High-speed, High-Accuracy Digital Displacement Inductive Sensor
EX-V series
Amplifier Unit PNP EX-V05P
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | EX-V05P*1  | |||
Type  | Amplifier Unit PNP  | |||
Shape  | ø14.5 x 20 mm ø0.57" x 0.79" Cylindrical, threaded  | |||
Measuring range  | 0 to 5 mm 0.20"  | |||
Display range  | -19,999 to +19,999  | |||
Linearity  | ±0.3% of F.S.  | |||
Resolution (No. of averaging  | 1 µm  | |||
Sampling rate  | 40,000 samplings max./sec. *2  | |||
Display speed  | 20 times/sec.  | |||
Display power  | 7-segment 2-color LED  | |||
Over-range alarm  | ±FFFF is displayed.  | |||
Control input  | PNP: Applied voltage; 10 to 30 V  | |||
Control output  | Setting method  | Upper/lower 2-level setting x 4 patterns (selectable)  | ||
Signal  | PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)  | |||
Response time  | 0.075 ms (at maximum speed)  | |||
OFF-delay time  | 60 ms  | |||
Strobe output  | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)  | |||
Alarm output  | PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)  | |||
Analog output voltage  | Output voltage  | ±5V  | ||
Impedance  | 100 Ω  | |||
Response time  | 0.075 ms (at maximum speed)  | |||
Temperature characteristics  | 0.07% of F.S./°C *3  | |||
Major functions  | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.  | |||
Rating  | Power voltage  | 24 VDC ±10%, Ripple (P-P): 10% max.  | ||
Current consumption  | 240 mA max.  | |||
Environmental resistance  | Ambient temperature  | 0 to 50°C 32 to 122 °F  | ||
Relative humidity  | 35 to 85%, No condensation  | |||
Vibration resistance  | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions  | |||
Weight  | Approx. 235 g  | |||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials.  | ||||