Separate Amplifier Digital Proximity Sensor
ER-N series
Specs Separate Amplifier Digital Proximity Sensor ER-N series
Sensor head Shielded type Cylindrical type
|
Model |
ER-NH028 |
ER-NH038 |
ER-NH054 |
ER-NH054G |
ER-NH080 |
ER-NH080G |
|||
|
Image |
|
|
|
|
|
|
|||
|
Cable |
Standard |
Stainless steel |
Standard |
Stainless steel |
|||||
|
Stable detection range |
0 to 0.6 mm |
0 to 0.8 mm |
0 to 1 mm 0 to 0.04" *1 *2 |
0 to 2 mm 0 to 0.08" *1 *2 |
|||||
|
Maximum operating distance |
1.2 mm 0.05" *1 *3 |
2 mm 0.08" *1 *3 |
3 mm 0.12" *1 *3 |
5 mm 0.20" *1 *3 |
|||||
|
Hysteresis distance |
Adjustable |
||||||||
|
Repeatability |
1 μm 0.04 Mil *1 *4 |
2 μm 0.08 Mil *1 *4 |
|||||||
|
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
||||||||
|
Standard detectable object (Iron, t = 1 mm 0.04") |
5 × 5 mm 0.20" × 0.20" |
10 × 10 mm 0.39" × 0.39" |
|||||||
|
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F) |
||||||||
|
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
|||||||
|
Ambient temperature |
-10 to +60°C 14°F to 140°F (no freezing) |
||||||||
|
Relative humidity |
Up to 85% RH (No condensation) |
||||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
||||||||
|
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
||||||||
|
Material |
Detection surface |
Epoxy resin |
PVC |
Phenol resin |
|||||
|
Case |
SUS304 |
||||||||
|
Cable |
PVC |
Cable: PVC |
PVC |
Cable: PVC |
|||||
|
Sensor head connector |
PA66, polycarbonate |
||||||||
|
Accessories |
― |
||||||||
|
Accessories |
|||||||||
|
Weight |
Approx. 30 g |
Approx. 40 g |
Approx. 60 g |
Approx. 85 g |
Approx. 60 g |
Approx. 90 g |
|||
|
*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object. |
|||||||||
Sensor head Shielded type Screw/Thin/Unshielded Cylindrical type
|
Model |
ER-NH100 |
ER-NH100G |
ER-NH035F |
ER-NH048F |
ER-NH028U |
|||
|
Image |
|
|
|
|
|
|||
|
Cable |
Standard |
Stainless steel |
Standard |
|||||
|
Stable detection range |
0 to 2 mm 0 to 0.08" *1 *2 |
0 to 1 mm |
0 to 5 mm |
0 to 3 mm |
||||
|
Maximum operating distance |
5 mm 0.20" *1 *3 |
3 mm 0.12" *1 *3 |
8 mm 0.31" *1 *3 |
7 mm 0.28" *1 *3 |
||||
|
Hysteresis distance |
Adjustable |
|||||||
|
Repeatability |
2 μm 0.08 Mil *1 *4 |
1 μm 0.04 Mil *1 *4 |
2 μm 0.08 Mil *1 *4 |
|||||
|
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||||||
|
Standard detectable object (Iron, t = 1 mm 0.04") |
10 × 10 mm 0.39" × 0.39" |
5 × 5 mm |
15 × 15 mm |
10 × 10 mm |
||||
|
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (0 to +50°C 32°F to 122°F) |
|||||||
|
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||||||
|
Ambient temperature |
-10 to +60°C 14°F to 140°F (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (No condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||||||
|
Material |
Detection surface |
Phenol resin |
Epoxy resin |
Ceramic |
||||
|
Case |
Chrome-plated |
SUS304 |
SUS303 |
SUS304 |
||||
|
Cable |
PVC |
Cable: PVC |
PVC |
|||||
|
Sensor head connector |
PA66, polycarbonate |
|||||||
|
Accessories |
Nut: Chrome-plated brass |
M2 screw/nut/spring washer/ |
― |
|||||
|
Accessories |
M10 nut × 2 |
M2 screw/nut/ |
||||||
|
Weight |
Approx. 65 g |
Approx. 100 g |
Approx. 40 g |
Approx. 65 g |
Approx. 35 g |
|||
|
*1 The stable detection range, maximum operating distance, repeatability, and temperature characteristics are values for when the operation mode is set to “Normal” using a standard detection object. |
||||||||
Amplifier unit
|
Model |
ER-N11 |
ER-N12 |
ER-N11C *6 |
ER-N10 |
|||
|
Image |
|
|
|
|
|||
|
Type |
Separate amplifier Amplifier unit Main unit (cable type) |
Separate amplifier Amplifier unit Expansion unit (cable type) |
Separate amplifier Amplifier unit Main unit (expansion not supported) (M8 connector type) *7 |
Separate amplifier Amplifier unit Expansion unit (zero line type) |
|||
|
No. of control outputs |
2 |
2 *8 |
None *9 |
||||
|
No. of external inputs |
1 |
1 *8 |
― |
||||
|
Temperature characteristics |
±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *1 |
||||||
|
Response time |
150 μs *2/ 300 μs *2/ 1 ms / 4 ms / 16 ms / 64 ms (switchable) |
||||||
|
Network compatibility |
― |
NU Series |
IO-Link (Specification v1.1/COM2 (38.4 kbps)) |
NU Series |
|||
|
Function |
Operation mode |
Normal / Magnetic metal / Non-magnetic metal / Hybrid |
|||||
|
Timer function |
Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot |
||||||
|
I/O |
Control output |
Open-collector, 30 VDC or less, PNP/NPN switchable |
|||||
|
External input |
Tuning / Detection stop / Zero shift / Hold value reset (switchable) |
||||||
|
Additional expansion units |
Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device |
― |
Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device |
||||
|
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
||||||
|
No. of mutual interference prevention units |
OFF / 4 units / 8 units (selectable) *3 |
― |
OFF / 4 units / 8 units (selectable) *3 |
||||
|
Power supply |
Power voltage |
18 to 30 VDC *4 (including 10% or less ripple (P-P)), Class 2 |
|||||
|
Power consumption (excluding load current) |
1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V) |
830 mW or less |
|||||
|
Environmental resistance |
Ambient temperature |
Operation: -25 to +55°C -13°F to +131°F *5, Storage: -30 to 70°C -22°F to +158°F (no freezing) |
|||||
|
Relative humidity |
Operation/storage: Up to 85% RH (no condensation) |
||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
||||||
|
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
||||||
|
Case material |
Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass |
||||||
|
Accessories |
Instruction manual |
||||||
|
Weight |
Approx. 90 g 3.18 oz |
Approx. 55 g 1.94 oz |
Approx. 50 g 1.77 oz |
||||
|
*1 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range. |
|||||||