Thrubeam Type Laser Detection Sensor

IB series

Catalogs View Catalog

Sensor Head IB-30

IB-30 - Sensor Head

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking

Specifications

Model

IB-30

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

Installation distance

0 to 300 mm 11.81"

Measurement range

30 mm 1.18"

Sampling cycle

12,500 times/sec. (80 µs)

Minimum detection target

ø0.2 mm ø0.01"*2

Repeatability

10 µm 0.39 Mil*3

Temperature characteristics

±0.1 % of F.S./°C (±30 µm 1.18 Mil)*4

Operating indicators

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Galvanized die cast

Lens cover

Glass

Cable

PVC (2 m 6.6')

Weight

Approx. 510 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm 11.81", and light is half-shielded at a position 150 mm 5.91" from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm 3.94" and full light is received.

Data Sheet (PDF) Other Models