          SPECIFICATIONS

          Select Language

          Model

          GL-T11R

          Applicable model

          GL-R Series

          Relay output

          FSD1,2

          250 VAC 6 A 30 VDC 6 A (Resistance load)
          240 VAC 2 A (COSø=0.3) (Inductive load)
          24 VDC 1 A (COSø=0.3) (Inductive load)

          Life-span

          Electrical life-span

          100,000 cycles or more with 250 VAC 6 A resistance load
          (open/close frequency: 20 times/minute)
          100,000 cycles or more with 30 VDC 6 A resistance load
          (open/close frequency: 20 times/minute)
          500,000 cycles or more with 250 VAC 1 A resistance load
          (open/close frequency: 30 times/minute)
          500,000 cycles or more with 30 VDC 1 A resistance load
          (open/close frequency: 30 times/minute)
          AC15: 100,000 cycles or more with 240 VAC 2 A inductive load
          (open/close frequency: 20 times/minute, cosø = 0.3)
          DC13: 100,000 cycles or more with 24 VDC 1 A inductive load
          (open/close frequency: 20 times/minute, L/R = 48 ms)

          Response time

          ON→OFF

          GL-R +10 ms

          OFF→ON

          GL-R +32 ms

          Supplemental output
          (Non-safety-related output)

          AUX

          Transistor output (PNP/NPN input device can be connected.)*1
          50 mA max., residual voltage 2.5 V max.
          (When the cable between the GL-R and GL-T11R is 5 m)

          Error output

          Muting lamp output

          Incandescent lamp (24 VDC, 1 to 5.5 W)
          LED lamp (load current: 10 to 230 mA) can be connected.

          External input

          EDM input
          Wait input
          Reset input
          Muting input 1, 2
          Override input

          ON voltage: [Power supply voltage - 5 V] to [Power supply voltage]
          OFF voltage: Open or 0 to 3 V
          Short circuit current: Approx. 2.5 mA
          (Approx. 10 mA with EDM input only)

          Rating

          Power voltage

          24 VDC ±10%, ripple (P-P) 10% or less, Class 2

          Current consumption.

          100 mA max. (24 VDC, GL-T11R only)

          Approved standards

          EMC

          EMS

          EN61496-1, UL61496-1, IEC61496-1

          EMI

          EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

          Safety

          EN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE)
          EN ISO13849-1 : 2015 (Category4, PLe)
          UL508, EN50178

          Environmental resistance

          Enclosure rating

          IP20 (IEC60529)
          Must be installed within a control panel rated at IP54 or higher.

          Pollution degree

          2

          Overvoltage category

          III

          Operating ambient temperature

          -10 to +55 °C 14 to 131 °F (No freezing)

          Storage temperature

          -25 to +60 °C -13 to 140 °F (No freezing)

          Operating relative humidity

          15 to 85 % RH (No condensation)

          Storage relative humidity

          15 to 95 % RH

          Altitude

          2,000 m or less

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Material

          Main unit case

          Polycarbonate

          Weight

          Approx. 310 g

          *1 The output operation is the same as that when the PNP output type cable is used.

          • General Catalog Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE CORPORATION OF AMERICA 500 Park Boulevard, Suite 200, Itasca,
          IL 60143, U.S.A.
          Phone: 1-888-KEYENCE [1-888-539-3623]
          Callers from some carriers are experiencing difficulty reaching us. If you receive a busy tone, please try again or email us at the address below. E-mail: tech@keyence.com
          Career Opportunities: KEYENCE Career Site

          Safety