Digital Fiber Optic SensorsFS-V30 series

FU-86Z

Transmissive Fiber Unit

SPECIFICATIONS

Select Language

Model

FU-86Z

Optical axis diameter
(Standard target to be detected)

ø1 mm0.039"

Heat resistant temperature

100°C 212°F*1*2

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø2.2

Minimum bend radius

R5 mm0.197" Tough-Flex

Detection distance

MEGA/FINE

MEGA

3600 mm141.732"

FINE

680 mm26.772"

Other power modes

ULTRA

2200 mm86.614"

SUPER

1600 mm62.992"

TURBO

900 mm35.433"

HSP

390 mm15.354"

Minimum detectable object

Object with a diameter of 0.005 mm0.0002"*3

Environmental resistance

Ambient temperature

-40 to +100 °C -40 to 212 °F

Weight

Approx. 25 g

*1 When this product is used in an environment with a consistently high temperature, we recommend an ambient usage temperature of 90°C 194°F or less.
*2 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature.
*3 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.