Compact Laser Sensor
LR-X series
Separate Amplifier Model, Amplifier Units Expansion unit (Zero Line Type) LR-XN10
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | LR-XN10  | |||
Type  | —  | |||
Cable/Connector  | ||||
Main Unit/Expansion Unit  | Expansion Unit  | |||
No. of Control Outputs  | None*1  | |||
No. of External Inputs  | —  | |||
Response Time  | 500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable  | |||
IO-Link  | —  | |||
Functions  | Timer Function  | Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot  | ||
I/O  | Control Output  | —  | ||
External Input  | ||||
Unit Expansion  | Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.  | |||
Protection Circuit  | Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection  | |||
Number of Interference Prevention Devices  | OFF/4 units/8 units selectable*3  | |||
Power supply  | Power voltage  | 16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2  | ||
Power consumption  | During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V)  | |||
Environmental resistance  | Ambient temperature  | −20 to +55°C -4°F to 131°F (no freezing)*5  | ||
Relative humidity  | 35 to 85% RH (no condensation)  | |||
Vibration resistance  | 10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions  | |||
Shock resistance  | 500 m/s2 (50G); 3 times each for X, Y, and Z axes  | |||
Case Material  | Main Unit and Cover: Polycarbonate  | |||
Accessories  | Instruction manual  | |||
Weight  | Approx. 21 g  | |||
*1 This counts as 1 output when expanding with multiple units to the FS-MC8N/MC8P and NU Series.  | ||||