          FD-XS8

          Sensor head Maximum rated flow rate 8 L/min

          SPECIFICATIONS

          Select Language

          Model

          FD-XS8

          Supported pipe materials

          Metal pipes, Plastic pipes (soft/hard) *1

          Supported fluids

          Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1

          Supported fluid temperature

          0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)

          Clamp set model

          Plastic pipe/tube attachment

          FD-XC8R1, FD-XC8R2, FD-XC8R3

          Metal pipe attachment

          FD-XC8M

          Maximum rated flow rate

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : 0 to 3000 mL/min
          Outer diameter of pipe ø 8 0.31 ": 0 to 8000 mL/min

          Zero cut flow rate

          40 mL/min*2 (variable, default)

          Display resolution

          Instantaneous flow rate

          0.1/1/10 mL/min (Displayed on controller)

          Shot amount

          0.001/0.01/0.1/1 mL (Displayed on controller)

          Repeatability

          Plastic pipe/tube attachment

          Response time: 50 ms

          F.S.

          ± 0.1 %*3*4

          Instantaneous flow rate

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±3 mL/min
          Outer diameter of pipe ø 8 0.31 ": ±8 mL/min*3*4

          Response time: 500 ms

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±1.0 mL/min
          Outer diameter of pipe ø 8 0.31 ": ±2.6 mL/min*3

          Metal pipe attachment

          Response time: 50 ms

          F.S.

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±0.3 %
          Outer diameter of pipe ø 8 0.31 ": ±0.15 %*3*4

          Instantaneous flow rate

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±9 mL/min
          Outer diameter of pipe ø 8 0.31 ": ±12 mL/min*3*4

          Response time: 500 ms

          Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±2.9 mL/min
          Outer diameter of pipe ø 8 0.31 ": ±3.8 mL/min*3

          Hysteresis

          Variable

          Integrated unit display

          0.1/1/10/100/1000/10000 mL (displayed on controller)

          Display method

          Status indicator

          Environmental resistance

          Enclosure rating

          IP65/IP67 (IEC60529) , IP68G (JIS C0920) *5

          Ambient temperature for usage

          -10 to 60 °C (No freezing) 14 to 140 °F

          Ambient humidity for usage

          35 % to 85 %RH (No condensation)

          Vibration resistance

          10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

          Shock resistance

          50 G 11 ms 3 times each for X,Y,Z direction

          Material

          Sensor head

          Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM

          Clamp set

          For plastic pipe

          Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7

          For metal pipe

          Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7

          Weight

          Approx. 250 g

          *1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
          *2 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
          *3 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range.
          *4 The longer the response time is set, the more repeatability is improved. As a guideline, use √ (50 ms/response time) times.
          *5 The connector part of the sensor head cable is IP65/IP67.