          Model

          LJ-X8000A

          Head input

          Up to 1 head
          Compatible with LJ-X8000 series heads and LJ-V7000 series heads

          Sampling cycle (trigger interval)

          •At LJ-X8000 Series connection: max. 16 kHz (62.5 µs)*1
          •At LJ-V7000 Series connection: max. 64 kHz (16 µs)*2
          (luminance output type of the model end B is max. 8 kHz (125 µs))*3

          Interface

          Control input

          Supports the batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP).

          Control output

          •Supports the trigger ready (READY) and system error (ERROR).
          •Photo MOSFET*4

          Synchronous input / output

          For trigger synchronization of multiple controllers*5

          Ethernet

          Supports the profile output, setting, controll, 1000BASE-T/100BASE-TX*6

          Encoder input

          One system
          RS-422 line driver output (with 5 V output: Up to 150 mA),
          Open collector output (5 V / 24 V compatible) combined use

          Response frequency

          RS-422

          Single phase/Z-phase : 1.6 MHz
          2-phase/1-multiplier : 1.6 MHz
          2-phase/2-multiplier : 3.2 MHz,
          2-phase/4-multiplier : 6.4 MHz

          Open collector (OC)

          Single phase/Z-phase : 100 kHz
          2-phase/1-multiplier : 100 kHz
          2-phase/2-multiplier : 200 kHz,
          2-phase/4-multiplier : 400 kHz

          Laser ON input

          Non-voltage Input (a short circuit via the short pin at the time of shipment from the factory)

          Ratings

          Power voltage

          24 VDC±10%

          Maximum current consumption

          1.3A

          Environmental resistance

          Ambient temperature

          0 to + 45 °C (DIN rail mounting) / 0 to + 40 °C (side mounting)

          Relative humidity

          35 to 85% RH (No condensation)

          Weight

          Approx. 700 g

          *1 When narrowing the measurement range depending on the binning settings.
          *2 When the measurement range is min., binning is ON, parallel imaging is ON. Others are default settings.
          *3 When the binning is ON, parallel imaging is ON. Others are default settings.
          *4 Both plus common connection for NPN input devices and minus common connection for PNP input devices are possible.
          *5 Dedicated to synchronous I/O between controllers (LJ-X8000A).
          *6 The communication library (DLL) and the sample program are included in the PC application (LJ-H2X).