          NU-PD1

          PROFIBUS DP compatible Network Unit

          SPECIFICATIONS

          Select Language

          Model

          NU-PD1

          Sensor connection

          Connectable sensors

          Sensors with N-bus support *1

          Number of connectable units

          16 units max. *2

          Power supply

          Power is supplied from the NU-PD1 via wiring-saving connector.

          Allowable passing current

          Overall 1200 mA or less *3

          PROFIBUS
          DP
          specifications

          Device type

          DP-V1 Slave (D-sub9 pin, Number of the ports: 1)

          Communication speed

          9.6 kbit/s to 12 Mbit/s

          Cable length

          9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m
          187.5 kbit/s : 1000 m
          500 kbit/s : 400 m
          1.5 Mbit/s : 200 m
          3 / 6 / 12 Mbit/s : 100 m

          Power voltage

          24 VDC ±10%; ripple (P-P) 10% or less, Class 2 *4

          Power consumption

          1300 mW or less (at 24 V, 52 mA max.) *5

          Environmental resistance

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)*6

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          IEC60068-2-6 2G (10 to 500 Hz, 2 hours each in X, Y, Z direction)

          Shock resistance

          IEC60068-2-27 30G (11 ms, 3 times each in X, Y, Z direction)

          Material

          Main unit case and dust cover: Polycarbonate
          PROFIBUS connector: Steel – Nickel plating
          Power supply connector: Polyamide (plug), PBT (socket)

          Weight

          Approx. 70 g (including connectors)

          *1 N-bus is the name of KEYENCE's wiring-saving system for sensors.
          *2 Varies with the sensors connected.
          *3 Indicates the current that can be supplied to the NU-PD1 and to the sensors linked to the NU-PD1.
          *4 Be sure to be used within the supply-voltage range of the sensor connecting to the NU-PD1.
          *5 Exclusive of the current supplied to the sensors connected.
          *6 1 to 2 units connected: -10 to +55 °C 14 to 131 °F, 3 to 10 units connected: -10 to +50 °C 14 to 122 °F,
          11 to 16 units connected: -10 to +45 °C 14 to 113 °F
          When a two-output type of sensor is connected, the sensor is counted as two units.