Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Network Communication Unit

          DL series

          Select Language

          Model

          DL-EP1*1

          Indicator

          Link/activity indicator (LINK/ACT): Green LED, Module status indicator (MS): 2-color (green/red) LED,
          Network status indicator (NS): 2-color (green/red) LED, Sensor communication indicator (D-bus) 2-color (green/red) LED

          Sensor
          connection
          specifications

          Connectable
          sensors

          Sensor amplifiers with D-bus support*2

          Number of
          connectable
          sensor units

          Up to 15 units

          EtherNet/IPTMspecifications

          Compliant functions

          Cyclic communication (Implicit messaging)Message communication (Explicit messaging)Compatible with UCMM and Class 3

          Number of connections

          64

          EtherNet/IPTM specifications

          RPI (Transmission cycle)

          0.5 to 10000 ms (0.5 ms unit)

          EtherNet/IPTMspecifications

          Tolerable communication bandwidth forcyclic communication

          6000pps

          EtherNet/IPTM specifications

          Conformance test

          Compatible with Version A7

          Power voltage

          20 to 30 VDC, including ripple, Ripple (P-P): 10% max. Class 2 (Supplied via connected sensor amplifier)

          Power consumption

          1500 mW or less (at 30 V 50 mA max)

          Environmental resistance

          Pollution degree

          2

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Materials

          Main unit case: Polycarbonate

          Weight

          Approx. 70g

          *1 For connecting with sensor, please refer to the user's Manual
          *2 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

          Model

          DL-PN1

          Type

          PROFINET Network communication unit

          PROFINET
          specifications

          Conformance class

          Conformance Class A

          Number of connections

          1

          Compliant protocol

          LLDP, DCP

          Update time

          2 to 512 ms

          Conformance test

          V2.2.4

          Device type

          Data I/O Communication
          Record data Communication

          GSDML Version

          Ver. 2.3

          Rating

          Power voltage

          20 to 30 VDC, including Ripple (P-P) 10 %
          (Supplied from the connected sensor amplifier)

          Weight

          Approx. 70 g (Including the connector)

          Model

          DL-PD1

          Sensor
          connection
          specifications

          Connectable
          sensors

          Sensor amplifiers with D-bus support*1

          Number of
          connectable
          sensor units

          15 units max.*2

          PROFIBUS
          DP
          specifications

          Device type

          DP-V1 Slave (D-sub 9 pin, Number of the ports: 1)

          Communication speed

          9.6 kbit/s to 12 Mbit/s

          Cable length

          9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m
          187.5 kbit/s : 1000 m
          500 kbit/s : 400 m
          1.5 Mbit/s : 200 m
          3 / 6 / 12 Mbit/s : 100 m

          Power voltage

          20 to 30 VDC, including ripple (p-p) 10%
          (This voltage is supplied from the connected sensor amplifier.)

          Power consumption

          1600 mW or less (65 mA max. at 24 V)

          Environmental resistance

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Materials

          Main unit case and dust cover: Polycarbonate PROFIBUS connector: Steel – Nickel plating

          Weight

          Approx. 65 g

          *1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
          *2 Varies with the sensor amplifiers connected.

          Model

          DL-CL1*1

          Supported version

          Version 2.00, version 1.10 (switchable)

          CC-Link specifications

          No. of occupied stations

          Version 2.00: 1 station x 8, 2 stations x 8, 4 stations x 2 (switchable), version 1.10: 1 station, 2 stations, 4 stations (switchable)

          Station type

          Remote device station

          Transmission speed

          156 kbps/625 kbps/2.5 Mbps/5 Mbps/10 Mbps

          Station number settings

          1 to 64

          Power voltage

          20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

          Weight

          Approx. 80 g

          *1 For connecting with sensor, please refer to the user's Manual

          Model

          DL-RS1A*1

          Synchronization between the transmitter and receiver

          Asynchronous

          Transmission code

          ASCII

          Baud rate

          2,400/4,800/9,600/19,200/38,400 bps selectable (Factory-setting: 9,600 bps)

          Data bit length

          8 bits/7 bits selectable (Factory-setting: 8 bits)

          Parity check

          None/Even/Odd selectable (Factory-setting: None)

          Stop bit length

          1 bit

          Data delimiter

          Data reception: automatically recognizes CR or CR+LF
          Data transmission: Fixed to CR+LF

          Indicator

          Communication indicator lamp (green x 2), Alarm indicator lamp (red),
          Power indicator lamp (green)

          Sensor
          connection
          specifications

          Number of
          connectable
          sensor units

          Up to 15 units (including main unit)

          Power voltage

          20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

          Power consumption

          25 mA max.

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Materials

          Case/Polycarbonate

          Weight

          Approx. 53 g

          Communication method

          Full duplex

          *1 For connecting with sensor, please refer to the user's Manual

          Model

          DL-DN1*1

          DeviceNetTM specifi cations

          Network power supply

          11 to 25 VDC (supplied from DeviceNetTM communication power supply)

          Indicator

          Network status indicator: 2-color (green/red) LED, Module status indicator: 2-color (green/red) LED,
          Sensor communication indicator: 2-color (green/red) LED

          Sensor
          connection
          specifications

          Connectable
          sensors

          Sensor amplifiers with D-bus support*2

          Number of
          connectable
          sensor units

          Up to 15 units

          DeviceNetTM specifi cations

          Compliant functions

          Remote I/O communication (polling) Explicit messaging

          Address setting

          0 to 63 (PGM compatible)

          Baud rate (automatically switched)

          500 kbps/250 kbps/125 kbps

          Maximum cable length

          500 kbps

          thick cable

          100 m 328.09' (thick cable)

          thin cable

          250 kbps

          thick cable

          250 m 820.21' (thick cable)

          thin cable

          100 m 328.09' (thick cable)

          125 kbps

          thick cable

          500 m 1640.42' (thick cable)

          thin cable

          100 m 328.09' (thick cable)

          Power voltage

          20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

          Power consumption

          660 mW or less (at 30 V, 22 mA max.)

          Environmental resistance

          Pollution degree

          2

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Materials

          Main unit case and dust cover: Polycarbonate, DeviceNetTM connector: Polyamide (plug), PUT (socket)

          Weight

          Approx. 80 g

          *1 For connecting with sensor, please refer to the user's Manual
          *2 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

          Model

          DL-RB1A*1

          Indicator

          Alarm indicator lamp (red), Power indicator lamp (green)

          Sensor
          connection
          specifications

          Number of
          connectable
          sensor units

          Up to 15 units (including main unit)

          BCD output specifications

          I/O terminal

          34-pin connector (MIL standard)

          Control output

          BCD output: 4 outputs (1 digit) x 6 digits, signed output, strobe output, alarm output, NPN open-collector output: 40 V, 20 mA or less, residual voltage: 1 V or less, positive logic/negative logic (switchable)

          Control input

          ID selection input: 4 inputs, data request input, no-voltage input (with contacts, without contacts); input time: 2 ms or more; short-circuit current: 1 mA

          Power voltage

          20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier)

          Power consumption

          27 mA max.

          Environmental resistance

          Ambient temperature

          -10 to +55 °C 14 to 131 °F

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Materials

          Case/Polycarbonate

          Weight

          Approx. 46 g

          *1 For connecting with sensor, please refer to the user's Manual