CMOS Multi-Function Analog Laser Sensor

IL series

Sensor head IL-S100

IL-S100 - Sensor head

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD / CAE

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

IL-S100*1

Reference distance

100 mm 3.94"

Measurement range

70 to 130mm0.276" to 5.118"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 laser product (FDA (CDRH) Part 1040.10,*2 IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 110 x 2,700 µm

Linearity

±0.025% of F.S. (when used at a distance of 70 to 100 mm 2.75" to 3.94"), ±0.07% of F.S. (when used at a distance of 70 to 130 mm 2.75" to 5.11")*3

Repeatability

4 µm*4

Sampling rate

0.33/1/2/5 ms (Variable to 4 levels)

Operation status indicators

Laser emission warning indicator: green LED, analog range indicator: orange LED, reference distance indicator: red/green LED

Temperature characteristics

0.03% of F.S./°C *5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 10,000 lux*6

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT Metal parts: SUS304 Packing: NBR Lens cover: Glass Cable: PVC

Weight

Approx. 75 g

*1 Amplifiers purchased before August 16th, 2011 cannot be used.
*2 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA (CDRH) Laser Notice.
*3 This value was taken when measuring a KEYENCE standard target (white diffuse object). The F.S. for each model is as shown on the right. IL-S025/030: ±5 mm ±0.20", IL-S065/065: ±10 mm±0.39", IL-100: ±20 mm ±0.79", IL-S100: ±30 mm ±1.18", IL-300: ±140 mm ±5.51", IL-600: ±400 mm ±15.74"
*4 These values were taken when measuring a KEYENCE standard target (white diffuse object) at a reference distance and with a sampling cycle of 1 ms and the number of averaging measurements set to 128. 2 ms for the IL-300/IL-600
*5 The F.S. for each model is as shown on the right. IL-S025/030: ±5mm 0.20", IL-S065/065: ±10 mm 0.39", IL-100: ±20 mm 0.79", IL-S100: ±30 mm 1.18", IL-300: ±140 mm 5.51", IL-600: ±400 mm 15.75"
*6 These are the values when the sampling cycle has been set to 2 ms or 5 ms.