Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Notice of Continued Operations (information related to COVID-19)
          Click for the latest on how KEYENCE is continuing to support our customers
          1. Home
          2. Products
          3. Safety
          4. Safety Controller
          5. Safety Controller
          6. Specs

          Safety Controller

          SC series

          Select Language

          Model

          SC-S11

          Response time

          25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON)

          Safety output (S-OUTPUT)

          Output

          Two PNP outputs

          Max. load current

          500 mA

          Residual voltage (when ON)

          2.5 V maximum (with a load current of 500 mA)

          Leakage current

          1.2 mA maximum

          Max. capacitive load

          2.2 µF (with a load resistance of 100 Ω)

          Load wiring length

          30 m maximum

          Safety input (S-INPUT, enable input)

          Input type

          Contact output device connection or PNP output device connection

          Short-circuit current

          Approx 5mA

          ON/OFF voltage

          Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less

          Wiring length

          30 m maximum

          Safety related input

          Input type

          Non-voltage contact input (EDM input, reset input)

          Short-circuit current

          EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input)

          Wiring length

          30 m max. (EDM input, reset input)

          Non-safety output

          Output

          PNP/NPN totem pole output (auxiliary output, lockout output)

          Max. load current

          50mA (auxiliary output, lockout output)

          Load wiring length

          10 m maximum (auxiliary output, lockout output)

          Non-safety input

          Input type

          No-voltage contact input or PNP or NPN open-collector input (external off input)

          Short-circuit current

          Approx 5mA (external off input)

          ON/OFF voltage

          Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input)

          Wiring length

          10 m maximum (external off input)

          Protection circuit

          Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection

          Approved standards

          EMC

          EMS

          IEC 61496-1, EN61496-1, UL61496-1

          EMI

          EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A

          Safety

          ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1

          Rating

          Power voltage

          24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          1.3 A (at maximum load)

          Environmental resistance

          Enclosure rating

          IP20 (IEC60529)
          Must be installed within a control panel rated at IP54 or higher.

          Pollution degree

          2 (IEC60664/EN50178)

          Overvoltage category

          2 (IEC60664, EN50178)

          Insulation resistance

          100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case

          Operating ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Storage temperature

          -20 to +65 °C -4 to 149 °F (No freezing)

          Operating relative humidity

          35 to 85 % RH (No condensation)

          Storage relative humidity

          35 to 85 % RH

          Withstand voltage

          1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Material

          Main unit case

          Polycarbonate (UL94-V2)

          Weight

          160 g or less

          *1 The following mark is displayed on the ratings indication label on the side of the main unit to identify it as a UL508-certified product.

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE CORPORATION OF AMERICA 500 Park Boulevard, Suite 200, Itasca,
          IL 60143, U.S.A.
          Phone: 1-888-KEYENCE [1-888-539-3623]
          Callers from some carriers are experiencing difficulty reaching us. If you receive a busy tone, please try again or email us at the address below. E-mail: tech@keyence.com
          Career Opportunities: KEYENCE Career Site

          Safety