Safety Light Curtain
SL-V series
Specs Safety Light Curtain SL-V series
| 
         Model  | 
        
         SL-V23F  | 
        
         SL-V31F  | 
        
         SL-V39F  | 
        
         SL-V47F  | 
        
         SL-V55F  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         9.1*1  | 
        
         10.2*1  | 
        
         11.3*1  | 
        
         12.4*1  | 
        
         13.5*1  | 
    ||
| 
         OFF→ON  | 
        
         49.1*1  | 
        
         50.2*1  | 
        
         51.3*1  | 
        
         52.4*1  | 
        
         53.5*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN61000-6-2, EN55011 Class A, FCC Part15B Class A  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         83*6  | 
        
         93*6  | 
        
         103*6  | 
        
         112*6  | 
        
         121*6  | 
    |
| 
         Receiver  | 
        
         78*6  | 
        
         80*6  | 
        
         82*6  | 
        
         85*6  | 
        
         87*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         80*6  | 
        
         90*6  | 
        
         99*6  | 
        
         107*6  | 
        
         115*6  | 
    ||
| 
         Receiver  | 
        
         74*6  | 
        
         75*6  | 
        
         77*6  | 
        
         78*6  | 
        
         80*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         200 g  | 
        
         270 g  | 
        
         330 g  | 
        
         390 g  | 
        
         450 g  | 
    ||
| 
         Receiver  | 
        
         205 g  | 
        
         275 g  | 
        
         345 g  | 
        
         405 g  | 
        
         465 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V63F  | 
        
         SL-V71F  | 
        
         SL-V79F  | 
        
         SL-V87F  | 
        
         SL-V95F  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         14.6*1  | 
        
         15.7*1  | 
        
         16.8*1  | 
        
         17.9*1  | 
        
         19*1  | 
    ||
| 
         OFF→ON  | 
        
         54.6*1  | 
        
         55.7*1  | 
        
         56.8*1  | 
        
         57.9*1  | 
        
         59*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         129*6  | 
        
         136*6  | 
        
         142*6  | 
        
         148*6  | 
        
         154*6  | 
    |
| 
         Receiver  | 
        
         89*6  | 
        
         92*6  | 
        
         94*6  | 
        
         97*6  | 
        
         99*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         122*6  | 
        
         129*6  | 
        
         135*6  | 
        
         140*6  | 
        
         145*6  | 
    ||
| 
         Receiver  | 
        
         82*6  | 
        
         83*6  | 
        
         85*6  | 
        
         87*6  | 
        
         88*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         510 g  | 
        
         570 g  | 
        
         620 g  | 
        
         670 g  | 
        
         720 g  | 
    ||
| 
         Receiver  | 
        
         525 g  | 
        
         585 g  | 
        
         635 g  | 
        
         685 g  | 
        
         735 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V103F  | 
        
         SL-V111F  | 
        
         SL-V119F  | 
        
         SL-V127F  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         20.1*1  | 
        
         21.2*1  | 
        
         22.3*1  | 
        
         23.4*1  | 
    ||
| 
         OFF→ON  | 
        
         60.1*1  | 
        
         61.2*1  | 
        
         62.3*1  | 
        
         63.4*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         159*6  | 
        
         163*6  | 
        
         166*6  | 
        
         169*6  | 
    |
| 
         Receiver  | 
        
         101*6  | 
        
         104*6  | 
        
         106*6  | 
        
         109*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         149*6  | 
        
         152*6  | 
        
         156*6  | 
        
         158*6  | 
    ||
| 
         Receiver  | 
        
         90*6  | 
        
         92*6  | 
        
         93*6  | 
        
         95*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         760 g  | 
        
         810 g  | 
        
         850 g  | 
        
         890 g  | 
    ||
| 
         Receiver  | 
        
         775 g  | 
        
         815 g  | 
        
         855 g  | 
        
         895 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V23FM  | 
        
         SL-V31FM  | 
        
         SL-V39FM  | 
        
         SL-V47FM  | 
        
         SL-V55FM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         9.1*1  | 
        
         10.2*1  | 
        
         11.3*1  | 
        
         12.4*1  | 
        
         13.5*1  | 
    ||
| 
         OFF→ON  | 
        
         49.1*1  | 
        
         50.2*1  | 
        
         51.3*1  | 
        
         52.4*1  | 
        
         53.5*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         83*6  | 
        
         93*6  | 
        
         103*6  | 
        
         112*6  | 
        
         121*6  | 
    |
| 
         Receiver  | 
        
         78*6  | 
        
         80*6  | 
        
         82*6  | 
        
         85*6  | 
        
         87*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         80*6  | 
        
         90*6  | 
        
         99*6  | 
        
         107*6  | 
        
         115*6  | 
    ||
| 
         Receiver  | 
        
         74*6  | 
        
         75*6  | 
        
         77*6  | 
        
         78*6  | 
        
         80*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         670 g  | 
        
         830 g  | 
        
         990 g  | 
        
         1,150 g  | 
        
         1,300 g  | 
    ||
| 
         Receiver  | 
        
         680 g  | 
        
         840 g  | 
        
         1,000 g  | 
        
         1,160 g  | 
        
         1,320 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V63FM  | 
        
         SL-V71FM  | 
        
         SL-V79FM  | 
        
         SL-V87FM  | 
        
         SL-V95FM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         14.6*1  | 
        
         15.7*1  | 
        
         16.8*1  | 
        
         17.9*1  | 
        
         19*1  | 
    ||
| 
         OFF→ON  | 
        
         54.6*1  | 
        
         55.7*1  | 
        
         56.8*1  | 
        
         57.9*1  | 
        
         59*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         129*6  | 
        
         136*6  | 
        
         142*6  | 
        
         148*6  | 
        
         154*6  | 
    |
| 
         Receiver  | 
        
         89*6  | 
        
         92*6  | 
        
         94*6  | 
        
         97*6  | 
        
         99*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         122*6  | 
        
         129*6  | 
        
         135*6  | 
        
         140*6  | 
        
         145*6  | 
    ||
| 
         Receiver  | 
        
         82*6  | 
        
         83*6  | 
        
         85*6  | 
        
         87*6  | 
        
         88*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         1,460 g  | 
        
         1,610 g  | 
        
         1,760 g  | 
        
         1,900 g  | 
        
         2,050 g  | 
    ||
| 
         Receiver  | 
        
         1,470 g  | 
        
         1,630 g  | 
        
         1,770 g  | 
        
         1,910 g  | 
        
         2,060 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V103FM  | 
        
         SL-V111FM  | 
        
         SL-V119FM  | 
        
         SL-V127FM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.55" ø14 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         10 mm/ø4 mm 0.39"/ø0.16"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         20.1*1  | 
        
         21.2*1  | 
        
         22.3*1  | 
        
         23.4*1  | 
    ||
| 
         OFF→ON  | 
        
         60.1*1  | 
        
         61.2*1  | 
        
         62.3*1  | 
        
         63.4*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         159*6  | 
        
         163*6  | 
        
         166*6  | 
        
         169*6  | 
    |
| 
         Receiver  | 
        
         101*6  | 
        
         104*6  | 
        
         106*6  | 
        
         109*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         149*6  | 
        
         152*6  | 
        
         156*6  | 
        
         158*6  | 
    ||
| 
         Receiver  | 
        
         90*6  | 
        
         92*6  | 
        
         93*6  | 
        
         95*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         2,190 g  | 
        
         2,330 g  | 
        
         2,470 g  | 
        
         2,590 g  | 
    ||
| 
         Receiver  | 
        
         2,200 g  | 
        
         2,460 g  | 
        
         2,600 g  | 
    ||||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V08H  | 
        
         SL-V12H  | 
        
         SL-V16H  | 
        
         SL-V20H  | 
        
         SL-V24H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         7*1  | 
        
         7.6*1  | 
        
         8.1*1  | 
        
         8.7*1  | 
        
         9.2*1  | 
    ||
| 
         OFF→ON  | 
        
         47*1  | 
        
         47.6*1  | 
        
         48.1*1  | 
        
         48.7*1  | 
        
         49.2*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         56*6  | 
        
         63*6  | 
        
         69*6  | 
        
         75*6  | 
        
         81*6  | 
    |
| 
         Receiver  | 
        
         70*6  | 
        
         72*6  | 
        
         74*6  | 
        
         77*6  | 
    ||||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         52*6  | 
        
         58*6  | 
        
         64*6  | 
        
         70*6  | 
        
         76*6  | 
    ||
| 
         Receiver  | 
        
         65*6  | 
        
         66*6  | 
        
         67*6  | 
        
         68*6  | 
        
         69*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         150 g  | 
        
         200 g  | 
        
         250 g  | 
        
         300 g  | 
        
         350 g  | 
    ||
| 
         Receiver  | 
        
         155 g  | 
        
         205 g  | 
        
         265 g  | 
        
         315 g  | 
        
         365 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V28H  | 
        
         SL-V32H  | 
        
         SL-V36H  | 
        
         SL-V40H  | 
        
         SL-V44H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         9.8*1  | 
        
         10.3*1  | 
        
         10.9*1  | 
        
         11.4*1  | 
        
         12*1  | 
    ||
| 
         OFF→ON  | 
        
         49.8*1  | 
        
         50.3*1  | 
        
         50.9*1  | 
        
         51.4*1  | 
        
         52*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         87*6  | 
        
         93*6  | 
        
         98*6  | 
        
         103*6  | 
        
         108*6  | 
    |
| 
         Receiver  | 
        
         79*6  | 
        
         80*6  | 
        
         82*6  | 
        
         84*6  | 
        
         85*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         81*6  | 
        
         86*6  | 
        
         91*6  | 
        
         96*6  | 
        
         100*6  | 
    ||
| 
         Receiver  | 
        
         69*6  | 
        
         70*6  | 
        
         71*6  | 
        
         72*6  | 
        
         73*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         400 g  | 
        
         450 g  | 
        
         500 g  | 
        
         550 g  | 
        
         600 g  | 
    ||
| 
         Receiver  | 
        
         415 g  | 
        
         465 g  | 
        
         515 g  | 
        
         575 g  | 
        
         625 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V48H  | 
        
         SL-V52H  | 
        
         SL-V56H  | 
        
         SL-V60H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         12.5*1  | 
        
         13.1*1  | 
        
         13.6*1  | 
        
         14.2*1  | 
    ||
| 
         OFF→ON  | 
        
         52.5*1  | 
        
         53.1*1  | 
        
         53.6*1  | 
        
         54.2*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         113*6  | 
        
         117*6  | 
        
         122*6  | 
        
         126*6  | 
    |
| 
         Receiver  | 
        
         87*6  | 
        
         88*6  | 
        
         90*6  | 
        
         91*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         104*6  | 
        
         109*6  | 
        
         112*6  | 
        
         116*6  | 
    ||
| 
         Receiver  | 
        
         74*6  | 
        
         75*6  | 
        
         76*6  | 
    ||||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         650 g  | 
        
         700 g  | 
        
         750 g  | 
        
         800 g  | 
    ||
| 
         Receiver  | 
        
         675 g  | 
        
         725 g  | 
        
         775 g  | 
        
         835 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V64H  | 
        
         SL-V72H  | 
        
         SL-V80H  | 
        
         SL-V88H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
        
         0.1 to 7 m  | 
    |||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         14.7*1  | 
        
         15.8*1  | 
        
         16.9*1  | 
        
         18*1  | 
    ||
| 
         OFF→ON  | 
        
         54.7*1  | 
        
         55.8*1  | 
        
         56.9*1  | 
        
         58*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         130*6  | 
        
         137*6  | 
        
         144*6  | 
        
         149*6  | 
    |
| 
         Receiver  | 
        
         93*6  | 
        
         96*6  | 
        
         98*6  | 
        
         101*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         120*6  | 
        
         126*6  | 
        
         132*6  | 
        
         136*6  | 
    ||
| 
         Receiver  | 
        
         77*6  | 
        
         78*6  | 
        
         80*6  | 
        
         81*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         860 g  | 
        
         960 g  | 
        
         1,060 g  | 
        
         1,160 g  | 
    ||
| 
         Receiver  | 
        
         885 g  | 
        
         985 g  | 
        
         1,095 g  | 
        
         1,195 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V96H  | 
        
         SL-V104H  | 
        
         SL-V112H  | 
        
         SL-V120H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         19.1*1  | 
        
         20.2*1  | 
        
         21.3*1  | 
        
         22.4*1  | 
    ||
| 
         OFF→ON  | 
        
         59.1*1  | 
        
         60.2*1  | 
        
         61.3*1  | 
        
         62.4*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         154*6  | 
        
         159*6  | 
        
         162*6  | 
        
         165*6  | 
    |
| 
         Receiver  | 
        
         104*6  | 
        
         107*6  | 
        
         109*6  | 
        
         112*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         140*6  | 
        
         143*6  | 
        
         146*6  | 
        
         147*6  | 
    ||
| 
         Receiver  | 
        
         83*6  | 
        
         84*6  | 
        
         86*6  | 
        
         87*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         1,260 g  | 
        
         1,360 g  | 
        
         1,460 g  | 
        
         1,570 g  | 
    ||
| 
         Receiver  | 
        
         1,295 g  | 
        
         1,405 g  | 
        
         1,505 g  | 
        
         1,615 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V12HM  | 
        
         SL-V16HM  | 
        
         SL-V20HM  | 
        
         SL-V24HM  | 
        
         SL-V28HM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         7.6*1  | 
        
         8.1*1  | 
        
         8.7*1  | 
        
         9.2*1  | 
        
         9.8*1  | 
    ||
| 
         OFF→ON  | 
        
         47.6*1  | 
        
         48.1*1  | 
        
         48.7*1  | 
        
         49.2*1  | 
        
         49.8*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         63*6  | 
        
         69*6  | 
        
         75*6  | 
        
         81*6  | 
        
         87*6  | 
    |
| 
         Receiver  | 
        
         72*6  | 
        
         74*6  | 
        
         77*6  | 
        
         79*6  | 
    ||||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         58*6  | 
        
         64*6  | 
        
         70*6  | 
        
         76*6  | 
        
         81*6  | 
    ||
| 
         Receiver  | 
        
         66*6  | 
        
         67*6  | 
        
         68*6  | 
        
         69*6  | 
    ||||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         670 g  | 
        
         810 g  | 
        
         960 g  | 
        
         1,110 g  | 
        
         1,250 g  | 
    ||
| 
         Receiver  | 
        
         680 g  | 
        
         830 g  | 
        
         970 g  | 
        
         1,120 g  | 
        
         1,270 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V32HM  | 
        
         SL-V36HM  | 
        
         SL-V40HM  | 
        
         SL-V44HM  | 
        
         SL-V48HM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    |||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    |||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    |||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    |||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         10.3*1  | 
        
         10.9*1  | 
        
         11.4*1  | 
        
         12*1  | 
        
         12.5*1  | 
    ||
| 
         OFF→ON  | 
        
         50.3*1  | 
        
         50.9*1  | 
        
         51.4*1  | 
        
         52*1  | 
        
         52.5*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    |||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    |||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    ||||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    |||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    |||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    |||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    |||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    |||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    ||||||
| 
         Interlock-reset-ready output  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Clear/blocked output  | 
    ||||||||
| 
         State information output 1, 2  | 
    ||||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    |||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    ||||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    |||||||
| 
         Reset input  | 
    ||||||||
| 
         Muting input 1, 2  | 
    ||||||||
| 
         Override input  | 
    ||||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    |||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    |||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    |||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    |||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    ||||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         93*6  | 
        
         98*6  | 
        
         103*6  | 
        
         108*6  | 
        
         113*6  | 
    |
| 
         Receiver  | 
        
         80*6  | 
        
         82*6  | 
        
         84*6  | 
        
         85*6  | 
        
         87*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         86*6  | 
        
         91*6  | 
        
         96*6  | 
        
         100*6  | 
        
         104*6  | 
    ||
| 
         Receiver  | 
        
         70*6  | 
        
         71*6  | 
        
         72*6  | 
        
         73*6  | 
        
         74*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    ||||||
| 
         Overvoltage category  | 
        
         II  | 
    |||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    |||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    ||||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    |||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    |||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         1,400 g  | 
        
         1,540 g  | 
        
         1,690 g  | 
        
         1,830 g  | 
        
         1,980 g  | 
    ||
| 
         Receiver  | 
        
         1,410 g  | 
        
         1,560 g  | 
        
         1,710 g  | 
        
         1,850 g  | 
        
         2,000 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    ||||||||
| 
         Model  | 
        
         SL-V52HM  | 
        
         SL-V56HM  | 
        
         SL-V60HM  | 
        
         SL-V64HM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 9 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         13.1*1  | 
        
         13.6*1  | 
        
         14.2*1  | 
        
         14.7*1  | 
    ||
| 
         OFF→ON  | 
        
         53.1*1  | 
        
         53.6*1  | 
        
         54.2*1  | 
        
         54.7*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         117*6  | 
        
         122*6  | 
        
         126*6  | 
        
         130*6  | 
    |
| 
         Receiver  | 
        
         88*6  | 
        
         90*6  | 
        
         91*6  | 
        
         93*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         109*6  | 
        
         112*6  | 
        
         116*6  | 
        
         120*6  | 
    ||
| 
         Receiver  | 
        
         74*6  | 
        
         75*6  | 
        
         76*6  | 
        
         77*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         2,130 g  | 
        
         2,270 g  | 
        
         2,420 g  | 
        
         2,560 g  | 
    ||
| 
         Receiver  | 
        
         2,150 g  | 
        
         2,290 g  | 
        
         2,440 g  | 
        
         2,590 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-V72HM  | 
        
         SL-V80HM  | 
        
         SL-V88HM  | 
        
         SL-V96HM  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Detection capability  | 
        
         ø0.98" ø25 mm  | 
    ||||||
| 
         Beam axis spacing/Lens diameter  | 
        
         20 mm/ø5 mm 0.79"/ø0.20"  | 
    ||||||
| 
         Effective aperture angle  | 
        
         Max. ±2.5 ° (When operating distance is 3 m 98.23' or more)  | 
    ||||||
| 
         Working distance  | 
        
         0.1 to 7 m  | 
    ||||||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         15.8*1  | 
        
         16.9*1  | 
        
         18*1  | 
        
         19.1*1  | 
    ||
| 
         OFF→ON  | 
        
         55.8*1  | 
        
         56.9*1  | 
        
         58*1  | 
        
         59.1*1  | 
    |||
| 
         Light source  | 
        
         Infrared LED (850 nm)  | 
    ||||||
| 
         Operation mode  | 
        
         Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | 
    ||||||
| 
         OSSD output  | 
        
         Output  | 
        
         2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | 
    |||||
| 
         Max. l oad current  | 
        
         500 mA*2  | 
    ||||||
| 
         Residual vol tage (during ON)  | 
        
         Max. 2.5 V (with a cable length of 7 m 22.97')  | 
    ||||||
| 
         Leakage current  | 
        
         Max. 100 µA*3  | 
    ||||||
| 
         Max. capacitive load  | 
        
         2.2 µF (with a load resistance of 100 Ω)  | 
    ||||||
| 
         Load wiring resistance  | 
        
         Max. 2.5 Ω*4  | 
    ||||||
| 
         Non safety-rel ated output  | 
        
         AUX  | 
        
         Output with automatic PNP/NPN switching function, 50 mA max.  | 
    |||||
| 
         Interlock-reset-ready output  | 
    |||||||
| 
         Alarm output  | 
    |||||||
| 
         Clear/blocked output  | 
    |||||||
| 
         State information output 1, 2  | 
    |||||||
| 
         Muting lamp output  | 
        
         Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | 
    ||||||
| 
         Input  | 
        
         EDM input  | 
        
         Short-circuit current 10 mA  | 
    |||||
| 
         Wait input  | 
        
         Short-circuit current 2.5 mA  | 
    ||||||
| 
         Reset input  | 
    |||||||
| 
         Muting input 1, 2  | 
    |||||||
| 
         Override input  | 
    |||||||
| 
         Protection circuit  | 
        
         Reverse current protection, short-circuit protection for each output, surge protection for each output  | 
    ||||||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         IEC61496-1, EN61496-1, UL61496-1  | 
    ||||
| 
         EMI  | 
        
         EN55011 Class A, FCC Part15B Class A  | 
    ||||||
| 
         Safety  | 
        
         IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | 
    ||||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | 
    |||||
| 
         Current consumption (mA)  | 
        
         When the center indicator is ON  | 
        
         Transmitter  | 
        
         137*6  | 
        
         144*6  | 
        
         149*6  | 
        
         154*6  | 
    |
| 
         Receiver  | 
        
         96*6  | 
        
         98*6  | 
        
         101*6  | 
        
         104*6  | 
    |||
| 
         When the center indicator is OFF  | 
        
         Transmitter  | 
        
         126*6  | 
        
         132*6  | 
        
         136*6  | 
        
         140*6  | 
    ||
| 
         Receiver  | 
        
         78*6  | 
        
         80*6  | 
        
         81*6  | 
        
         83*6  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65/67 (IEC60529)  | 
    |||||
| 
         Overvoltage category  | 
        
         II  | 
    ||||||
| 
         Ambient light  | 
        
         Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | 
    ||||||
| 
         Operating ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    ||||||
| 
         Operating relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    ||||||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    ||||||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    ||||||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    ||||||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    ||||||
| 
         Material  | 
        
         Main unit case  | 
        
         Aluminum  | 
    |||||
| 
         Upper case/lower case  | 
        
         Zinc die-cast  | 
    ||||||
| 
         Front cover  | 
        
         Polycarbonate, SUS304  | 
    ||||||
| 
         Weight  | 
        
         Transmitter  | 
        
         2,850 g  | 
        
         3,140 g  | 
        
         3,440 g  | 
        
         3,730 g  | 
    ||
| 
         Receiver  | 
        
         2,880 g  | 
        
         3,170 g  | 
        
         3,470 g  | 
        
         3,760 g  | 
    |||
| 
         *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit.  | 
    |||||||
| 
         Model  | 
        
         SL-T11R  | 
    |||
| 
         Image  | 
        
         
  | 
    |||
| 
         Combined light curtain  | 
        
         SL-V Series  | 
    |||
| 
         Output  | 
        
         FSD1、2  | 
        
         230 VAC/4 A, 30 VDC/2 A (Resistance load)  | 
    ||
| 
         Life-span  | 
        
         Mechanical life: 10 million cycles or more/Electrical life: 0.1 million cycle or more*1  | 
    |||
| 
         Response time (ms)  | 
        
         ON→OFF  | 
        
         +6 ms  | 
    ||
| 
         OFF→ON  | 
        
         +15 ms  | 
    |||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMS  | 
        
         UL61496-1, IEC61496-1, EN61496-1  | 
    |
| 
         EMI  | 
        
         FCC Part15B Class A, ICES-003 Class A, EN55011 Class A  | 
    |||
| 
         Safety  | 
        
         UL61496-1, IEC61496-1, EN61496-1 (Type 4 ESPE), ISO 13849-1: 2015 (Cat 4 PLe), UL508, EN50178  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC ±10 %, Ripple (P-P) 10 % or less  | 
    ||
| 
         Current consumption  | 
        
         100 mA or less (at 24 VDC, SL-T11R alone)  | 
    |||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP20 (IEC60529), Set inside control panel with IP54 or more  | 
    ||
| 
         Pollution degree  | 
        
         2  | 
    |||
| 
         Overvoltage category  | 
        
         III  | 
    |||
| 
         Ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||
| 
         Relative humidity  | 
        
         15 to 85 % RH (No condensation)  | 
    |||
| 
         Storage temperature  | 
        
         -25 to +60 °C -13 to 140 °F (No freezing)  | 
    |||
| 
         Storage relative humidity  | 
        
         15 to 95 % RH  | 
    |||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||
| 
         Material  | 
        
         Polycarbonate  | 
    |||
| 
         Weight  | 
        
         Approx. 330 g  | 
    |||
| 
         *1 For the specifications for the outputs other than FSD and for each input, refer to the SL-V Instruction Manual.  | 
    ||||
| 
         Model  | 
        
         SL-U2  | 
    |||
| 
         Image  | 
        
         
  | 
    |||
| 
         System  | 
        
         Switching type  | 
    |||
| 
         Input power supply voltage  | 
        
         100 to 240 VAC ±10 % (50/60 Hz)  | 
    |||
| 
         Ripple/noise  | 
        
         240 mV p-p or less  | 
    |||
| 
         Output capacity  | 
        
         1.8 A  | 
    |||
| 
         Supply voltage interruption  | 
        
         10 ms max.  | 
    |||
| 
         Approved standards  | 
        
         EMC  | 
        
         EMI  | 
        
         EN61000-6-2, EN55011 Class A, FCC Part15 Class A  | 
    |
| 
         Safety  | 
        
         EN62368-1, EN62477-1, UL 60950-1, CSA 60950-1  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC ±10 %, Class 2  | 
    ||
| 
         Power consumption  | 
        
         135 VA  | 
    |||
| 
         Environmental resistance  | 
        
         Pollution degree  | 
        
         2  | 
    ||
| 
         Overvoltage category  | 
        
         II  | 
    |||
| 
         Insulation resistance  | 
        
         At least 50 MΩ (500 VDC mega, between all external terminals and case)  | 
    |||
| 
         Ambient temperature  | 
        
         -10 to +55 °C 14 to 131 °F (No freezing)  | 
    |||
| 
         Relative humidity  | 
        
         35 to 85 % RH (No condensation)  | 
    |||
| 
         Withstand voltage  | 
        
         1,500 VAC, 1 min. (between all external terminals and case)  | 
    |||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions  | 
    |||
| 
         Shock resistance  | 
        
         100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | 
    |||
| 
         Weight  | 
        
         Approx. 240 g  | 
    |||