Compact Laser Sensor
LR-X series
Specs Compact Laser Sensor LR-X series
Standard Model, Cable Type
Model |
LR-X50 |
LR-X100 |
LR-X250 |
|||
Image |
|
|
|
|||
Type |
Cable Type |
|||||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
25.0 to 100.0 mm 0.98" to 3.94" |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
1.0 mm 0.04" |
30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" |
|||
Display Resolution |
0.1 mm 0.004" |
1 to 2 mm 0.04" to 0.08" |
||||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
Approx. 0.3 mm × 2 mm 0.012" × 0.08" |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
|||||
Light Source |
Type |
Green laser (505 nm) |
||||
Laser Class |
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2) |
|||||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||||
I/O |
Control Output |
NPN open collector/PNP open collector, N.O./N.C selectable. *3 |
||||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *3 |
|||||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, |
|||||
Power supply |
Power voltage |
16 to 30 VDC (including 10% ripple (P-P) or less), class 2 |
||||
Power consumption |
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) |
|||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||
Ambient light |
Incandescent lamp: 16000 lux or less |
Incandescent lamp: 8000 lux or less |
||||
Ambient temperature |
-10°C to +50°C 14°F to + 122°F (no freezing) |
|||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||||
Shock resistance |
1000 m/s2 (100G) 6 times each for X, Y, and Z axes |
|||||
Material |
Head Case: SUS316L; Head Lens Cover: PSU |
|||||
Accessories |
Instruction manual, laser warning label |
|||||
Weight |
Approx. 90 g |
|||||
*1 If 500 µs is selected, the following limitations apply. |
Standard Model, M8 Connector Type
Model |
LR-X50C |
LR-X100C |
LR-X250C |
|||
Image |
|
|
|
|||
Type |
M8 Connector Type*1 |
|||||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
25.0 to 100.0 mm 0.98" to 3.94" |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
1.0 mm 0.04" |
30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" |
|||
Display Resolution |
0.1 mm 0.004" |
1 to 2 mm 0.04" to 0.08" |
||||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
Approx. 0.3 mm × 2 mm 0.012" × 0.08" |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Response Time |
500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable |
|||||
Light Source |
Type |
Green laser (505 nm) |
||||
Laser Class |
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3) |
|||||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||||
I/O |
Control Output |
NPN open collector/PNP open collector, N.O./N.C selectable. *4 |
||||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 |
|||||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, |
|||||
Power supply |
Power voltage |
16 to 30 VDC (including 10% ripple (P-P) or less), class 2 |
||||
Power consumption |
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) |
|||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||
Ambient light |
Incandescent lamp: 16000 lux or less |
Incandescent lamp: 8000 lux or less |
||||
Ambient temperature |
-10°C to +50°C 14°F to + 122°F (no freezing) |
|||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||||
Shock resistance |
1000 m/s2 (100G) 6 times each for X, Y, and Z axes |
|||||
Material |
Head Case: SUS316L; Head Lens Cover: PSU |
|||||
Accessories |
Instruction manual, laser warning label |
|||||
Weight |
Approx. 35 g |
|||||
*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link. |
Standard Model, M8 Connector Type (Guarded Cable)
Model |
LR-X50CG |
LR-X100CG |
LR-X250CG |
|||
Image |
|
|
|
|||
Type |
M8 Connector Type*1 |
|||||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
25.0 to 100.0 mm 0.98" to 3.94" |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
1.0 mm 0.04" |
30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" |
|||
Display Resolution |
0.1 mm 0.004" |
1 to 2 mm 0.04" to 0.08" |
||||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
Approx. 0.3 mm × 2 mm 0.012" × 0.08" |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Response Time |
500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable |
|||||
Light Source |
Type |
Green laser (505 nm) |
||||
Laser Class |
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3) |
|||||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||||
I/O |
Control Output |
NPN open collector/PNP open collector, N.O./N.C selectable. *4 |
||||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 |
|||||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, |
|||||
Power supply |
Power voltage |
16 to 30 VDC (including 10% ripple (P-P) or less), class 2 |
||||
Power consumption |
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) |
|||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||
Ambient light |
Incandescent lamp: 16000 lux or less |
Incandescent lamp: 8000 lux or less |
||||
Ambient temperature |
-10°C to +50°C 14°F to + 122°F (no freezing) |
|||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||||
Shock resistance |
1000 m/s2 (100G) 6 times each for X, Y, and Z axes |
|||||
Material |
Head Case: SUS316L; Head Lens Cover: PSU |
|||||
Accessories |
Instruction manual, laser warning label |
|||||
Weight |
Approx. 45 g |
|||||
*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link. |
Separate Amplifier Model, Sensor Head, 2m Cable
Model |
LR-XH50 |
LR-XH100 |
LR-XH250 |
|||
Image |
|
|
|
|||
Type |
Cable Length: 2 m 6.6' |
|||||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
25.0 to 100.0 mm 0.98" to 3.94" |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
1.0 mm 0.04" |
30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm |
|||
Display Resolution |
0.1 mm 0.004" |
1 to 2 mm 0.04" to 0.08" |
||||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
Approx. 0.3 mm × 2 mm 0.012" × 0.08" |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Light Source |
Type |
Green laser (505 nm) |
||||
Laser Class |
Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1) |
|||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||
Ambient light |
Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less |
Incandescent lamp: 8000 lux or less, Sunlight: 8000 lux or less |
||||
Ambient temperature |
-10°C to +50°C 14°F to 122°F (no freezing) |
|||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||||
Shock resistance |
1000 m/s2 (100G); 6 times each for X, Y, and Z axes |
|||||
Material |
Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable) |
|||||
Accessories |
Laser warning label |
|||||
Weight |
approx. 75 g |
|||||
*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56. |
Separate Amplifier Model, Sensor Head, 10m Cable
Model |
LR-XH50(10M) |
LR-XH100(10M) |
LR-XH250(10M) |
|||
Image |
|
|
|
|||
Type |
Cable Length: 10 m 32.8' |
|||||
Detecting Distance |
25.0 to 50.0 mm 0.98" to 1.97" |
25.0 to 100.0 mm 0.98" to 3.94" |
30 to 250 mm 1.18" to 9.84" |
|||
Standard Detectable Deviation |
0.5 mm 0.02" |
1.0 mm 0.04" |
30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm |
|||
Display Resolution |
0.1 mm 0.004" |
1 to 2 mm 0.04" to 0.08" |
||||
Spot Size |
Approx. 0.2 mm × 1.5 mm 0.008" × 0.06" |
Approx. 0.3 mm × 2 mm 0.012" × 0.08" |
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" |
|||
Light Source |
Type |
Green laser (505 nm) |
||||
Laser Class |
Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1) |
|||||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||||
Ambient light |
Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less |
Incandescent lamp: 8000 lux or less, Sunlight: 8000 lux or less |
||||
Ambient temperature |
-10°C to +50°C 14°F to 122°F (no freezing) |
|||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes |
|||||
Shock resistance |
1000 m/s2 (100G); 6 times each for X, Y, and Z axes |
|||||
Material |
Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable) |
|||||
Accessories |
Laser warning label, sensor head connector |
|||||
Weight |
approx. 250 g |
|||||
*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56. |
Separate Amplifier Model, Amplifier Units Cable Type NPN
Model |
LR-XN11N |
LR-XN12N |
|||
Image |
|
|
|||
Type |
NPN Output |
||||
Cable/Connector |
Cable |
||||
Main Unit/Expansion Unit |
Main Unit |
Expansion Unit |
|||
No. of Control Outputs |
2 |
||||
No. of External Inputs |
1 |
||||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
||||
IO-Link |
— |
||||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
|||
I/O |
Control Output |
Open collector, 30 VDC or lower, N.O./N.C. |
|||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable |
||||
Unit Expansion |
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. |
||||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
||||
Number of Interference Prevention Devices |
OFF/4 units/8 units selectable*2 |
||||
Power supply |
Power voltage |
16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2 |
|||
Power consumption |
During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V) (excluding Load Current) |
||||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*4 |
|||
Relative humidity |
35 to 85% RH (no condensation) |
||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
||||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
||||
Case Material |
Main Unit and Cover: Polycarbonate |
||||
Accessories |
Instruction manual |
||||
Weight |
Approx. 80 g |
Approx. 70 g |
|||
*1 If 500 µs is selected, the following limitations apply. |
Separate Amplifier Model, Amplifier Units Cable Type PNP
Model |
LR-XN11P |
LR-XN12P |
|||
Image |
|
|
|||
Type |
PNP Output |
||||
Cable/Connector |
Cable |
||||
Main Unit/Expansion Unit |
Main Unit |
Expansion Unit |
|||
No. of Control Outputs |
2 |
||||
No. of External Inputs |
1 |
||||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
||||
IO-Link |
— |
||||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
|||
I/O |
Control Output |
Open collector, 30 VDC or lower, N.O./N.C. |
|||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable |
||||
Unit Expansion |
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. |
||||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
||||
Number of Interference Prevention Devices |
OFF/4 units/8 units selectable*2 |
||||
Power supply |
Power voltage |
16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2 |
|||
Power consumption |
During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current) |
||||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*4 |
|||
Relative humidity |
35 to 85% RH (no condensation) |
||||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
||||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
||||
Case Material |
Main Unit and Cover: Polycarbonate |
||||
Accessories |
Instruction manual |
||||
Weight |
Approx. 80 g |
Approx. 70 g |
|||
*1 If 500 µs is selected, the following limitations apply. |
Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type)
Model |
LR-XN11C |
|||
Image |
|
|||
Type |
NPN Output/PNP Output (Selectable output) |
|||
Cable/Connector |
M8 connector*1 |
|||
Main Unit/Expansion Unit |
Main Unit (expansion not possible) |
|||
No. of Control Outputs |
2*2 |
|||
No. of External Inputs |
1*2 |
|||
Response Time |
500 µs*3/1 ms/3 ms/10 ms/200 ms Selectable |
|||
IO-Link |
Specification v1.1/COM2 (38.4 kbps) |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
Open collector, 30 VDC or lower, N.O./N.C. |
||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable |
|||
Unit Expansion |
— |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
|||
Number of Interference Prevention Devices |
— |
|||
Power supply |
Power voltage |
16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*5 |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
|||
Case Material |
Main Unit and Cover: Polycarbonate |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 22 g |
|||
*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link. |
Separate Amplifier Model, Amplifier Units Expansion unit (Zero Line Type)
Model |
LR-XN10 |
|||
Image |
|
|||
Type |
— |
|||
Cable/Connector |
||||
Main Unit/Expansion Unit |
Expansion Unit |
|||
No. of Control Outputs |
None*1 |
|||
No. of External Inputs |
— |
|||
Response Time |
500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable |
|||
IO-Link |
— |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
— |
||
External Input |
||||
Unit Expansion |
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
|||
Number of Interference Prevention Devices |
OFF/4 units/8 units selectable*3 |
|||
Power supply |
Power voltage |
16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V) |
|||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*5 |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
|||
Case Material |
Main Unit and Cover: Polycarbonate |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 21 g |
|||
*1 This counts as 1 output when expanding with multiple units to the FS-MC8N/MC8P and NU Series. |