          SPECIFICATIONS

          Select Language

          Model

          LV-52

          Type

          NPN output

          Main unit/expansion unit

          Expansion unit (1 line)

          Control output

          NPN open-collector x 2 channels, 40 VDC max., 100 mA, max. residual voltage (1.0 V max.)

          Response speed

          FINE : 80 µs , TURBO : 500 µs , SUPER : 4 ms

          Number of interference
          preventive units

          FINE : No device (0) , TURBO : 2 units , SUPER : 4 units*1

          Detection mode

          Light intensity distinction / edge detection

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 7 additional expansion units can be installed (8 units including the main unit),

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.)

          Power consumption

          1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing) *2

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit

          Polycarbonate

          Case

          Weight

          Approx. 75 g

          *1 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows :
          When 2 to 5 expansion units are additionally installed : -10 to +50ºC (14 to 122ºF).
          When 6 or 7 expansion units are additionally installed : -10 to +45ºC (14 to 113ºF).
          *2 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 2 to 5 units: -10 to +50 °C 14 to 122 °F
          When 6 to 7 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.