Recent Searches
    Series ()
      Models ()
        Keywords

          Digital Laser Sensor

          LV series

          Select Language

          Model

          LV-H35

          LV-H32

          LV-H37

          Type

          Straight-beam coaxial

          Adjustable beam spot

          Ultra-small beam spot

          FDA (CDRH) Part 1040.10

          Class II

          Light source

          Visible red semiconductor laser

          Wavelength

          660 nm

          Detecting distance

          FINE

          150 mm 5.91"

          30 to 250 mm 1.181" to 9.842"

          70 ±15 mm 2.76" ±0.59"

          TURBO

          300 mm 11.81"

          30 to 500 mm 1.181" to 19.685"

          SUPER

          600 mm 23.62"

          30 to 1000 mm 1.18" to 39.37"

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Glass reinforced plastic *1

          Lens cover

          Transparent plastic

          Acrylic *2

          Glass *2

          Weight

          Approx. 45 g

          *1 Norbornene plastic or acrylic
          *2 The LV-H32 and the LV-H37 receivers are polyarylate.

          Model

          LV-H47

          LV-H42

          Type

          Area definite reflective

          Long-distance area

          FDA (CDRH) Part 1040.10

          Class II

          Light source

          Visible red semiconductor laser

          Wavelength

          660 nm

          Detecting distance

          FINE

          55 to 85 mm 2.17" to 3.35"

          250 mm 9.84"

          TURBO

          500 mm 19.69"

          SUPER

          1000 mm 39.37"

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Glass *1

          Polyarylate

          Weight

          Approx. 45 g

          *1 The LV-H47 and the LV-H42 receivers are polyarylate.

          Model

          LV-H62

          LV-H67

          Type

          Small beam spot

          High power

          FDA (CDRH) Part 1040.10

          Class II

          Light source

          Visible red semiconductor laser

          Wavelength

          660 nm

          Detecting distance

          FINE

          2 m 6.6'

          20 m 65.6'

          TURBO

          5 m 16.4'

          30 m 98.4'

          SUPER

          7 m 23.0'

          30 m *2 98.4'

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Material

          Case

          Glass reinforced plastic

          Lens cover

          Transparent plastic *1

          Reflective mirror

          Polycarbonate, acrylic

          ABS plastic, Acrylic

          Weight

          Approx. 45 g

          *1 Norbornene plastic or acrylic
          *2 The detecting distance is 50 m 164.0' when OP-42198 is used.

          Model

          LV-H64

          LV-H65

          Type

          Long distance

          Wide

          FDA (CDRH) Part 1040.10

          Class II

          Light source

          Visible red semiconductor laser

          Wavelength

          660 nm

          Detecting distance

          FINE

          100 to 500 mm 3.94" to 19.69" (100 to 700 mm 3.94" to 27.56")*1

          100 mm 3.94" (150 mm5.91")*1

          TURBO

          200 to 850 mm (300 to 1000 mm)
          7.87" to 33.46" (11.81" to 39.37")*1

          10 to 150 mm 0.39" to 5.91" (10 to 250 mm 0.39" to 9.84")*1

          SUPER

          400 to 1200 mm (600 to 1500 mm)
          15.75" to 47.24" (23.62" to 59.06")*1

          100 to 200 mm 3.94" to 7.87" (150 to 350 mm 5.91" to 13.78")*1

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Material

          Case

          Reinforced glass/plastic

          Lens cover

          Norbornene plastic

          Reflective mirror

          Polycarbonate, acrylic

          Weight

          Approx. 45 g

          *1 The parentheses indicate the detecting distance when OP-51428 is used.

          Model

          LV-H35F*1

          LV-H62F*1

          Type

          Straight-beam coaxial

          Retro-reflective

          FDA (CDRH) Part 1040.10

          Class II

          Light source

          Visible red semiconductor laser

          Wavelength

          660 nm

          Detecting distance

          FINE

          100 mm 3.94"

          1.5 m 4.9'

          TURBO

          200 mm 7.87"

          3.5 m 3.5'

          SUPER

          450 mm 17.72"

          5 m 16.4'

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Case

          Fluoroplastic (PFA)

          O-ring

          Fluororubber

          Lens cover

          Glass

          Weight

          Approx. 80 g

          Approx. 100 g

          *1 The cable minimum bend radius is 25 mm 0.98".

          Model

          LV-21A

          LV-21AP

          LV-22A

          LV-22AP

          LV-20A

          Type

          NPN output

          PNP output

          NPN output

          PNP output

          NPN output

          Main unit/expansion unit

          Main unit

          Expansion unit (1 line)

          Expansion unit (0 line)

          Control output

          NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          PNP open-collector x 2 channels, 30 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          Response speed

          FINE : 80 µs , TURBO : 500 µs , SUPER , TURBO : 4 ms

          280 µs to 4.7 ms

          Monitor output

          NPN output

          Number of interference
          preventive units

          FINE : None , TURBO : 2 units , SUPER : 4 units

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 7 additional expansion units can be installed (8 units including the main unit),

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less

          12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.)

          Power consumption

          1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing) *1

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit

          Polycarbonate

          Case

          Weight

          Approx. 120 g

          Approx. 75 g

          Approx. 120 g

          Approx. 35 g

          *1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 2 to 5 units: -10 to +50 °C 14 to 122 °F
          When 6 to 7 units: -10 to +45 °C 14 to 113 °F
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Sensors