Model

SJ-M021

SJ-M021G

Type

Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max.*1

Ion balance

±15 V or less*2

Max. air pressure

0.001 to 0.5 MPa*3

Min. air pressure

With SJ-ML

0.02 MPa (20 Nl/min)

With SJ-MS/ML1

0.03 MPa (20 Nl/min)

With SJ-MS/ML2

0.02 MPa (20 Nl/min)

With SJ-MS/ML3

0.08 MPa (50 Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +80 °C 32 to 176 °F*4*5

Relative humidity

35 to 65 % RH

Weight

Approx. 600 g

*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %)
*2 Values obtained at an installation distance of 50 mm 1.97" and air flow rate of 20 Nl/min [ambient operating temperature +20 to +30 °C +68 to +86 °F, ambient operating humidity 40 to 60 % RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding +35 °C 95 °F. Use clean or dry air at a temperature of -20 °C -4 °F or less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40 °C 104 °F or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40 °C 104 °F.

Model

SJ-M031C

SJ-M031G

SJ-M071C

SJ-M071G

Type

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Ion balance

±30 V*1

±30 V*4

±30 V*1

±30 V*4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Air purge supplied pressure

0.2 MPa or less

Effective length

164 mm 6.457"*2

324 mm 12.756"*5

Total length

220 mm 8.66"*3

380 mm 14.961"*3

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 65 % RH (No condensation)

Weight

Approx. 600 g

Approx. 720 g

*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None
*2 Elective length indicates the static elimination rangeat 50 mm 1.97" operating distance.
*3 The overall length includes mounting brackets.
*4 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode
*5 Elective length indicates the static elimination rangeat 50 mm operating distance.