Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          1. Home
          2. Products
          3. Measurement Sensors
          4. Laser Displacement Sensors
          5. Image-Based Laser Sensor
          6. Specs

          Image-Based Laser Sensor

          IX series

          Select Language

          Sensor Head

          Model

          IX-055

          IX-080

          IX-150

          IX-360

          IX-360W

          Reference distance

          55 mm 2.17"

          80 mm 3.15"

          150 mm 5.91"

          360 mm 14.17"

          Measuring distance

          45 to 65 mm 1.77" to 2.56"

          62 to 98 mm 2.44" to 3.86"

          100 to 200 mm 3.94" to 7.87"

          280 to 440 mm 11.02" to 17.32"

          Detection area

          Scan mode

          Measuring distance of 45 mm 1.77": 27.5 × 20.5 mm 1.08" × 0.81"
          Measuring distance of 55 mm 2.17": 32.5 × 24.5 mm 1.28" × 0.96"
          Measuring distance of 65 mm 2.56": 37.5 × 28.5 mm 1.48" × 1.12"
          (X direction) × (Y direction) *1

          Measuring distance of 62 mm 2.44": 36.5 × 27.0 mm 1.44" × 1.06"
          Measuring distance of 80 mm 3.15": 45.5 × 34.0 mm 1.79" × 1.34"
          Measuring distance of 98 mm 3.86": 54.5 × 41.0 mm 2.15" × 1.61"
          (X direction) × (Y direction) *1

          Measuring distance of 100 mm 3.94": 56.5 × 42.0 mm 2.22" × 1.65"
          Measuring distance of 150 mm 5.91": 82.5 × 61.5 mm 3.25" × 2.42"
          Measuring distance of 200 mm 7.87": 108.5 × 81.0 mm 4.27" × 3.19"
          (X direction) × (Y direction) *1

          Measuring distance of 280 mm 11.02": 66.0 × 49.5 mm 2.6" × 1.95"
          Measuring distance of 360 mm 14.17": 84.0 × 63.0 mm 3.31" × 2.48"
          Measuring distance of 440 mm 17.32": 102.0 × 76.5 mm 4.02" × 3.01"
          (X direction) × (Y direction) *1

          Measuring distance of 280 mm 11.02": 150 × 113 mm 5.91" × 4.45"
          Measuring distance of 360 mm 14.17": 192 × 144 mm 7.56" × 5.67"
          Measuring distance of 440 mm 17.32": 234 × 176 mm 9.21" × 6.93"
          (X direction) × (Y direction) *1

          Line mode

          Measuring distance of 45 mm 1.77": 27.5 mm 1.08"
          Measuring distance of 55 mm 2.17": 32.5 mm 1.28"
          Measuring distance of 65 mm 2.56": 37.5 mm 1.48"
          (X direction) *1

          Measuring distance of 62 mm 2.44": 36.5 mm 1.44"
          Measuring distance of 80 mm 3.15": 45.5 mm 1.79"
          Measuring distance of 98 mm 3.86": 54.5 mm 2.15"
          (X direction) *1

          Measuring distance of 100 mm 3.94": 56.5 mm 2.22"
          Measuring distance of 150 mm 5.91": 82.5 mm 3.25"
          Measuring distance of 200 mm 7.87": 108.5 mm 4.27"
          (X direction) *1

          Measuring distance of 280 mm 11.02": 66.0 mm 2.6"
          Measuring distance of 360 mm 14.17": 84.0 mm 3.31"
          Measuring distance of 440 mm 17.32": 102.0 mm 4.02"
          (X direction) *1

          Measuring distance of 280 mm 11.02": 150 mm 5.91"
          Measuring distance of 360 mm 14.17": 192 mm 7.56"
          Measuring distance of 440 mm 17.32": 234 mm 9.21"
          (X direction) *1

          Laser Light source

          Light source

          660 nm (visible light) wavelength red semiconductor laser

          Laser class

          Class II laser product (FDA [CDRH] Part 1040.10), Class 2 laser product (IEC 60825-1: 2014)

          Class 2 laser product (IEC 60825-1: 2014, FDA [CDRH] Part 1040.10 *11)

          Output

          0.95 mW (FDA [CDRH] Part 1040.10), 1.6 mW (IEC 60825-1: 2014)

          2.8 mW

          Height(Z direction)

          Minimum detectable object size

          Scan mode

          Height

          ø0.7 mm ø0.0276" *2

          ø1.0 mm ø0.0394" *2

          ø1.7 mm ø0.0669" *2

          ø1.8 mm ø0.0709" *2

          ø3.8 mm ø0.1496" *2

          Average height

          ø0.4 mm ø0.0157" *3

          ø0.5 mm ø0.0197" *3

          ø0.9 mm ø0.0354" *3

          ø1.2 mm ø0.0472" *3

          ø2.6 mm ø0.1024" *3

          Pin height

          ø0.3 mm ø0.0118" *4

          ø0.4 mm ø0.0157" *4

          ø0.8 mm ø0.0315" *4

          ø0.9 mm ø0.0354" *4

          ø1.9 mm ø0.0748" *4

          Line mode

          0.5 mm × 0.5 mm 0.0197" × 0.0197" *5

          0.7 mm × 0.7 mm 0.0276" × 0.0276" *5

          1.1 mm × 1.1 mm 0.0433" × 0.0433" *5

          1.2 mm × 1.5 mm 0.0472" × 0.0591" *5

          2.6 mm × 2.6 mm 0.1024" × 0.1024" *5

          Repeatability

          10 μm *6

          20 μm *6

          50 μm *6

          150 μm *6

          Width(X direction)

          Minimum edge detection

          Line mode

          0.3 mm 0.0118" *7

          0.4 mm 0.0157" *7

          0.5 mm 0.0197" *7

          1 mm 0.0394" *7

          2 mm 0.0787" *7

          Estimated detection

          (When measuring the height between two points, the minimum step difference is as follows.
          IX-055: 100 μm / IX-080: 200 μm / IX-150: 500 μm / IX-360: 1000 μm / IX-360W: 1000 μm) *6

          Sampling cycle

          Scan mode

          120 ms (min.) (typical)

          Line mode

          6 ms / 11 ms (selectable)

          Image receiving element

          Monochrome CMOS image sensor

          Image capture lighting

          Light source

          Red LED

          Lighting method

          Pulse lighting

          Temperature characteristics

          0.04% of F.S./°C *8

          0.08% of F.S./°C *8

          0.04% of F.S./°C *8

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp, 5000 lux or less *9

          Incandescent lamp, 3000 lux or less *9

          Ambient temperature

          0 to +45°C 32 to 113°F (No freezing) *10

          Relative humidity

          35 to 85% RH (No condensation)

          Vibration resistance

          10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2 1640'/s2, 3 times in each of the 3 directions

          Material

          Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector: Zinc die-casting

          Weight

          Approx. 190 g

          Approx. 300 g

          *1 X: Long-side direction of laser, Y: Short-side direction of laser
          *2 With a correct reference distance. When measuring using the height tool, measurement point min., and no position adjustment in scan mode.
          *3 With a correct reference distance. When measuring using the average height tool, average size min., and no position adjustment in scan mode.
          *4 With a correct reference distance. When measuring using the pin height tool and no position adjustment in scan mode.
          *5 With a correct reference distance. When measuring using the height tool, tool window size min., and no position adjustment in line mode.
          *6 When measuring a KEYENCE reference target (white diffuser) in the center of the field of view at the reference distance in scan mode using the “Max.” measurement point of a height tool.
          *7 With a correct reference distance.
          When measuring metal gauge blocks in line mode using a 4-count averaging filter and the edge positioning tool with no position adjustment.
          In width mode with the width/diameter tool, the minimum detection value is twice the minimum edge detection.
          The minimum height differences (estimated) required for edge detection of each model at the reference distance are as follows.
          IX-055: 0.8 mm 0.03", IX-080: 1.0 mm 0.04", IX-150: 2 mm 0.08", IX-360: 4 mm 0.16", IX-360W: 4 mm 0.16"
          *8 At the reference distance from the target.
          The F.S. for each model are as follows.
          IX-055: ±10 mm ±0.39", IX-080: ±18 mm ±0.71", IX-150: ±50 mm ±1.97", IX-360: ±80 mm ±3.15", IX-360W: ±80 mm ±3.15"
          *9 Using the default settings with a laser light source as the target.
          *10 With metal mounting.
          *11 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No. 56.

          Sensor Amplifier

          Model

          IX-H2000

          IX-H2050

          Main unit / expansion unit

          Main unit

          Expansion unit

          Display

          Min. display unit

          Z axis

          10 μm *1

          X axis

          50 μm *1

          Display range

          Z axis

          ±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1

          X axis

          ±999.95 to ±999 mm 39.33" (with 4 selectable steps) *1

          Tools

          Scan mode

          Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation,
          Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool*2

          Line mode

          Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation,
          Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools *3, Position adjustment: 1 tool, Tilt adjustment: 1 tool*2

          Other functions

          Common

          Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR),
          Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching,
          Simultaneous main unit/expansion unit input, Mutual interference prevention, Security

          Scan mode

          Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain),
          Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram,
          Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function

          Line mode

          Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement,
          HOLD function, Alarm setting, Measurement method (Ave./Max./Min.), Laser sensitivity adjustment, Averaging filter, Median filter, X-axis median filter

          Input

          Input

          Switchable between non-voltage input and voltage input
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Number of inputs

          8 (IN1 to IN8)

          Function

          IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions
          Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error)

          Output

          Output

          Open collector output; NPN/PNP switchable, N.O./N.C. switchable
          For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less
          For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less

          Number of inputs

          10 (OUT1 to OUT10)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgment result (All OK/Any OK/NG), Run, Busy, Error, Position adjustment result, Tilt adjustment result, Result of the logical operation of each tool,
          Monochrome area / Height area tool result (OK/NG), Height / Step / Max./Min. / Calculation tool result (OK/NG/HIGH/LO), Alarm

          Analog voltage output

          ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω *4

          Not available

          Analog current output

          4 to 20 mA, Max. load resistance: 350 Ω *4

          Number of programs

          32

          Statistical information

          Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
          Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1 *5

          Detection history

          Saved history

          Scan mode

          50 (FTP client function: Enabled/High-resolution mode: Enabled)
          80 (FTP client function: Enabled/High-resolution mode: Disabled)
          70 (FTP client function: Disabled/High-resolution mode: Enabled)
          100 (FTP client function: Disabled/High-resolution mode: Disabled)
          *6

          Line mode

          400 (FTP client function: Enabled/High-resolution mode: -)
          500 (FTP client function: Disabled/High-resolution mode: -)
          *6

          Save conditions

          Selectable between NG only and All *6

          Image data transmission (FTP client function)

          Destination

          FTP server

          Method

          Selectable between bmp, jpeg, and txt

          Conditions

          4 conditions
          Selectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG)

          Ethernet

          Standard

          100BASE-TX/10BASE-T *7

          Not available *7

          Connector

          RJ45 8-pin connector *7

          Interface compatibility

          CC-Link, DeviceNetTM, EtherNet/IPTM, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *8

          Number of connectible units

          Main units: 1, Expansion units: 1, Communication units (DL): 1

          Ratings

          Power voltage

          24 VDC ±10% (including ripple)

          Supplied from main unit

          Current consumption

          Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *9

          Environmental resistance

          Ambient temperature

          0 to +50°C 32 to 122°F (No freezing)

          Relative humidity

          35 to 85% RH (No condensation)

          Material

          Main unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA /
          Head connector: Zinc + Ni plating, PA / Ethernet connector: Copper alloy + Ni plating / Rear heat sink:
          Aluminum / Main unit rear DIN rail fixing tab: POM / Nameplate: PC

          Weight

          Approx. 210 g

          Approx. 190 g

          *1 For displaying on an IX Series control panel or PC software.
          *2 Configurable for each program.
          *3 Up to 8 tools can be used for the diameter tool only.
          *4 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
          *5 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
          *6 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.
          *7 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
          *8 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
          *9 Includes a DL Series communication unit.

          Sensor Amplifier

          Model

          IX-1000

          IX-1050

          Main unit / expansion unit

          Main unit

          Expansion unit

          Display

          Min. display unit

          10 µm*1

          Display range

          ±999.99 to ±999 mm (with 4 selectable steps)*1

          Tools

          Scan mode

          Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2

          Line mode

          Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction
          (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2

          Other functions

          Common

          ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,
          Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,
          Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security

          Scan mode

          Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination,
          Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,
          Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range

          Line mode

          Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)

          Input

          Input

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Number of inputs

          8 (IN1 to IN8)

          Function

          IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions
          Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)

          Output

          Output

          Open collector output; NPN/PNP switchable, N.O./N.C. switchable
          For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less
          For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less

          Number of inputs

          10 (OUT1 to OUT10)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,
          Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm

          Analog voltage output

          ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω*3

          Not available

          Analog current output

          4 to 20 mA, max. load resistance: 350 Ω*3

          Number of programs

          32

          Statistical information

          Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
          Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*4

          Detection history

          Saved history

          100*5

          Save conditions

          Selectable from NG only / All*5

          Ethernet

          Standard

          100BASE-TX/10BASE-T*6

          Not available

          Connector

          RJ45 8-pin connector*6

          Interface compatibility

          CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7

          Number of connectible units

          Main units: 1, Expansion units: 1, Communication units (DL) : 1

          Ratings

          Power voltage

          24 VDC ±10 % (including ripple)

          Supplied from main unit

          Current consumption

          Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*8

          Environmental resistance

          Ambient temperature

          0 to +50°C 32 to 122°F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/
          Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/
          Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC

          Weight

          Approx. 210 g

          Approx. 190 g

          *1 For displaying on an IX Series control panel or PC software.
          *2 Configurable for each program.
          *3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
          *4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set.
          *5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software.
          *6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit.
          *7 When a DL Series device is used. Contact KEYENCE for information on other interfaces.
          *8 Includes a DL Series communication unit.

          IX Series Control Panel

          Model

          IX-CP50

          Display panel

          5.7" TFT color LCD, 640 × 480 (VGA)

          Backlight

          Method

          White LED

          Duration

          Approx. 50,000 hours (25 °C 77 °F)

          Touch panel

          Method

          Analog resistive

          Actuating force

          0.8 N or less

          Ethernet

          Standard

          100BASE-TX/10BASE-T*1

          Connector

          M12 4-pin connector*1

          Languages

          Japanese/English/German/Simplified Chinese

          Expanded memory

          USB memory*2

          Ratings

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.3 A or less

          Environmental resistance

          Enclosure rating

          IP40

          Ambient temperature

          0 to +50°C 32 to 122°F (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)*3

          Drop resistance

          1.3 m 4.3' onto concrete (2 times in an arbitrary direction)

          Vibration resistance

          10 to 55 Hz; double amplitude 0.7 mm; 2 hours in each of the X, Y, and Z directions

          Material

          Main unit case: PC/Power connector: Brass + Ni plating/
          Ethernet cable connector: Zinc + Ni plating, PA/USB connector cover: EDPM/
          Pen holder: PC/Adapter fixing hook: POM/LED lamp cover: PC/
          Mounting adapter: PC/Stylus: POM

          Weight

          Main unit: Approx. 450 g
          With wall mounting adapter and stylus attached: Approx. 485 g

          *1 Dedicated for use in connecting to the IX-1000/1050.
          *2 Use only products recommended by KEYENCE.
          *3 If the ambient operating temperature exceeds 40°C 104°F, use the product under conditions where the absolute humidity is 85% RH or less at 40°C 104°F.

          PC Software

          Model

          IX-H1

          System requirements

          Interface

          Equip the Ethernet (100BASE-TX) interface

          OS

          Either Windows 7 Home Premium/Professional/Ultimate or
          Windows 10 Home/Pro/Enterprise must be pre-installed*1

          Languages

          Japanese/English/German/Simplified Chinese

          Processor

          Compliant with OS system requirements

          Memory capacity

          Required capacity for installation

          1 GB or more

          Monitor

          Resolution: 1024 × 768 pixels or higher,
          Display color: High Color (16 bits) or higher

          Operating conditions

          .NET Framework 4.5.2 or later installed.*2

          *1 32-bit and 64-bit versions supported.
          *2 If .NET Framework 4.5.2 or later is not installed, .NET Framework 4.5.2 will be automatically installed during IX-H1 installation.

          Tips of Measurement

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE CORPORATION OF AMERICA 500 Park Boulevard, Suite 200, Itasca,
          IL 60143, U.S.A.
          Phone: 1-888-KEYENCE [1-888-539-3623]
          E-mail: tech@keyence.com
          Career Opportunities: KEYENCE Career Site

          Measurement Sensors