Multi-Sensor Ionizer
SJ-F700 series
Specs Multi-Sensor Ionizer SJ-F700 series
| Model | SJ-F700 | |||
| Image | 
 | |||
| Voltage application method | Variable DC | |||
| Applied voltage | ±8200 V max. | |||
| Ion balance control method | Multi-I.C.C | |||
| Ion balance | When using SJ-FB01: ±1 V *1 *2 | |||
| Static elimination time | Approx. 0.5 s *3 *2 | |||
| Installation distance | 50 mm 1.97" or more | |||
| Maximum air volume | 4.8 m3/min 169.51 ft3/min | |||
| Ozone density | 0.005 ppm or less | |||
| Saved data | Items | Date/time, Ion level, Electrostatic charge level, Air flow, Unit status, | ||
| Sampling cycle | 0.1 s | |||
| Data history | Data saved every hour | |||
| Event log | Saved events: Errors, Warnings, Charge level threshold exceeded, Ion balance threshold | |||
| Other functions | Auto-clean, Sensor feedback | |||
| Input | IN1 | Static elimination stop input | Bidirectional voltage input | |
| IN2 | Clean input | |||
| IN3 | Event trigger input | |||
| Output | Output | Photo MOS relay output, N.O./N.C. switchable, | ||
| Number of outputs | 3 (OUT1 to OUT3) | |||
| Functions | Assignable functions: Static elimination status, Ion level alarm, Condition alarm, Fan rotation | |||
| Ethernet | Standard | 100BASE-TX | ||
| Connector | RJ-45 8-pin connector | |||
| Rating | Power voltage | 24 VDC ±10% or dedicated AC adapter (OP-88766) | ||
| Current consumption | Normal (including input/output load): 1.6 A or less | |||
| Environmental resistance | Ambient temperature | 0 to +40°C 32 to +104°F (0 to +45°C 32 to +113°F when using OP-88767 or OP-88768) | ||
| Relative humidity | 35 to 85% RH (no condensation) | |||
| Overvoltage category | I | |||
| Pollution degree | 2 | |||
| Material | Case: PC / ABS *7, Front ventilation guard: SUS, Rear suction guard: SUS, Louvers: PC / ABS *7, | |||
| Weight | Approx. 1.2 kg 2.65 lb | |||
| *1 At a distance of 300 mm 11.81" with minimum air flow, straight louvers, and relative humidity of 65% | ||||
| Model | SJ-FB01 | |||
| Image | 
 | |||
| Ion balance measurement | Measurement range | ±50 V | ||
| Measurement accuracy | ±0.5 V *1 | |||
| Minimum display unit | 0.1 V | |||
| Sampling cycle | 0.1 s | |||
| Installation distance | 50 mm 1.97" or more from SJ-F700 | |||
| Temperature measurement | Measurement range | 0 to +50°C 32 to 122°F | ||
| Measurement accuracy | ±2°C ±3.6°F *2 | |||
| Minimum display unit | 0.1°C 32.18°F | |||
| Sampling cycle | 0.5 s | |||
| Humidity measurement | Measurement range | 10 to 85% RH | ||
| Measurement accuracy | ±5% RH *2 | |||
| Minimum display unit | 1% RH | |||
| Sampling cycle | 0.5 s | |||
| Environmental resistance | Ambient temperature | 0 to +50°C 32 to +122°F | ||
| Relative humidity | 10 to 85% RH (no condensation) | |||
| Material | Case: PBT | |||
| Weight | Approx. 30 g 1.05 oz | |||
| *1 At ±15 V or less; ±10% (indicated) for other ranges | ||||