Recent Searches
    Series ()
      Models ()
        Keywords

          Ultra-small Digital Laser SensorLV-S series

          LV-12SAP

          Amplifier Unit, Expansion Unit, PNP

          SPECIFICATIONS

          Select Language

          Model

          LV-12SAP

          Type

          Expansion unit (1 line)

          Main unit/expansion unit

          Applicable model

          LV-S61/S41/S41L/S31/S71/S72

          Control output

          PNP open-collector × 2 channels, 30 VDC maximum, 100 mA or less per output

          Response time

          ExceptLV-S31

          ULTRA

          4 ms

          SUPER

          2 ms

          TURBO

          500 µs

          FINE

          250 µs

          HSP

          80 µs

          LV-S31standard mode

          500 µs

          LV-S31standard mode

          SPED2

          2 ms

          SPED3

          8 ms

          SPED4

          32 ms

          LV-S31High-speed mode

          250 µs

          Control input

          Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input

          Number of interference prevention units

          ULTRA

          4

          SUPER

          TURBO

          2

          FINE

          HSP

          0

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units).*1

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2

          Power consumption

          Normal

          1.5 W or less (62.5 mA or less at 24 V)

          Ratings

          Eco-Half Eco-All

          1.35 W or less (57.3 mA or less at 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)*3

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

          Material

          Main unit

          Main body, cover: Polycarbonate

          Weight

          Approx. 80 g (including 2 m 6.6' cable)

          *1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          1 or 2 Units: -10 to 55°C 14 to 131°F, 3 to 10 Units: -10 to 50°C 14 to 122°F, 11 to 16 Units: -10 to 45°C 14 to 113°F
          *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % or less
          *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C 14 to 131°F, 3 to 10 units connected: -10 to +50 °C 14 to 122°F, 11 to 16 units connected: -10 to +45 °C 14 to 113°F