          Clamp-On Gas Flow MeterFD-G series

          FD-G200

          Clamp-On Gas Flow Meter DN 150A/200A

          SPECIFICATIONS

          Select Language

          Model

          FD-G200

          Pipe size

          DN (Diameter Nominal)

          150 A, 200 A

          NPS (Nominal Pipe Size)

          6", 8"

          Outer diameter of pipe

          ø163 to 171 mm 6.42" to 6.73", ø214 to 222 mm 8.43" to 8.74"

          Pipe thickness

          3.5 to 7.5 mm 0.14" to 0.30", 4.0 to 8.7 mm 0.16" to 0.34"

          Supported pipe materials

          Iron, steel, stainless steel

          Supported fluids

          Air, Nitrogen, other gases*1

          Fluid temperature

          0 to 60ºC 32 to 140 °F

          Recommended pressure

          0.4 MPa or greater (58 PSI or greater)

          Rated velocity of flow range

          Up to 15 m/s

          Rated velocity of flow range

          Actual flow rate range (typical)

          m3/h

          Pipe size 150 A: 1000.0
          Pipe size 200 A: 1800.0

          L/min

          Pipe size 150 A: 17000
          Pipe size 200 A: 30000

          CFM

          Pipe size 150 A: 600.00
          Pipe size 200 A: 1100.00

          Standard flow rate range (typical) [CFM]

          20°C 68°F 80 psi 0.55 MPa

          Pipe size 150 A: 3603.18*2
          Pipe size 200 A: 6605.84*2

          Display

          QVGA 2.2" LCD color monitor

          Display update cycle

          Approx. 3 Hz

          Display resolution

          Instantaneous flow rate

          0.1 m3/h, 1 L/min, 0.1 CFM

          Consumption/leakage amount

          0.1 m3, 1 L, 1 CF

          Response time

          1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

          Measurement accuracy

          Between 10 and 100% of F.S.

          ±2.0% of RD*3*4*5*6

          Between 1 and 10% of F.S.

          ±1.0% of F.S.*3*4*5*6

          Zero point error

          ±0.15% of F.S.*3*7

          Static leakage repeatability

          ±1.0% of RD*5*8

          Hysteresis

          Variable

          Flow units

          CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

          I/O wiring connection port

          M12 4-pin connector (male)

          Detection mode (switchable)

          ch.1

          Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*9

          ch.2

          Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*9

          Standard I/O (switchable)

          Control output (ch.1/ch.2)

          NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

          Analog output (ch.2)

          4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

          External input (ch.2)

          Short-circuit current: 1.5 mA or less, input time: 20 ms or more

          Protection circuit

          Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

          Analog input (for volume conversion)

          M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

          Power supplied to pressure sensor

          Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

          Communication interface

          USB

          USB 2.0

          Ethernet

          Standard

          IEEE 802.3u (100BASE-TX)

          Transmission rate

          100 Mbps

          Cable

          Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable

          Connector

          M12 connector (female, D-code)

          Network function

          Modbus TCP, EtherNet/IPTM, IO-Link*10

          Recording capacity

          Consumption amount/ leakage amount

          Approx. 5 years

          Events

          100

          Power supply

          Power voltage

          20 to 30 VDC including 10% ripple (P-P), Class 2

          Power consumption

          350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),
          550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

          Environmental resistance

          Enclosure rating

          IP65/67 (IEC 60529)*11

          Ambient temperature

          Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

          Relative humidity

          5 to 85%RH (no condensation)

          Vibration resistance

          10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

          Shock resistance

          100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

          Material

          Display unit

          Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

          Detection head

          Body: PPS/SUS304, rear surface: rubber

          Mounting/damping bracket

          SUS304

          Weight

          Approx. 2.8 kg

          *1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
          *2 Volume when gas at 20 ℃ 68℉ and internal pressure 80psi 0.55MPa is converted to STP (14.7 psi 101.3kPa, 32℉ 0 ℃)
          *3 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.
          *4 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
          *5 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.
          *6 The linearity error characteristic due to the pipe is not included in this value.
          *7 It is possible to reduce zero point errors by performing an origin adjustment.
          *8 This is the value within the range where measurement accuracy is guaranteed.
          *9 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.
          • ch.1: Pulse(+) mode
          • ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
          *10 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
          *11 The IP65/67 enclosure rating is lost when a USB connection is established.