Measure Solder/Bump Height and Volume: 100% Quantification With Tilt Correction Using Light-Section 3D Profiles
The light-section LJ-X8000 Series performs 100% quantification of the height and volume of solder balls, BGA/CSP bumps, and fillets using 3D profiles. It stably measures even same-color and specular solder using the true height with tilt correction.
Three Challenges That Arise When Solder/Bump Height and Volume Cannot Be Quantified
For solder balls, bumps, and paste, the “true height” and volume cannot be quantified using only the area or 2D images, weakening the basis for process adjustments.
True Height and Volume Cannot Be Determined From Area/2D Images
If the state of solder balls or BGA/CSP bumps is captured using only the area or 2D images, three-dimensional quantities such as the height and volume of the buildup cannot be quantified. If there is a slight tilt in the target, the apparent dimensions will shift, deviating from the actual height. If height and volume remain unquantified, subtle changes in print volume or mounting height cannot be fed back to the process, delaying the start of mass production.
Solder of the Same Color, With Low Steps, or With a Specular Surface Cannot Be Measured Stably
Solder and paste are the same color as their surroundings, have small steps, and often have specular or glossy surfaces, making them difficult targets to stably capture contours and heights using methods that rely on changes in light and dark. If noise is introduced due to multiple reflections or diffuse reflections, measurement values will vary, making it impossible to record the true height as a numerical value. If stable measurement is not possible, threshold adjustments become dependent on individual judgment, undermining the very standards of process control.
Data for All Parts Cannot Be Accumulated, Making It Impossible to Manage Process Variation
Sampling or offline measurement cannot capture the entire variation in solder/bump height, meaning the data required for statistical process control (SPC) is not available. If trend changes cannot be captured early, deviations in printing, mounting, and reflow conditions will escape to subsequent processes. Quantifying and accumulating height and volume for 100% of parts is the only way to provide a basis for trend management and condition setting.
Measurement Points for Quantifying Height and Volume in the Mounting Process
In each process of printing, mounting, and reflow, the height and volume of solder, bumps, and paste are quantified and used for condition setting and data accumulation.
- 1 After solder paste printing – Process ①. The thickness, volume, and application position of solder paste printed with a metal mask are measured. Used for optimizing printing conditions and accumulating 100% of data.
- 2 After component mounting – Process ②. The height and position of mounted components are measured using height data. Mounting variation is quantified and fed back to the next process.
- 3 After reflow (solder joint) – Process ③. Quantifies the height and volume of solder balls, fillets, and bumps using 3D profiles. Measures multiple locations simultaneously using the true height with tilt correction.
Comparison of Methods for Measuring Solder/Bump Height and Volume
Depending on the measurement method, there are significant differences in true height quantification, tilt correction, and compatibility with same-color and specular solder.
| Comparison items | LJ-X8000 Series (Light-section 3D) |
Pattern projection method (fringe projection 3D) | 2D image method | Contact method (stylus method) |
|---|---|---|---|---|
Height/volume quantification (true height) |
LJ-X8000 Series (Light-section 3D)
◎ Direct quantification using cross-sectional profiles
|
Pattern projection method (fringe projection 3D)
△ Acquired across a surface (varies by target)
|
2D image method
× Height is difficult to obtain
|
Contact method (stylus method)
△ Height at a point only
|
Tilt/misalignment correction |
LJ-X8000 Series (Light-section 3D)
◎ Supported by 3D position correction function
|
Pattern projection method (fringe projection 3D)
△ Correction depends on the configuration
|
2D image method
× Apparent dimensions deviate
|
Contact method (stylus method)
× Setup is required
|
Support for same-color/low-profile solder |
LJ-X8000 Series (Light-section 3D)
○ Stable with height information
|
Pattern projection method (fringe projection 3D)
△ Varies depending on the target
|
2D image method
× Contrast is difficult to obtain
|
Contact method (stylus method)
△ Not suitable for fine shapes
|
Support for specular/glossy solder |
LJ-X8000 Series (Light-section 3D)
○ Supported by stray light suppression function
|
Pattern projection method (fringe projection 3D)
△ Easily affected by reflection
|
2D image method
× Unstable due to glare
|
Contact method (stylus method)
△ Risk of deformation/scratches
|
Inline (without stopping the target) |
LJ-X8000 Series (Light-section 3D)
○ 100% measurement during transfer
|
Pattern projection method (fringe projection 3D)
△ Depends on stopping and cycle time
|
2D image method
△ Depends on the model
|
Contact method (stylus method)
× Requires stopping and contact
|
Cross-sectional profile acquisition |
LJ-X8000 Series (Light-section 3D)
◎ Acquires high-definition cross-sections
|
Pattern projection method (fringe projection 3D)
△ Mainly surface height maps
|
2D image method
× Not available
|
Contact method (stylus method)
△ Acquired by tracing
|
100% data storage and SPC |
LJ-X8000 Series (Light-section 3D)
◎ Stores numerical values for all parts
|
Pattern projection method (fringe projection 3D)
△ Depends on the configuration
|
2D image method
△ Mainly features other than height
|
Contact method (stylus method)
× Sample inspection is standard
|
Role (Strengths) |
LJ-X8000 Series (Light-section 3D)
Solder/bump height and volume quantification
|
Pattern projection method (fringe projection 3D)
Surface height map
|
2D image method
Flat surface appearance
|
Contact method (stylus method)
Point height of stationary target
|
Why Choose the LJ-X8000 Series
The LJ-X8000 Series uses a blue laser light-section method to capture the "true height" of cross sections, and outputs the height and volume with tilt corrected by the 3D position correction function. It handles same-color, low-profile, and specular solder effectively, achieving inline quantitative measurement that is difficult with pattern projection or 2D image methods.
LJ-X8000 Series Supporting Solder/Bump Height and Volume Measurement
It obtains cross-sectional profiles using a blue laser light-section method to quantify the height and volume of solder, bumps, and paste.
Supports 100% Quantification of Solder/Bump Height and Volume — LJ-X8000 Series
2D/3D Laser Profiler
This inline profile measurement system obtains cross-sectional profiles of the target surface using a blue laser light-section method to quantify height, volume, and steps. With the 3D position correction function, even if there is misalignment or tilt during transfer, measurement can be performed using the corrected "true height," allowing 100% quantitative measurement of the height and volume of solder balls, BGA/CSP bumps, and fillets. With high-definition 3D profiles and stray light suppression, it stably captures solder that is the same color as the surroundings with small height differences, as well as specular or glossy solder. A lineup of 10 sensor heads is available depending on the accuracy and measurement area, and a dual-head configuration allows measurement of solder in positions that cannot be seen with a single unit. We also offer the WI-5000 Series 3D interference measurement sensor, which can measure the entire surface at once.
Get Detailed Materials on the LJ-X8000 Series
You can download a free catalog summarizing specifications for compatible heads, system configuration, and measurement examples.
Application Examples of Solder/Bump Height and Volume Measurement
Used for quantifying height and volume in mounting processes, such as solder joints, solder paste, and bumps.
Solder Height Measurement on Lead Frames
Measures solder height on lead frames before mounting chips. With an ultra-high-sensitivity CMOS featuring our proprietary single-shot HDR function, stable measurement is achieved even for targets with mixed surface conditions.
Solder Paste Volume Measurement
Measures the volume of printed/applied solder paste using 3D data. Maximum/minimum height and volume can be calculated, which can be used for determining conditions and accumulating 100% of the data.
Wafer Bump Height Measurement (WI-5000 Series)
Instantly measures bump height on wafers, which takes time with measuring microscopes, leading to a reduction in man-hours and variation among operators.
Frequently Asked Questions About Solder/Bump Height and Volume Measurement (LJ-X8000 Series)
Q How can the height and volume of solder and bumps be measured?
A
The LJ-X8000 Series obtains cross-sectional profiles using a blue laser light-section method to quantify the height and volume of solder balls and bumps. It measures multiple locations simultaneously in a single scan, allowing data to be accumulated for 100% of the targets.
Q Can BGA/CSP bump height and coplanarity also be measured?
A
Yes, they can be measured. The height of BGA/CSP bumps and solder balls can be quantified using 3D profiles, and coplanarity can also be calculated from that data. Since the flatness of terminal pins is a different target, we will guide you to the dedicated measurement page.
Q Can glossy or same-color solder be measured stably?
A
Yes, they can be measured. Because 3D images are generated using height information, they are less affected by patterns and colors. Additionally, the stray light suppression function is highly resistant to multiple reflections and diffuse reflections, allowing stable measurement of specular, glossy, or same-color solder with small height differences.
Q How does it differ from the pattern projection method?
A
The LJ-X8000 Series directly captures the “true height” of the cross section using the light-section method, and corrects tilt using 3D position correction. The difference is that it is highly resistant to same-color, low-profile, and specular solder, and can output height and volume while suppressing the effects of tilt and misalignment.
Q Can measurements be made inline without stopping the target?
A
Yes, they can be measured. Even if there is misalignment or tilt during transfer, the 3D position correction function corrects for it, allowing 100% inline measurement of height and volume without stopping the target.