Recent Searches
    Series ()
      Models ()
        Keywords

          Inductive Gauging SensorEX-500 series

          EX-016

          Sensor Head

          SPECIFICATIONS

          Select Language

          Model

          EX-016

          Type

          Sensor head

          Amplifier unit

          EX-505

          Shape

          M16, Threaded, Non-shielded

          Measuring range

          0 to 5 mm 0.20"

          Analog output

          Output voltage

          0 to 5 V (Output impedance: 100 Ω)*1

          Impedance

          100 Ω*2

          Output current

          4 to 20 mA (Applicable load: 0 to 350 Ω)*3

          Resolution

          0.03 % of F.S. (RESPONSE = 3, 4)*2

          Linearity

          ±0.3 % of F.S. (RESPONSE = 2, 3, 4)*3

          Response time
          (Response mode)

          0.1 ms (RESPONSE = 1), 1 ms (RESPONSE = 2), 10 ms (RESPONSE = 3), 100 ms (RESPONSE = 4)*2

          Disconnection alarm output (N.C.)

          NPN: 100 mA max. (40 V), Residual voltage: 1 V max.*4

          Functions

          Auto-zero function/Auto-span function, Response time selector function/
          Preset metal characteristic memory function, Cable length selector function/Interference suppression function

          Temperature characteristics

          0.03 % of F.S./°C*5*2

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          220 mA max.

          Environmental resistance

          Enclosure rating

          IP67

          Ambient temperature

          -20 to +105 °C -4 to 221 °F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 63 g

          *1 The above data was obtained using an aluminum target (A5052 t = 1 mm 0.04).
          When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials.
          *2 The above data was obtained using an aluminum target (A5052 t = 1 mm 0.04"). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials.
          *3 The above data was obtained using an aluminum target (A5052 t = 1 mm 0.04). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials.
          *4 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter.
          *5 When the distance between the sensor head and the target is 50 % of the measuring range and the operating temperature is 10 to 40 °C (50 to 104 °F) (EX-008) or 0 to 50 °C (32 to 122 °F) (EX-016 and
          EX-022).