          Safety Interlock Switches

          GS series

          Select Language

          Locking Type

          Model

          GS-51P5

          GS-51N5

          GS-51P10

          GS-51N10

          GS-51PC

          GS-53PC

          GS-71P5

          GS-71N5

          GS-71P10

          GS-71N10

          GS-71PC

          GS-73PC

          Lock type

          Power-to-release type

          Power-to-lock type

          Type

          Standard type

          Advanced function type

          Standard type

          Advanced function type

          Response time

          Lock

          Lock→Unlock

          220 ms*1*2

          320 ms*1*2

          Unlock→Lock

          220 ms*1*2*3

          Lock

          Locking force (Fzh)

          Min. 2,000 N

          Alignment tolerance of lock

          ±2 mm ±0.08"

          Mechanical life-span

          1 million cycles or more (with door operation speed of 1 m/s)

          Acceptable operation frequency

          1 Hz*4

          Door radius

          Min. 250 mm 9.84"

          Auxiliary release

          Front, back

          Cascading

          Max. 25 units

          Control output (OSSD output)

          Output

          Transistor outputs × 2

          Max. load current

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          OFF state voltage

          Max 2.0 V (with a cable length of 5 m 16.40')

          Leakage current

          Max. 0.5 mA

          Max. capacitive load

          2.2 µF

          Load wiring resistance

          Max. 2.5 Ω

          AUX (Non-safety related output)

          Output

          Transistor output

          Number of outputs

          1

          2

          1

          2*7

          Max. load current

          50 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          External input (Short-circuit current)

          Safety input

          Approx.1.5 mA × 2

          Reset/EDM input

          -

          Approx. 10 mA × 1

          -

          Approx. 10 mA × 1

          Lock control input

          Approx. 2.5 mA × 1

          Approx. 2.5 mA × 2

          Approx. 2.5 mA × 1

          OSSD operation switching input

          -

          Approx. 2.5 mA × 2*8

          Applicable Standards (Safety)

          EN 61508, IEC 61508(SIL2/SIL3)
          EN 62061, IEC62061(SIL CL2/SIL CL3)
          EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
          EN ISO14119(Type4)
          IEC 60947-5-3, EN 60947-5-3
          UL 61010-1, CAN/CSA-C22.2 No.61010-1

          Protection circuit

          Reverse current protection, short-circuit protection and surge protection for each output

          Power supply

          Power voltage

          24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

          Power consumption

          3.4 W*5

          Environmental resistance

          Enclosure rating

          IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
          Enclosure Type 3/4X/12/13 (NEMA250)

          Operating ambient temperature

          -20°C to +55C° -4°F to 131°F (No freezing)

          Storage temperature

          -25°C to +70°C -13°F to 158°F (No freezing)*6

          Operating relative humidity

          5% to 95%RH

          Storage relative humidity

          Vibration resistance

          10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

          Shock resistance

          30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

          Material

          Sensor main unit

          Case

          SUS304, PPS, PBT, PAR, PA66, NBR

          Lock

          Aluminum alloy, Zinc die cast (Nickel chrome plating)

          Cable

          PVC

          Actuator

          Case

          PPS, PBT, NBR

          Lock

          Aluminum alloy, SUS303

          Weight

          Approx. 560 g

          Approx. 770 g

          Approx. 380 g

          Approx. 560 g

          Approx. 770 g

          Approx. 380 g

          *1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
          *2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
          *3 430 ms when locked at the same time the actuator is detected.
          *4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
          *5 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
          *6 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.
          *7 The number of AUX outputs is 1 when the OSSD operation is open/close link mode.
          *8 The number of OSSD operation switching inputs is 1 when the OSSD operation is lock link mode.

          Non-Contact Type

          Model

          GS-10PC

          GS-11P5

          GS-11N5

          GS-11P10

          GS-11N10

          GS-11PC

          GS-13P5

          GS-13PC

          Type

          Simple function type

          Standard type

          Advanced function type

          Operating distance

          Front

          Sao(OFF→ON)

          10 mm 0.39"

          Sar(ON→OFF)

          18 mm 0.71"

          Side

          Sao(OFF→ON)

          6 mm 0.24"

          Sar(ON→OFF)

          14 mm 0.55"

          Response time

          Detection

          Detect→Not detect

          20 ms + 2 ms × (number of units cascaded -1)*1

          Not detect→Detect

          30 ms + 25 ms × (number of units cascaded -1)*1

          Door operation

          Acceptable operation frequency

          3 Hz

          Cascading

          Standard

          -

          Max. 30 units

          Using Y-shaped connector

          -

          Max. 4 units*3

          -

          Control output (OSSD output)

          Output

          Transistor outputs × 2

          Max. load current

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Max. 100 mA

          Max. 150 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          OFF state voltage

          Max 2.0 V (with a cable length of 5 m 16.40')

          Leakage current

          Max. 500 µA

          Max. capacitive load

          2.2 µF

          Load wiring resistance

          Max.2.5Ω

          AUX (Non-safety related output)

          Output

          Transistor output

          Number of outputs

          1

          Max. load current

          50 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          External input (Short-circuit current)

          Safety input

          -

          Approx. 1.5 mA × 2

          Reset/EDM input

          -

          Approx. 5.0 mA × 1

          Applicable Standards (Safety)

          EN 61508, IEC 61508 (SIL3)
          EN 6206, IEC62061 (SIL CL3)
          EN ISO13849-1: 2015 (PLe, Category 4)
          EN ISO14119 (Type4)
          IEC 60947-5-3, EN 60947-5-3
          UL 61010-1, CAN/CSA-C22.2 No.61010-1

          Protection circuit

          Reverse current protection, short-circuit protection and surge protection for each output

          Power supply

          Power voltage

          24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

          Power consumption

          0.8 W

          Environmental resistance

          Enclosure rating

          IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

          Operating ambient temperature

          -20°C to +55°C -4°F to 131°F (No freezing)

          Storage temperature

          -25°C to +70°C -13°F to 158°F (No freezing)*2

          Operating relative humidity

          5% to 95%RH

          Storage relative humidity

          Vibration resistance

          10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

          Shock resistance

          30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

          Material

          Sensor main unit

          Case

          Zinc die cast (Nickel chrome plating), PBT, PAR

          Cable

          PVC

          Actuator

          Case

          SUS430, SUS304, PBT

          Weight

          Approx. 80 g

          Approx. 270 g

          Approx. 480 g

          Approx. 80 g

          Approx. 280 g

          Approx. 80 g

          *1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
          *2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.
          *3 When AUX outputs of each unit are not used, it is possible to cascade up to 10 units.