          Manual-Calibration Fiberoptic SensorFS-V/T/M series (FS01)

          Fiber Amplifier, Cable Type, Main Unit, NPN

          FS-T1G

          SPECIFICATIONS

          Select Language

          Model

          FS-T1G

          Light source

          Green LED

          Response time

          250 µs

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          External calibration input
          signal

          Non-voltage input (contact, solid state)

          Input

          Control output

          NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

          Stability output

          NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*1

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 75 g

          *1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C 14 to 122 °F
          When 11 to 16 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.