Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Separate Amplifier Type Pressure Sensor

          AP-40 series

          Select Language

          Sensor head

          Model

          AP-41M

          AP-41

          AP-43

          AP-44

          AP-48

          Application

          Gauge pressure

          Differential pressure

          Type

          Negative pressure

          Positive pressure

          Compound pressure

          Rated pressure

          0 to -101.3 kPa

          0 to 1 Mpa

          +101.3 to -101.3 kPa

          -101.3 to +101.3 kPa

          Fluid type

          Air, non-corrosive gasses

          Temperature characteristics

          ±2 % of F.S. (When the temperature varies from 25 °C 77 °F)

          Pressure port

          M3 male threaded

          M5 male threaded

          R1/8

          Environmental resistance

          Pressure resistance

          500 kPa

          1.5 MPa

          500 kPa

          Ambient temperature

          0 to +50 °C 32 to 122 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 4 hours in each of the X, Y, and Z directions

          Shock resistance

          1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

          Material

          Case: PBT, Screw: SUS303, Cable: PVC

          Weight

          Approx. 68 g (including cable)

          Approx. 70 g (including cable)

          Approx. 98 g (including cable)

          Amplifier

          Model

          AP-40

          AP-40P

          Type

          Main unit, NPN

          Main unit, PNP

          Applicable sensor head

          AP-41, AP-43, AP-44

          Rated pressure

          -15 to +110 % of F.S.

          Display

          3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 5 times/sec.

          Display resolution

          AP-41: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar
          AP-43: 0.001 MPa, 0.01 kgf/cm2, 0.2 Psi, 0.01 bar
          AP-44: 0.2 kPa, 2 mmHg, 0.1 inchHg, 0.002 bar

          Display temperature characteristic

          ±1.0 % of F.S.

          Temperature fluctuation for analog output

          ±2.0 % of F.S.

          Mounting

          With supplied mounting bracket (2 types) or optional panel mounting bracket

          Response time (Chattering prevention function)

          2.5/5/100/500 ms

          I/O

          Control output

          NPN open-collector: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable)

          PNP open-collector: 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable)

          Analog voltage output

          1 to 5 V

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple 10 % or less

          Current consumption

          105 mA (12 V), 55 mA (24 V) (including sensor head)

          Environmental resistance

          Ambient temperature

          0 to +50 °C 32 to 122 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

          Shock resistance

          100 m/s2, 3 times in each of X, Y and Z axis

          Material

          Front housing: Polyamide, Rear housing: Polysulfone

          Weight

          80 g (including 2 m 6.6' cable) (28 g without cable)

          • Liquid Flow Meter Selection Site [Get Started]
          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe