Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Inductive Gauging SensorAS series

          AH-809

          Sensor Head

          SPECIFICATIONS

          Select Language

          Model

          AH-809

          Type

          Sensor head for high temperatures

          Amplifier unit

          AS-425K

          Shape

          Cylindrical, diameter: 9.4

          Measuring range

          0.5 to 1.0 mm0.02" to 0.039"

          Analog output voltage

          Output voltage

          0.5 to 1.0V

          Straight line range

          Impedance

          100 Ω

          Resolution

          0.4% of F.S.*1

          Linearity

          ±4% of F.S.

          Response

          3.3kHz (-3dB)

          Temperature
          fluctuation

          Sensor head

          0.14% of F.S./°C*2

          Temperature characteristics

          Amplifier unit

          0.1% of F.S./°C*2

          Rating

          Power voltage

          115/230 VAC ±15 %, 50/60 Hz

          Power consumption

          6VA

          Environmentalresistance

          Enclosure rating

          Sensor head

          Heat-resistant type*3

          Operating ambient temperature

          -10 to 200°C 14 to 392°F, No condensation

          Amplifier unit

          0 to +50°C 32 to 122°F

          Environmental resistance

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Weight

          Sensor head

          Approx 55g

          Weight (including cord)

          Amplifier unit

          Approx 180 g (including the cable)

          *1 The AS-425K full scale is 0.5 to 1.0 mm (0.5 mm) 0.0197" to 0.0394"(0.0197"). The temperature characteristics refer to data when the temperature is in the range of +23 to +200°C +73.4 to +392°F.
          *2 When the distance between the sensor head and the target is within 50% of the measurement range.
          *3 The AH-809 is not constructed to be waterproof, so avoid using this product in an environment in which the product will be directly subjected to liquids or steam.

          Sensor Library

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe