Recent Searches
    Series ()
      Models ()
        Keywords

          Network Compatible Pressure SensorAP-N series

          AP-N10D

          Sensor amplifier: Dual output type

          SPECIFICATIONS

          Select Language

          Model

          AP-N10D

          Type

          Dual output type

          Applicable sensor head

          AP-41M, AP-41, AP-43, AP-44, AP-48

          Configuration/Display range

          -15 to +110 % of F.S.

          Repeatability

          ±0.2 % of F.S.

          Display resolution

          AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa
          AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa

          Power consumption

          Normal

          770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less)

          Expansion units

          Max. 16 units (Dual output type is counted as 2 units.)*1

          Control output(s)

          2*2

          Display temperature characteristic

          ±1 % of F.S. (When the temperature varies from 25 °C 77 °F)

          Response time (Chattering prevention function)

          1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2

          Power consumption

          Eco mode

          560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less)

          Environmental resistance

          Ambient temperature

          0 to +50 °C 32 to 122 °F (No freezing)*3

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Main unit and cover: Polycarbonate

          Weight

          Approx. 20 g

          *1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
          *2 Number of outputs when connected to the communication unit NU Series. There are no control output wires.
          *3 11 to 16 units connected: 0 to +45 °C 32 to 113 °F (When the sensor amplifier is installed on DIN rail on a metal plate)

          • General Catalog Request