          SPECIFICATIONS

          Select Language

          Model

          IA-065

          Reference distance

          65 mm 2.56"

          Measurement range

          55 mm to 105 mm 2.17" to 4.13"

          Light source

          Type

          Red semiconductor laser, wavelength: 655 nm (visible light)

          Laser class

          Class II (FDA (CDRH) Part1040.10)
          Class 2 (IEC 60825-1)

          Output

          560 µW

          Spot diameter (at standard distance)

          Approx. 550 x 1,750 µm 21.65 x 68.9 Mil

          Linearity

          ±0.1% of F.S. (F.S.=±10 mm 0.39",
          55 to 75 mm 2.17" to 2.95")*1

          Repeatability

          4 µm 0.16 Mil*2

          Sampling cycle

          0.33/1/2/5 ms (4 levels available)

          Operation status indicators

          Laser warning: Green LED, Analog output: Red LED, Measurement center: Green LED

          Temperature characteristics

          0.06% of F.S./°C (F.S.=±10 mm 0.39",
          55 to 75 mm 2.17" to 2.95")

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp: 7,500 lux*3

          Ambient temperature

          -10 to +50 °C 14 to 122 °F (No condensation or freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

          Material

          Housing material: PBT Metal parts: SUS304 Packing: NBR Lens cover: Glass Cable: PVC

          Weight

          Approx. 130 g (including cable)

          *1 Value when measuring the KEYENCE standard target (white diffuse object).
          *2 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16.
          *3 Value when the sampling rate is set to 2 ms or 5 ms.