          Model

          LR-TB5000CL

          Type

          Cable with connector M12

          Detectable distance

          60 to 5000 mm 2.36" to 196.85"*1

          Spot diameter

          Variable
          (use a spot diameter of 40 mm 1.57" or less)

          Response time

          2 ms/20 ms/50 ms/200 ms/2000 ms
          selectable

          Light source

          Type

          Red laser (660 nm)

          Laser class

          Class 1 laser product
          (IEC60825-1,FDA (CDRH) Part1040.10*2)

          Mutual interference prevention function

          4 units (when using the interference prevention function)

          Timer

          OFF/OFF delay/ON delay/One-shot

          Power voltage

          20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

          Current consumption

          50 mA or less (without load)*3

          I/O

          Control output

          NPN open collector/PNP open collector selectable
          30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
          N.O./N.C. selectable
          *4*5

          Analog output

          Current output/Voltage output selectable
          Current output: 4 to 20 mA with a max. load resistance of 500 Ω
          Voltage output: 0 to 10 V with an external load resistance of 5 kΩ or more
          *4*5

          Protection circuit

          Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

          Environmental resistance

          Enclosure rating

          IP65/IP67 (IEC60529)

          Ambient light

          Incandescent lamp/Sunlight: 10,0000 lux or less

          Ambient temperature

          -20 to +55 °C -4 to 131 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Shock resistance

          1,000 m/s2, 6 times in each of the X, Y, and Z directions

          Material

          Case: Zinc die cast (Nickel chrome plating),
          Indicator cover and buttons: PES,
          Lens cover and display: PMMA (scratch-resistant coating specifications),
          Cable bushing: PBT,
          Cable: PVC,
          M12 connector: TPE, PBT, Nickel-plated brass

          Accompanying items

          Instruction manual

          Weight

          Approx. 160 g

          *1 The range for displayable distance is from 50 to 5200.
          *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
          *3 150 mA or less(with load)
          *4 You can select the I/O from the following combinations.
          Control output × 2, control output + external input
          Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
          External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
          (For details on the setting method, see the instruction manual.)
          *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
          If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Sensors