Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Multi-Purpose Digital Laser Sensor

          LV-N series

          Select Language

          Model

          LV-S41

          LV-S41L

          LV-S31

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Type

          Small

          Small side view

          Adjustable distance definite reflective

          Light source

          Visible red semiconductor laser, Wavelength: 655 nm

          Detecting
          distance

          MEGA

          600 mm 23.62"

          480 mm 18.89"

          50 to 200 mm 1.97" to 7.87"
          (Adjustment range)

          ULTRA

          500 mm 19.69"

          400 mm 15.75"

          SUPER

          400 mm 15.75"

          320 mm 12.6"

          TURBO

          300 mm 11.81"

          240 mm 9.45"

          FINE

          200 mm 7.87"

          160 mm 6.3"

          HSP

          150 mm 5.91"

          120 mm 4.72"

          Environmental resistance

          Ambient temperature

          -10 to +50 °C 14 to 122 °F (No freezing)

          0 to +50 °C 32 to 122 °F (No freezing)

          Material

          Case

          Glass reinforced plastic

          Display

          Polycarbonate

          Lens cover

          Norbornene plastic

          Acrylic

          Transmitter lens: Norbornene plastic
          Receiver lens cover: Polyarylate

          Weight

          Approx. 70 g

          Approx. 75 g

          Model

          LV-NH35

          LV-NH32

          LV-NH37

          Type

          Straight-beam coaxial

          Adjustable beam spot

          Ultra-small beam spot

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 660 nm

          Detecting
          distance

          MEGA

          750 mm 29.53"

          1200 mm 47.24"

          70±15 mm 2.76"±0.59"

          ULTRA

          600 mm 23.62"

          1000 mm 39.37"

          SUPER

          450 mm 17.72"

          750 mm 29.53"

          TURBO

          300 mm 11.81"

          500 mm 19.69"

          FINE

          150 mm 5.91"

          250 mm 9.84"

          HSP

          100 mm 3.94"

          200 mm 7.87"

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Norbornene plastic

          Acrylic (Receivers: Polyarylate)

          Glass (Receivers: Polyarylate)

          Weight

          Approx. 65 g

          Model

          LV-NH42

          Type

          Long-distance area

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 660 nm

          Detecting
          distance

          MEGA

          1200 mm 47.24"

          ULTRA

          1000 mm 39.37"

          SUPER

          750 mm 29.53"

          TURBO

          500 mm 19.69"

          FINE

          250 mm 9.84"

          HSP

          200 mm 7.87"

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Polyarylate

          Weight

          Approx. 65 g

          Model

          LV-S61

          LV-S62

          LV-S63

          Type

          Small spot

          Parallel light area

          Long-distance transparent object

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 655 nm

          Visible red semiconductor laser, Wavelength: 660 nm

          Detecting
          distance

          MEGA

          2.5 m 8.2'

          12 m (6 m) 39.4' (19.7')*1

          35 m 114.8'

          ULTRA

          2 m 6.6'

          10 m (5 m) 32.8' (16.4')*1

          30 m 98.4'

          SUPER

          1.5 m 4.9'

          8 m (3.5 m) 26.2' (11.5')*1

          25 m 82'

          TURBO

          1 m 3.3'

          5 m (2 m) 16.4' (6.6')*1

          15 m 49.2'

          FINE

          0.75 m 2.5'

          2.5 m (0.7 m) 8.2' (2.3')*1

          8 m 26.2'

          HSP

          0.5 m 1.6'

          -

          Environmental resistance

          Ambient temperature

          -10 to +50 °C 14 to 122 °F (No freezing)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Acrylic

          Reflective mirror

          Polycarbonate, acrylic

          Weight

          Approx. 70 g

          Approx. 65 g

          Approx. 110 g

          *1 Numbers enclosed in parentheses are the detecting distance for small beam spot.

          Model

          LV-NH62

          Type

          Small spot

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 660 nm

          Detecting
          distance

          MEGA

          8 m 26.2'

          ULTRA

          7 m 23'

          SUPER

          6 m 19.7'

          TURBO

          5 m 16.4'

          FINE

          3.5 m 11.5'

          HSP

          2 m 6.6'

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Norbornene plastic

          Reflective mirror

          Polycarbonate, acrylic

          Weight

          Approx. 65 g

          Model

          LV-S71

          LV-S72

          Type

          Small standard

          Small (with slit)

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 655 nm

          Detecting
          distance

          MEGA

          500 mm 19.69"

          ULTRA

          SUPER

          TURBO

          FINE

          HSP

          Environmental resistance

          Ambient temperature

          -10 to +50 °C 14 to 122 °F (No freezing)

          Material

          Case

          Metal part: Stainless steel, Plastic part: Polyarylate

          Lens cover

          Transmitter: Norbornene plastic
          Receiver: Polyarylate

          Transmitter: Norbornene plastic
          Receiver: Glass

          Weight

          Approx. 70 g

          Model

          LV-NH110

          LV-NH100

          LV-NH300

          Type

          Area thrubeam, High power

          Area thrubeam, High performance

          FDA (CDRH) Part 1040.10

          Class 1 Laser Product

          IEC 60825-1

          Light source

          Visible red semiconductor laser, Wavelength: 660 nm

          Detecting
          distance

          MEGA

          2000 mm 78.74"
          (Detecting area: 10 mm 0.39")

          2000 mm 78.74"
          (Detecting area: 30 mm 1.18")

          ULTRA

          SUPER

          TURBO

          FINE

          HSP

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Transmitter: Glass, Receiver: Polyarylate

          Weight

          Approx. 75 g

          Approx. 95 g

          Model

          LV-N11N

          LV-N12N

          LV-N11CN

          LV-N12CN

          LV-N11MN

          Type

          2 output

          1 output

          Monitor output

          Output

          NPN

          Cable/connector

          Cable

          M8 connector

          Cable

          Main/Expansion unit

          Main unit

          Expansion unit

          Main unit

          Expansion unit

          Main unit

          I/O

          Control outputs

          2 output

          1 output

          External input

          1 input

          Monitor output

          None

          1 output

          Response time

          80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
          Timer duration selectable: 1 ms to 9,999 ms,
          Maximum error against the setting value: ±10% max.

          Control outputs

          NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)
          (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
          (Multiple connections) 1 output max: 20 mA or less

          Monitor output

          -

          1 to 5 V voltage output; load resistance 10 kΩ or more; repeat precision ±0.5% of F.S.;
          response time: 1 ms (HIGH SPEED, FINE, TURBO), 1.2 ms (SUPER), 1.8 ms (ULTRA), 4.2 ms (MEGA)

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*2

          Multiple connections to
          expansion units

          Up to 17 units can be connected in total (two-output type is treated as two units)

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference
          prevention units

          Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
          Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

          Case size

          H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

          Power
          consumption

          Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*6
          Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*6
          Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)
          *7

          Environmental resistance

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)*8

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Cable

          PVC

          Case

          Main unit and cover material: Polycarbonate

          Weight

          Approx. 75 g

          Approx. 65 g

          Approx. 20 g

          Approx. 75 g

          *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
          *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
          *3 These numbers double when "DOUBLE" is selected.
          *4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
          *5 To connect more than 9 units, the power voltage must be 20 V or more.
          *6 Increases 30 mW (1 mA) for HIGH SPEED mode.
          *7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
          Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
          (1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
          *8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
          One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

          Model

          LV-N11P

          LV-N12P

          LV-N11CP

          LV-N12CP

          Type

          2 output

          1 output

          Output

          PNP

          Cable/connector

          Cable

          M8 connector

          Main/Expansion unit

          Main unit

          Expansion unit

          Main unit

          Expansion unit

          I/O

          Control outputs

          2 output

          1 output

          External input

          1 input

          Monitor output

          None

          Response time

          80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
          Timer duration selectable: 1 ms to 9,999 ms,
          Maximum error against the setting value: ±10% max.

          Control outputs

          PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
          (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
          (Multiple connections) 1 output max: 20 mA or less

          Monitor output

          -

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*2

          Multiple connections to
          expansion units

          Up to 17 units can be connected in total (two-output type is treated as two units)

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference
          prevention units

          Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
          Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

          Case size

          H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

          Power
          consumption

          Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
          Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
          Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
          *7

          Environmental resistance

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)*8

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Cable

          PVC

          Case

          Main unit and cover material: Polycarbonate

          Weight

          Approx. 75 g

          Approx. 65 g

          Approx. 20 g

          *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
          *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
          *3 These numbers double when "DOUBLE" is selected.
          *4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
          *5 To connect more than 9 units, the power voltage must be 20 V or more.
          *6 Increases 30 mW (1 mA) for HIGH SPEED mode.
          *7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
          Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
          (1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
          *8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
          One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

          Model

          LV-N10

          Type

          Zero line

          Cable/connector

          -

          Main/Expansion unit

          Expansion unit

          I/O

          Control outputs

          None

          External input

          Monitor output

          Response time

          80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
          Timer duration selectable: 1 ms to 9,999 ms,
          Maximum error against the setting value: ±10% max.

          Control outputs

          NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)
          (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
          (Multiple connections) 1 output max: 20 mA or less

          Monitor output

          -

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*2

          Multiple connections to
          expansion units

          Up to 17 units can be connected in total (two-output type is treated as two units)

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference
          prevention units

          Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
          Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

          Case size

          H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

          Power
          consumption

          Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*6
          Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*6
          Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)
          *7

          Environmental resistance

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)*8

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Cable

          PVC

          Case

          Main unit and cover material: Polycarbonate

          Weight

          Approx. 20 g

          *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
          *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
          *3 These numbers double when "DOUBLE" is selected.
          *4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
          *5 To connect more than 9 units, the power voltage must be 20 V or more.
          *6 Increases 30 mW (1 mA) for HIGH SPEED mode.
          *7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
          Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
          (1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
          *8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
          One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.