Main Unit SC-S11

SC-S11 - Main Unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

SC-S11

Response time

25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON)

Safety output (S-OUTPUT)

Output

Two PNP outputs

Max. load current

500 mA

Residual voltage (when ON)

2.5 V maximum (with a load current of 500 mA)

Leakage current

1.2 mA maximum

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring length

30 m maximum

Safety input (S-INPUT, enable input)

Input type

Contact output device connection or PNP output device connection

Short-circuit current

Approx 5mA

ON/OFF voltage

Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less

Wiring length

30 m maximum

Safety related input

Input type

Non-voltage contact input (EDM input, reset input)

Short-circuit current

EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input)

Wiring length

30 m max. (EDM input, reset input)

Non-safety output

Output

PNP/NPN totem pole output (auxiliary output, lockout output)

Max. load current

50mA (auxiliary output, lockout output)

Load wiring length

10 m maximum (auxiliary output, lockout output)

Non-safety input

Input type

No-voltage contact input or PNP or NPN open-collector input (external off input)

Short-circuit current

Approx 5mA (external off input)

ON/OFF voltage

Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input)

Wiring length

10 m maximum (external off input)

Protection circuit

Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection

Approved standards

EMC

EMS

IEC 61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A

Safety

ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

1.3 A (at maximum load)

Environmental resistance

Enclosure rating

IP20 (IEC60529)
Must be installed within a control panel rated at IP54 or higher.

Pollution degree

2 (IEC60664/EN50178)

Overvoltage category

2 (IEC60664, EN50178)

Insulation resistance

100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Storage temperature

-20 to +65 °C -4 to 149 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 85 % RH

Withstand voltage

1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Polycarbonate (UL94-V2)

Weight

160 g or less

*1 The following mark is displayed on the ratings indication label on the side of the main unit to identify it as a UL508-certified product.

Data Sheet (PDF) Other Models