Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Safety Laser Scanner

          SZ series

          Configuration Software

          The Easiest, Most Intuitive, Step-by-Step Scanner Configuration Software You Will Ever Use

          Configuration software SZ Configuratore is fast, easy,and loaded with useful, time-saving tools
          [SZ-01S] [SZ-04M] [SZ-16V] [SZ-16D]

          SZ-H1S Configuration Software

          Automatic -Drawing function

          Automatic -Drawing function

          For the ultimate in ease of use, simply mount the SZ in the desired location,
          clear the area, and click the "Automatic Drawing" tool. Immediately the SZ draws a zone around existing obstacles.

          User-friendly operation and diagnostics

          Simultaneous control of two individual protection zones. one unit provides the capability of two devices

          Simultaneous control of two individual protection zones One unit provides the capability of two devices
          [Industry's First] [SZ-04M]

          Unlike conventional scanners which use a single set of safety signals (OSSD1,2) requiring external input signals to toggle between protection zones, the SZ-04M features true simultaneous protection of two independent zones. No switching is required since two sets of safety signals (OSSD1,2 and OSSD3,4) are provided.

          Sends the current status to external devices State Information Output

          Sends the current status to external devices State Information Output [Industry's First] [SZ-04M] [SZ-16V] [SZ-16D]

          This function can send a signal to a PLC or other non-safety device for the intent of displaying real-time status information on an HMI or other interface. For example "Lens is soiled, please wipe clean,then reset" or "EDM Error. Please check external devices".

          Protection zones/warning zones can be configured with just the main unit, without the need for a PC

          Protection zones/warning zones can be configured with just the main unit, without the need for a PC
          [Industry's First] [SZ-01S] [SZ-04M]

          Rectangular zones can be configured without a PC through the information display. Configuration is easy and it is no longer necessary to bring a PC for on-site operation.

          OPERATING PRINCIPLE

          revolving_mirror

          Distance measurement using the TOF (Time of Flight) method
          Calculates the time during which a pulse-emitted beam returns after hitting the detection target.
           
           
          Measurement at high-resolution of 0.36°pitch
          270° range is measured in a radial fashion using the TOF method at 0.36°pitch by revolving the internal reflective mirror at the speed of 30 ms/per revolution.

          revolving_scanner

          OTHER FUNCTIONS [Industry's First]
          Suspension in Teaching mode

          This function temporarily overrides safety functions during the robot's "teach" mode. It can only be activated when the SZ receives the teach mode signal from the robot.

          Interference reduction function

          The SZ Series has two scanning cycles, which makes it possible to reduce mutual interference between the SZs
          installed face-to-face.

          Output connectable to either NPN/PNP

          Regardless of the OSSD output type (NPN, PNP) being used, all non-safety outputs can be wired for either NPN or PNP operation depending on input device polarity.

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Safety