Static-Sensing IonizerSJ-H series

SJ-H180A

Bar Type Main Unit, Standard Model 1800 mm

SPECIFICATIONS

Select Language

Model

SJ-H180A

Type

HA

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7,000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2,000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photo-relay, 100 mA max. (40 V max.)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

1,800 mm 70.87"*2

No. ofelectrodes

28

Dimensions

Total length (A)

1,800 mm 70.87"*3

Static elimination bar length (B)

1760

Mounting pitch (C)

1785

Electrode pitch and length (D)

P60 x 27 = 1,620

Nozzle pitch and length (E)

P120 x 13 = 1,560

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

500 mA (at 24 VDC), 350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main unit

ABS resin/PC

Weight

Controller

150 g

Static elimination bar

1,750 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a distance of 50 mm 1,.97".
*3 The total length includes the end units.