          Micro-head Spectral-interference Laser Displacement MeterSI-F series

          SI-FA100

          Head Extension Unit

          SPECIFICATIONS

          Select Language

          Model

          SI-FA100*1

          Separate type

          SI-FA100

          Type

          Expansion controller*2

          No. of connectable spectrum units

          1

          Display

          Minimum display unit

          N/A

          Display range

          Display cycle

          Terminal block

          Laser remote interlock input

          N/A*3

          TIMING1 input

          RESET1 input

          Auto-zero1 input

          Laser control input

          Analog voltage output

          ±10 V x 1 output, Output impedance: 100 Ω*3

          Analog current output

          4 to 20 mA x 1 output, Maximum load resistance: 350 Ω*3

          Alarm output

          N/A*3

          General comparator output

          Expansion connector

          TIMING2 input

          RESET input

          Auto-zero input

          Program switch input

          Alarm output

          Comparator/ binary output

          Binary output

          Strobe output

          Binary selection output

          Binary selection input

          RS-232C interface

          N/A

          USB interface

          Ethernet interface

          Major functions

          12 Out simultaneous measurement
          calculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,
          interferometer mode, mask, connection of setting support software, etc.

          Rating

          Power voltage

          Supplied from the main controller

          Current consumption

          Environmental resistance

          Ambient temperature

          0 to +50 °C 32 to 122 °F*4

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 300 g

          *1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3).
          *2 Up to four expansion controllers can be connected to the main controller.
          *3 • NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
          • Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
          • Part of the input/output circuit of the SI Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external
          devices. For details, refer to "Precautions on wiring".
          *4 When two or more expansion controllers are connected, the ambient temperature is 0 to +40 °C 32 to 104 °F.