Digital Fiber Optic SensorsFS-N40 series

Expansion Unit (Zero Line Type)

FS-N40

SPECIFICATIONS

Select Language

Model

FS-N40

Type

Zero Line Type

Main unit/expansion unit

Expansion unit

Number of control outputs

None*1

Light source LED

Transmitter side: Red, four-element LED (wavelength: 660 nm)

Response time

23 µs (S-HSPD*2) /50 µs (HSPD*3) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)

External input

Input time: 2 ms (ON) /20 ms (OFF) or longer*4

Unit expansion

Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

Mutual interference prevention

S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)

Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5

Power consumption

During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)
ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)
ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less

Ambient temperature

-20 °C -4 °F to +55 °C +131 °F (no freezing)*7

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500 m/s2; 3 times each for X, Y, and Z axes

Case material

Main unit and cover: polycarbonate

Weight

Approx. 23 g

*1 This counts as 1 output when connecting multiple units to the FS-MC8N/P, NU Series.
*2 Restrictions when S-HSPD is selected
Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.
Output timer, Limit Detection, and Display Gain cannot be used.
FULL cannot be selected for the ECO function.
*3 Restrictions when HSPD is selected
Display Gain cannot be used.
*4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
*5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
*6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.
*7 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.
When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.
The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.
Exercise special care when installing the product in an airtight space.