Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Digital Fiber Optic Sensors

          FS-V30 series

          Adjustment/External Setting

          Useful Functions for Various Applications

          %Tuning

          You can set the sensitivity with just the touch of a button. When light intensity values fluctuate due to dust or misalignment, you can adjust the sensitivity by a fixed percentage. (+/-99%)

          %Tuning

          Shift Function

          Shift Function

          Adjust the current received light intensity to "0". For example. you can zero the received light intensity from a reflective sensor so that the background will display "0". This function is effective when there are only small differences between targets received light intensity.

          Display Scaling

          Display Scaling

          You can adjust the light intensity on the display. In this way, each amplifier can display the same value for the same target. (1 output type only)

          Fiber Transmission Stop Input

          When the external input is activated, LED transmission will stop on the Main unit and all connected Sub units.

          [Example of use]
          •Troubleshooting at sensor startup
          •Preventing interference with other sensors

          External Tuning

          Sensitivity can also be externally set by a PLC.
          The external input works the same as the SET button.

          Preventing Operational Errors

          Preventing Operational Errors

          Password Lock Function

          With the Password Lock function, only authorized operators can modify the settings on the FS-V30. Since the Password Levels are selectable, operation errors can be prevented.

          Inverted Display

          Inverted Display

          Depending on the mounting direction, some displays may be inverted. The digital display on the FS-V30 can be inverted, providing easy to read displays.

          Power Saving

          Power Saving

          Power Saving Function

          The lowest power consumption in its class thanks to the MEGA FALCON chip.
          The display can be turned off to reduce power consumption

          S-APC Mode + 4-Element LED

          S-APC Mode + 4-Element LED

          The Ultimate in Long Term Stability.

          The selectable S-APC function maintains a constant light level over time. The 4-element LED prevents diode deterioration over an extended period of time. Together, these functions make the FS-V30 series the easy choice for long-term, maintenance-free operation.

          Edge Inspection Mode

          Edge Inspection Mode

          Unaffected by Dirt or Temperature Change.

          This mode ignores slight variations of light intensity by dirt or temperature, and detects only the targets. It can detect slight differences of light intensity without readjustment of the sensitivity.

          Preventing Saturation

          Preventing Saturation

          Attenuate Function

          In situations where fiber units have to be mounted in close proximity to a highly reflective background, the amplifier may saturate. The selectable attenuation function adjusts transmission intensity, allowing the FS-V30 Series to be used in close proximity (enabled) or from long distance (disabled)

          Area Output

          Area Output

          Ignore Background Interference.

          Set an upper and lower detection level. The FS-V30 will output when the received signal is between the setting limits.

          Full Automatic Calibration

          Full Automatic Calibration

          No Need to Stop Targets

          When detecting falling or minute targets, it is very difficult to make sensitivity adjustments to manual fiber-optic sensors. Fully automatic calibration is unique to digital sensors. A suitable sensitivity is set by pressing the SET button while the target passes through the sensiting area.

          Maximum Sensivility Setting

          Maximum Sensivility Setting

          Ignore Backgrounds

          The sensitivity of the FS-V30 can be set to the maximum level to ignore background surfaces. This feature also makes it possible to detect targets while suppressing the influence of dust.