This might be a "System Error" or wrong code.
System Error
Alert: AUX Overcurrent
The SZ-V detects an overcurrent on the AUX output. The AUX output enters the OFF-state after the SZ-V detects this alert. (The check pulse is intermittently output.) The OSSD continues normal operation.
Check the wiring between the AUX outputs and the loads, and whether the loads are broken or not. Also check the current on AUX outputs.
Alert: IP address duplication
The SZ-V IP address is duplicated by another device.
Reconfigure the IP address. For details, see “SZ-V Series User’s Manual”.
Window alert
The window of scanner head 1 may be polluted or damaged.
The OSSD may go to the OFF-state if the situation is left as it is. Clean the window.
Window alert
The window of scanner head 2 may be polluted or damaged.
The OSSD may go to the OFF-state if the situation is left as it is. Clean the window.
Window alert
The window of scanner head 3 may be polluted or damaged.
The OSSD may go to the OFF-state if the situation is left as it is. Clean the window.
Light interference alert
Scanner head 1 is experiencing light interference, such as from an incandescent lamp, fluorescent lamp, stroboscopic light, or photoelectric sensor. There may also be mutual interference between SZ-Vs.
While the SZ-V is operating normally, the OSSD may go to the OFF-state unintentionally.
Light interference alert
Scanner head 2 experiencing light interference, such as from an incandescent lamp, fluorescent lamp, stroboscopic light, or photoelectric sensor. There may also be mutual interference between SZ-Vs.
While the SZ-V is operating normally, the OSSD may go to the OFF-state unintentionally.
Light interference alert
Scanner head 3 experiencing light interference, such as from an incandescent lamp, fluorescent lamp, stroboscopic light, or photoelectric sensor. There may also be mutual interference between SZ-Vs.
While the SZ-V is operating normally, the OSSD may go to the OFF-state unintentionally.
Alert: Highly-reflective background
There is a highly-reflective background behind the specified protection zone of scanner head 1, which may impact the detection capability.
Highly reflective backgrounds must not be positioned within 1.5 m from the boundary of the protection zone. (the background itself must be removed or the reflectance must be reduced). Unless the above-mentioned countermeasures are taken, 200 mm must be added as supplementary necessary distance to the protection zone during the calculation of the minimum safety distance.
Alert: Highly-reflective background
There is a highly-reflective background behind the specified protection zone of scanner head 2, which may impact the detection capability.
Highly reflective backgrounds must not be positioned within 1.5 m from the boundary of the protection zone. (the background itself must be removed or the reflectance must be reduced). Unless the above-mentioned countermeasures are taken, 200 mm must be added as supplementary necessary distance to the protection zone during the calculation of the minimum safety distance.
Alert: Highly-reflective background
There is a highly-reflective background behind the specified protection zone of scanner head 3, which may impact the detection capability.
Highly reflective backgrounds must not be positioned within 1.5 m from the boundary of the protection zone. (the background itself must be removed or the reflectance must be reduced). Unless the above-mentioned countermeasures are taken, 200 mm must be added as supplementary necessary distance to the protection zone during the calculation of the minimum safety distance.
Muting Lamp Alert (Disconnection)
There is a problem where the muting lamp is connected to the muting lamp output. (The muting lamp is disconnected or it is broken.)
Please check the following:
Muting Lamp Alert (Overcurrent)
The muting lamp connected to the muting lamp output has an overcurrent exceeding the rated current.
Please check the following:
Camera error
An error has occurred with the camera area of scanner head 1.
Turn the power of the SZ-V off and then on again. If turning the power back on does not resolve the error, replace the scanner head.
Camera error
An error has occurred with the camera area of scanner head 2.
Turn the power of the SZ-V off and then on again. If turning the power back on does not resolve the error, replace the scanner head.
Camera error
An error has occurred with the camera area of scanner head 3.
Turn the power of the SZ-V off and then on again. If turning the power back on does not resolve the error, replace the scanner head.
Detection History Error
The detection history cannot be retrieved correctly.
Transfer the settings again. If that does not resolve the error, replace the display unit.
Detection history error
The detection history for scanner head 1 cannot be retrieved correctly.
Transfer the settings again. If that does not resolve the error, replace the scanner head.
Detection history error
The detection history for scanner head 2 cannot be retrieved correctly.
Transfer the settings again. If that does not resolve the error, replace the scanner head.
Detection history error
The detection history for scanner head 3 cannot be retrieved correctly.
Transfer the settings again. If that does not resolve the error, replace the scanner head.
EEPROM access error
Cannot read EEPROM data correctly.
Transfer the settings again. If that does not resolve the error, replace the display unit.
Safety Network Number (SNN) or IP Address mismatched.
Check the originator (controller) settings.
Transfer the CIP Safety related settings again.
If that does not resolve the error, replace the display unit.
Output ownership is established with another controller.
"Reset Ownership" is needed.
Configuration signature ID (SCCRC) or Configuration Signature Date/Time (SCTS) mismatched.
Check the originator (controller) settings.
Transfer the CIP Safety related settings again.
If that does not resolve the error, replace the display unit.
CIP Safety communication error (Timeout).
Check the network cable connection and connection reaction time limit.
PROFIsafe parameter error.
F_Source_Add is incorrect.
Transfer the PROFIsafe related settings again. If that does not resolve the error, replace the display unit.
PROFIsafe parameter error.
F_Dest_Add is incorrect.
Transfer the PROFIsafe related settings again. If that does not resolve the error, replace the display unit.
PROFIsafe parameter error.
PROFIsafe parameter error was detected.
Transfer the PROFIsafe related settings again. If that does not resolve the error, replace the display unit.
PROFIsafe communication error.
PROFIsafe Communication failed.
Check the network cable connection and the value of F_WD_Time.
The window of scanner head 1 may be polluted or scratched.
Clean the window.
If the error continues after cleaning, replace the window.
Window error
The window of scanner head 1 may be broken.
Clean the window.
If the error continues after cleaning, replace the window.
The window of scanner head 2 may be polluted or scratched.
Clean the window.
If the error continues after cleaning, replace the window.
Window error
The window of scanner head 2 may be broken.
Clean the window.
If the error continues after cleaning, replace the window.
The window of scanner head 3 may be polluted or scratched.
Clean the window.
If the error continues after cleaning, replace the window.
Window error
The window of scanner head 3 may be broken.
Clean the window.
If the error continues after cleaning, replace the window.
MI error (man-made interference error)
MI error (man-made interference error)
MI error (man-made interference error)
OSSD error
OSSD error
OSSD error
OSSD error
OSSD 1 Overcurrent Error
Overcurrent occurs on OSSD 1.
Check the wiring between OSSD 1 and the load, and whether the load is broken or not.
OSSD 2 Overcurrent Error
Overcurrent occurs on OSSD 2.
Check the wiring between OSSD 2 and the load, and whether the load is broken or not.
OSSD 3 Overcurrent Error
Overcurrent occurs on OSSD 3.
Check the wiring between OSSD 3 and the load, and whether the load is broken or not.
OSSD 4 Overcurrent Error
Overcurrent occurs on OSSD 4.
Check the wiring between OSSD 4 and the load, and whether the load is broken or not.
Output Over Current Error (in total)
Total amount of current on each output exceeds the specification.
Check the wiring between each output and the load, and whether the load is broken or not.
Check if the total amount of current is within the specification.
Muting Lamp Error (Disconnection)
There is a problem where the muting lamp is connected to the muting lamp output. (The muting lamp is disconnected or it is broken.)
Please check the following:
Muting Lamp Error (Overcurrent)
The muting lamp connected to the muting lamp output has an overcurrent exceeding the rated current.
Please check the following:
EDM error
EDM error
Bank Input Error
Bank Sequence Error
The bank switching was not performed according to the specified bank sequence.
Check the bank sequence and the configuration of bank sequence monitoring.
Encoder velocity error
The encoder velocity exceeds the set velocity range.
Ensure that the encoder velocity does not exceed the velocity range.
Encoder Pulse Frequency Error (Ch,1)
The input of Encoder Input 1 exceeds the maximum pulse frequency (100 kHz).
Ensure that the output from the encoder does not exceed the maximum pulse frequency.
Encoder Pulse Frequency Error (Ch,2)
The input of Encoder Input 2 exceeds the maximum pulse frequency (100 kHz).
Ensure that the output from the encoder does not exceed the maximum pulse frequency.
Encoder Mismatch Error
Encoder Input Error (Ch.1)
Wiring of encoder input 1 is incorrect.
Check the encoder input wiring.
Encoder Input Error (Ch.2)
Wiring of encoder input 2 is incorrect.
Check the encoder input wiring.
Communication Error
Communication Error
Unused Wiring Error (Input 2)
Input 2 is set as unused but is not in an open circuit.
If Input 2 is set to unused, make an open circuit on Input 2 with insulation.
Unused Wiring Error (Input 6)
Input 6 is set as unused but is not in an open circuit.
If Input 6 is set to unused, make an open circuit on Input 6 with insulation.
Configuration Error (Type)
The display unit type does not match the settings in the system memory.
Check the display unit type.
Configuration Error (Head)
The number of scanner heads does not match the settings in the system memory.
Check the number of scanner heads.
System Memory Error (Data)
System Configuration Error (Display unit)
The Display unit is paired to another system memory.
Transfer new settings from the SZ Configurator again, or delete the system configuration information. For details of clearing system configuration information, see “SZ-V Series User’s Manual”.
System Configuration Error (Head 1)
Scanner head 1 is paired to another system memory.
Transfer new settings from the SZ Configurator again, or delete the system configuration information. For details of clearing system configuration information, see “SZ-V Series User’s Manual”.
System Configuration Error (Head 2)
Scanner head 2 is paired to another system memory.
Transfer new settings from the SZ Configurator again, or delete the system configuration information. For details of clearing system configuration information, see “SZ-V Series User’s Manual”.
System Configuration Error (Head 3)
Scanner head 3 is paired to another system memory.
Transfer new settings from the SZ Configurator again, or delete the system configuration information. For details of clearing system configuration information, see “SZ-V Series User’s Manual”.
Window Calibration Error
Window Calibration Error
Window Calibration Error