          SPECIFICATIONS

          Select Language

          Model

          FD-V70AP

          Type

          DIN-rail mounting type

          Current consumption

          Normal

          At 12 V: 1,500 mW (125 mA) or less, At 24 V: 2,000 mW (83 mA) or less*1

          Eco mode

          At 12 V: 1,320 mW (110 mA) or less, At 24 V: 1,700 mW (70 mA) or less*1

          Display power

          3 digit dual row 7-segment LED (character height: Upper characters; 8 mm 0.315", red. Lower characters; 5.7 mm 0.224", green)
          Display refresh cycle: 5 times/second (10 times/second when response time is 0.5 seconds in the standard display mode)

          Operation status indicators

          Red LED x 3 (corresponding to control output 1, control output 2, and the abnormality alarm output)

          Detecting area

          FD-P05: 0.5 to 5 L/min、FD-P20/F20: 2 to 20 L/min、FD-P50/F50: 5 to 50 L/min
          FD-P100: 10 to 100 L/min、FD-F04: 0.4 to 4 L/min

          Display resolution

          [Standard display mode or averaged display mode]
          FD-P05/P100: 0.01 L, FD-P20/P50/P100/F20/F50: 0.1 L
          [Averaged 2-digit displaymode]
          FD-P05/P100: 0.1 L, FD-P20/P50/P100/F20/F50: 1 L

          Hysteresis

          Variable

          Response time (chatter prevention feature)

          Selectable from 0.5, 1, 2, 5, 20 and 60

          Accumulated flow unit

          FD-P05/F04: 0.01, 0.1, 1, 10, 100 Selectable fromthe above
          FD-P20/P50/P100/F20/F50: 0.1, 1, 10, 100, 1,000 Selectable from the above

          Integration reset/bank input

          Input time 20 ms or greater (Analog output/abnormality alarm output switchable)

          Control output/integration pulse output

          PNP open collector Max. 50 mA (30 V or less), Residual voltage 1 V or less, 2 outputs (N.O./N.C. switchable)

          Abnormality alarm output

          -

          Analog output

          4 to 20 mA Maximum load resistance 260 Ω
          Analog output range can be set with the maximum 10 % step of F.S.

          Repeatability

          ±0.5 % of F.S. or less (Fluid temperature 20 °C 68 °F at the ambient operating temperature of 25 °C 77 °F)

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C 32 to 122 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

          Material

          Main body and cover: polycarbonate, Key top: silicon rubber

          Accessories

          Power cable, mounting bracket, Instruction Manual

          Weight

          Approx. 85 g (including power cable)

          *1 Excluding analog output current. Including head block.