White LED

          Duration

          Approx. 50,000 hours (25 °C 77 °F)

          Touch panel

          Method

          Analog resistive

          Actuating force

          0.8 N or less

          Ethernet

          Standard

          100BASE-TX/10BASE-T*1

          Connector

          M12 4-pin connector*1

          Languages

          Japanese/English/German/Simplified Chinese

          Expanded memory

          USB memory*2

          Ratings

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.3 A or less

          Environmental resistance

          Enclosure rating

          IP40

          Ambient temperature for usage

          0 to +50°C 32 to 122°F (No freezing)

          Ambient humidity for usage

          35 to 85 % RH (No condensation)*3

          Drop resistance

          1.3 m 4.3' onto concrete (2 times in an arbitrary direction)

          Vibration resistance

          10 to 55 Hz; double amplitude 0.7 mm; 2 hours in each of the X, Y, and Z directions

          Material

          Main unit case: PC/Power connector: Brass + Ni plating/
          Ethernet cable connector: Zinc + Ni plating, PA/USB connector cover: EDPM/
          Pen holder: PC/Adapter fixing hook: POM/LED lamp cover: PC/
          Mounting adapter: PC/Stylus: POM

          Weight

          Main unit: Approx. 450 g
          With wall mounting adapter and stylus attached: Approx. 485 g

          *1 Dedicated for use in connecting to the IX-1000/1050.
          *2 Use only products recommended by KEYENCE.
          *3 If the ambient operating temperature exceeds 40°C 104°F, use the product under conditions where the absolute humidity is 85% RH or less at 40°C 104°F.

          PC Software

          Model

          IX-H1

          System requirements

          Interface

          Equip the Ethernet (100BASE-TX) interface

          OS

          Either Windows 7 Home Premium/Professional/Ultimate or
          Windows 10 Home/Pro/Enterprise must be pre-installed*1

          Languages

          Japanese/English/German/Simplified Chinese

          Processor

          Compliant with OS system requirements

          Memory capacity

          Required capacity for installation

          1 GB or more

          Monitor

          Resolution: 1024 × 768 pixels or higher,
          Display color: High Color (16 bits) or higher

          Operating conditions

          .NET Framework 4.5.2 or later installed.*2

          *1 32-bit and 64-bit versions supported.
          *2 If .NET Framework 4.5.2 or later is not installed, .NET Framework 4.5.2 will be automatically installed during IX-H1 installation.