          Model

          FS-M2

          FS-M1

          FS-T1

          FS-T2

          Type

          1-line expansion unit

          Main unit

          1-line expansion unit

          Output

          NPN

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

          Button

          Response time

          250 µs (FINE) /500 µs (TURBO)

          250 µs

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Input

          Non-voltage input (contact, solid state)

          Control output

          NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

          Stability output

          NPN open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max. *1

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units).*2

          Mutual interference suppression

          FINE : 4, TURBO/SUPER: 8

          4

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*3

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*3

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*4

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 40 g

          Approx. 75 g

          Approx. 40 g

          *1 Only the FS-T1 and FS-M1 can provide stability outputs.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          3 to 10 Units: -10 to 50°C 14 to 122°F, 11 to 16 Units: -10 to 45°C 14 to 113°F
          *3 Power to the FS-T2/M2 is supplied through the FS-T1/M1/V1/V11/, PS-T1, LV-21A/11A.
          *4 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C 14 to 122 °F
          When 11 to 16 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

          Model

          FS-M1P

          FS-M2P

          FS-T1P

          FS-T2P

          Type

          Main unit

          1-line expansion unit

          Main unit

          1-line expansion unit

          Output

          PNP

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

          Button

          Response time

          250 µs (FINE) /500 µs (TURBO)

          250 µs

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Input

          Non-voltage input (contact, solid state)

          Control output

          PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.

          Stability output

          PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units).*2

          Mutual interference suppression

          FINE : 4, TURBO/SUPER: 8

          4

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*4

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*4

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*3

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 75 g

          Approx. 40 g

          Approx. 75 g

          Approx. 40 g

          *1 Only the FS-T1 and FS-M1 can provide stability outputs.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          3 to 10 Units: -10 to 50°C 14 to 122°F, 11 to 16 Units: -10 to 45°C 14 to 113°F
          *3 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C 14 to 122 °F
          When 11 to 16 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.
          *4 Power to the FS-T2/M2 is supplied through the FS-T1/M1/V1/V11/, PS-T1, LV-21A/11A.

          Model

          FS-T1G

          Light source

          Green LED

          Response time

          250 µs

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          External calibration input
          signal

          Non-voltage input (contact, solid state)

          Input

          Control output

          NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

          Stability output

          NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*1

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 75 g

          *1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C 14 to 122 °F
          When 11 to 16 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

          Model

          FS-M1H

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator),
          FINE/TURBO (switch-selectable)

          Response time

          20 µs (FINE) /50 µs (TURBO)

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Control output

          NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

          Stability output

          NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*1

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 75 g

          *1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C 14 to 122 °F
          When 11 to 16 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE CORPORATION OF AMERICA 500 Park Boulevard, Suite 200, Itasca,
          IL 60143, U.S.A.
          Phone: 1-888-KEYENCE (1-888-539-3623)
          E-mail: tech@keyence.com
          Career Opportunities: KEYENCE Career Site

          Sensors