          Digital Infrared Temperature SensorFT series

          FT-55AWP

          Amplifier: Panel Mountable, PNP

          SPECIFICATIONS

          Select Language

          Model

          FT-55AWP

          Type

          Panel mounting type

          Power voltage

          12 to 24 VDC, Ripple (P-P)10% max.

          Power
          consumption

          Normal

          1400 mW (For 12 V), 1600 mW (For 24 V)

          Eco mode

          1150 mW (For 12 V), 1350 mW (For 24 V)

          Display method

          4 + 1/two-digit 7-segment LED, dual-display (red/green) display (character height in the upper display (red): 8 mm 0.31",
          character height in the lower display (green): 5.7 mm 0.22"), Display updating cycle: 10/s

          Operation indicator

          Red LED x 3 (control output1/control output2/timing input indicator)

          Display resolution

          0.1°C or 1°C 0.2°F or 1.8°F (when using FT-H10/H20/H30), 1°C 1.8°F (when using FT-H50/H40K/H50K)

          Hysteresis

          Variable

          Response speed

          HSP, 30, 100, 200, 500, 1000, or 5000 ms can be selected (In HSP: 15 ms max.)

          Bank selection

          Pink and Purple wires can be configured for Bank Inputs #1,2 respectively for up to 4 total banks.

          External input

          Timing input

          Input time: 2 ms min.

          Bank input

          Input time: 20 ms min.

          Control output

          PNP open collector x 2 channels (N.O./N.C. selectable), 50 mA max. (30 VDC max.), residual voltage: 1 V max.

          Analog output

          4 to 20 mA, maximum load resistance: 260 Ω The upper- and lower-limit values of the analog output range can be set optionally.

          Bank specifications

          Emissivity (valid in temperature mode) and limit settings x 2 can be set for each bank.

          Environmental resistance

          Ambient temperature

          -10 to +50 °C 14 to 122 °F (No freezing)*1

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

          Material

          Main unit, Cover: Polycarbonate, Keycaps: Polyester elastomer, Cable: Vinyl chloride
          Panel mounting bracket: Polyacetal, front protection cover: Polycarbonate

          Accessory

          Panel mounting bracket, protection cover, power cable, unit cover sticker

          Weight

          Approx. 85 g

          *1 Ambient temperature when using the analog output is -10 to 45 °C 14 to 113 °F.

          • Flow Sensors
          • For Liquid Level Control
          • General Catalog Request
          • Trade Shows and Exhibitions