Main Unit Model: GS-M50N
NPN
            | OSSD operation | Open/close link mode | 
|---|---|
| Interlock function | Automatic only | 
| EDM function | N/A | 
| Applicable model | Main unit | 
|---|---|
| Hinged door, terminal block | GS-M50N | 
 
            | Required | Pin | Color | Icon above | Function | 
|---|---|---|---|---|
|  | 1 | Brown |  | +24 V | 
|  | 5 | Blue |  | 0 V | 
|  | 6 | Black |  | OSSD1 | 
|  | 7 | White |  | OSSD2 | 
|  | 2 | Red/black |  | Safety input 1 | 
|  | 3 | Red/white |  | Safety input 2 | 
|  | 8 | Gray |  | OSSD operation switching input | 
| 4 | Light blue |  | Lock control input | 
- The required wiring ensures that the unit can be operated without entering the error state.
- The icons in the above figure match the wire colors of the connector type. You do not have to use wires of the same colors.
 
        