          GS-13P5

          Non-contact type High performance type PNP Standard cable 5 m

          SPECIFICATIONS

          Select Language

          Model

          GS-13P5

          Type

          Advanced function type

          Output

          PNP

          Operating distance

          Front

          Sao(OFF→ON)

          10 mm 0.39"

          Sar(ON→OFF)

          18 mm 0.71"

          Side

          Sao(OFF→ON)

          6 mm 0.24"

          Sar(ON→OFF)

          14 mm 0.55"

          Response time

          Detection

          Detect→Not detect

          20 ms + 2 ms × (number of units cascaded -1)*1

          Not detect→Detect

          30 ms + 25 ms × (number of units cascaded -1)*1

          Door operation

          Acceptable operation frequency

          3 Hz

          Cascading

          Standard

          Max. 30 units

          Using Y-shaped connector

          -

          Control output (OSSD output)

          Output

          Transistor outputs × 2

          Max. load current

          Max. 150 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          OFF state voltage

          Max 2.0 V (with a cable length of 5 m 16.40')

          Leakage current

          Max. 500 µA

          Max. capacitive load

          2.2 µF

          Load wiring resistance

          Max.2.5Ω

          AUX (Non-safety related output)

          Output

          Transistor output

          Number of outputs

          1

          Max. load current

          50 mA

          Residual voltage (during ON)

          Max 2.5 V (with a cable length of 5 m 16.40')

          External input (Short-circuit current)

          Safety input

          Approx. 1.5 mA × 2

          Reset/EDM input

          Approx. 5.0 mA × 1

          Protection circuit

          Reverse current protection, short-circuit protection and surge protection for each output

          Power supply

          Power voltage

          24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

          Power consumption

          0.8 W

          Environmental resistance

          Enclosure rating

          IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

          Operating ambient temperature

          -20°C to +55°C -4°F to 131°F (No freezing)

          Storage temperature

          -25°C to +70°C -13°F to 158°F (No freezing)*2

          Operating relative humidity

          5% to 95%RH

          Storage relative humidity

          Vibration resistance

          10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

          Shock resistance

          30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

          Applicable Standards (Safety)

          EN 61508, IEC 61508 (SIL3)
          EN 6206, IEC62061 (SIL CL3)
          EN ISO13849-1: 2015 (PLe, Category 4)
          EN ISO14119 (Type4)
          IEC 60947-5-3, EN 60947-5-3
          UL 61010-1, CAN/CSA-C22.2 No.61010-1

          Material

          Sensor main unit

          Case

          Zinc die cast (Nickel chrome plating), PBT, PAR

          Cable

          PVC

          Actuator

          Case

          SUS430, SUS304, PBT

          Weight

          Approx. 280 g

          *1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
          *2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Safety