          SPECIFICATIONS

          Select Language

          Model

          LJ-G5001

          Head compatibility

          Measuring units are interchangeable without factory recalibration.

          Number of connectable sensors

          Maximum of 2 units

          Display

          Minimum display unit

          0.1 µm *1, 0.001 mm2, 0.01° (Inch mode : 0.01 Mil, 0.00001 inch)

          Maximum display range

          ±99999.9 mm, ±999999 mm2, ±99999.9° (Inch mode : ±9999.99 Mil, ±999.999 inch)

          Input terminal block

          Laser remote interlock input

          Non-voltage or voltage input *2.

          Trigger input

          For sensor head A, non-voltage input

          Timing 1 input

          Non-voltage input

          Auto-zero 1 input

          Reset input

          Output terminal block

          Analog voltage output

          ±10 V x 2 outputs, output impedance: 100 Ω

          Total judgment output

          NPN open-collector output

          Error output

          NPN open-collector output (N.C.)

          Process output

          NPN open-collector output

          Trigger input enable output

          For sensor head A, NPN open-collector output

          Adjusted error output

          Expansion connector

          Timing 2 input

          Non-voltage input

          Auto-zero 2 input

          Trigger input

          For sensor head B, non-voltage input

          Program switching input

          Non-voltage input, 4 inputs

          Memory card save input

          Non-voltage input

          Laser-Off input

          For sensor head A/B, non-voltage input

          Judgment/Binary output

          3-level judgment output: OUT1 to OUT8, total judgment output
          Binary output: OUT1 to OUT8 measured data output (21 bits)
          NPN open-collector output*3

          Strobe output

          NPN open-collector output

          Trigger input enable output

          For sensor head B, NPN open-collector output

          Adjusted error output

          Analog RGB monitor output

          SVGA (800 × 600 pixels)

          RS-232C interface

          Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)

          USB interface

          Supports USB 2.0 Hi-Speed (compatible with USB 1.1 Full Speed)

          Ethernet interface

          100BASE-TX/10BASE-T*4

          Memory card

          Compatible with NR-M32 (32 MB), GR-M256 (256MB), and NR-M1G (1GB). (with FAT32)

          Major functions

          Sensor heads calculation, Profile adjustment, Filter, Smoothing, Averaging,
          Position adjustment, OUT name change, Measurement mode selection
          (Height, position, gap, width, center position, section area, intersection, angle, profile comparison, profile tracking),
          Scaling, Average, Measurement, Measured value alarm, Tolerance setting, Auto-zero, Storage (data/profile),
          Memory card saving, Program memory, Trigger mode change, Mutual interference prevention, Measuring range change,
          Calibration, Laser light adjustment, Sampling time setting, Mask, Profile alarm setting, Inclination adjustment, Height adjustment,
          Display language switch, Setting support software connection, Trigger pitch/Measuring time display, etc.

          Rating

          Power voltage

          24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          800 mA or less with 1 sensor head/1 A or less with two sensor heads

          Environmental resistance

          Ambient temperature

          0 to +50 °C 32 to 122 °F

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 1,050 g

          *1 When LJ-G015 or LJ-G015K is connected only. When other sensor heads are connected, the minimum display unit is 1 µm.
          *2 (NPN model) The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. (PNP model) The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFFcurrent.
          *3 Time-sharing output of judgment results or binary measured data.
          The rating of the NPN open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max. The rating of the PNP open-collector output: 50 mA max. (30 V max.), residual voltage of 1 V max.
          The rating of the non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 1 V or less ON voltage, 1.0 mA or less OFF current)
          The rating of the voltage input: 26.4 V maximum rating, 10.8 V or less ON voltage, 0.6 mA or less OFF current (Trigger input terminal: 26.4 V maximum rating, 10.8 V or less ON voltage, 1.0 mA or less
          OFF current)
          *4 This is dedicated for connection with IV-series sensor.

          Tips of Measurement

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe