Sensor Amplifier for IV-HG, Main unit IV-HG10

IV-HG10 - Sensor Amplifier for IV-HG, Main unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

IV-HG10

Type

Main unit

Tools

Type

Shape Detection, Color Area*1, Area*2, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment), OCR*3

Number

Detection tools: 16 tools, position adjustment tool: 1 tool*4

Switch settings (programs)

32 programs

Image history

Numbers

When using a color type head: 100 images*5, when using a monochrome type head: 300 images*6*7

Condition

NG only/All is selectable*7

Analysis information

OFF/Statistics/Histograms/Matching rate list is switchable
Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools
Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs
Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*8

Other functions

HDR, HighGain, Color filters*1, Digital zoom (2x, 4x)*9, Brightness correction, Tilt correction, White balance*1, Mask function, Color histogram, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Direct connection (2 units or more), Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold

Indicators

PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

Input

Type

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Inputs

6 inputs (IN1 to IN6)

Function

IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input

Output

Type

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 1.5 V or lower
For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 2 V or lower

Outputs

8 outputs (OUT1 to OUT8)

Function

Enable by assigning the optional functions
Assignable functions: Total judgment result, RUN, BUSY, Error, Position adjustment result, Judgment result of each tool,
Result of the logical operation of each tool, Main unit/expansion unit logical output

Ethernet

Standard

100BASE-TX/10BASE-T*10

Connector

RJ-45 8pin connector*10

Network function

FTP client, EtherNet/IP, PROFINET

Rating

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

0.8 A or less. 1.5 A or less when also using an expansion unit (IV-HG15). (The output load is excluded.)

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)*11

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit case: Polycarbonate

Weight

Approx. 150 g

*1 Color type only
*2 Monochrome type only
*3 Supported with Ver. R5.00.00 or later.
*4 Tools can be installed by programs.
*5 When using the FTP client function: 70 pictures
*6 When using the FTP client function: 210 pictures
*7 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV-H/IV-HG Series (IV-H1).
*8 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV-H/IV-HG Series (IV-H1).
*9 Possible with both the color type and monochrome type
*10 This is for connection with the intelligent monitor (IV-M30) or software for the IV-H/IV-HG Series (IV-H1).
*11 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate.

Data Sheet (PDF) Other Models