High-Speed, High-Precision, Wide-Area Static Elimination Blower
SJ-F2000/5000 series
Specs High-Speed, High-Precision, Wide-Area Static Elimination Blower SJ-F2000/5000 series
Model |
SJ-F2500 |
SJ-F5500 |
|||
Image |
|
|
|||
Type |
300 mm 11.81" type |
600 mm 23.62" type |
|||
Voltage application method |
Pulse AC method |
||||
Applied voltage |
±7000V |
||||
Ion balance control method |
I.C.C. |
||||
Ion balance |
±5 V*1 |
||||
Static elimination time |
Approx. 0.6 sec*2 |
||||
Operating distance |
50 mm 1.97" min. |
||||
Maximum wind speed |
5.7 m/s 18.70 ft/s*1 |
||||
Maximum air volume |
4.0 m3/min 141.26 CFM |
10.0 m3/min 353.15 CFM |
|||
Ozone density |
0.005 ppm max. |
||||
Power source input type |
KEYENCE AC Adapter or DC Option |
AC cord input |
|||
Rating |
Power voltage |
24 VDC ±10 % |
100 to 240 VAC, 50/60 Hz |
||
Current consumption |
1.2 A |
||||
Power consumption |
90 VA |
||||
Environmental resistance |
Pollution degree |
2 |
|||
Overvoltage category |
II |
||||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||||
Relative humidity |
35 to 65 % RH |
||||
Weight |
Approx. 2 kg |
Approx. 5 kg |
|||
*1 Measured at a distance of 300 mm 11.81" from the front of the fan |
Model |
SJ-F2000 |
SJ-F5000 |
SJ-F2010 |
SJ-F5010 |
|||
Image |
|
|
|
|
|||
Type |
300 mm 11.81" type |
600 mm 23.62" type |
300 mm 11.81" type |
600 mm 23.62" type |
|||
Voltage application method |
Pulse AC method |
||||||
Applied voltage |
±7000V |
||||||
Ion balance control method |
I.C.C. |
||||||
Ion balance |
±5 V*1 |
||||||
Static elimination time |
Approx. 1 sec*2 |
||||||
Operating distance |
50 mm 1.97" min. |
||||||
Maximum wind speed |
3.5 m/s 11.48 ft/s*1 |
||||||
Maximum air volume |
2.5 m3/min 88.29 CFM |
6.2 m3/min 218.95 CFM |
2.5 m3/min 88.29 CFM |
6.2 m3/min 218.95 CFM |
|||
Ozone density |
0.005 ppm max. |
||||||
Power source input type |
KEYENCE AC Adapter or DC Option |
AC cord input |
Terminal block DC input |
||||
Control input |
Static elimination stop input |
― |
24 VDC input |
||||
Control output |
Alarm/ Ion level alert/ Condition alert |
NPN open-collector |
100 mA (40 V max.) |
||||
PNP open-collector |
100 mA (24 V ±10%) |
||||||
Rating |
Power voltage |
24 VDC ±10 % |
100 to 240 VAC, 50/60 Hz |
24 VDC ±10 % |
|||
Current consumption |
0.9 A |
1.0 A |
1.9 A |
||||
Power consumption |
65 VA |
||||||
Environmental resistance |
Pollution degree |
2 |
|||||
Overvoltage category |
II |
||||||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||||||
Relative humidity |
35 to 65 % RH |
||||||
Weight |
Approx. 2 kg |
Approx. 5 kg |
Approx. 2 kg |
Approx. 4 kg |
|||
*1 Measured at a distance of 300 mm 11.81" from the front of the fan |
Model |
SJ-U3 |
|||
Image |
|
|||
Rating |
Rating input |
100 to 240 VAC (50/60Hz) |
||
Rated output |
24VDC 2.7A |
|||
Environmental resistance |
Ambient temperature |
0 to +35°C 32 to +95°F |
||
Relative humidity |
20 to 80% (no condensation) |
|||
Weight |
Approx. 260g |