High-Accuracy Inline Electrostatic Sensor

SK series

Specs High-Accuracy Inline Electrostatic Sensor SK series

In-line type sensor head

Model

SK-300

SK-050

Image

Charge potential measurement

Measurement mode

High-accuracy mode, Wide-range mode

Reference distance

High-precision mode

25 mm 0.98"

Wide-range mode

100 mm 3.94"

Measuring distance

High-precision mode

1 to 50 mm 0.04" to 1.97"

5 to 50 mm 0.20" to 1.97"

Wide-range mode

60 to 120 mm 2.36" to 4.72"

Measuring range

High-precision mode

±2 kV *1

Wide-range mode

±50 kV *1 *2

Measuring accuracy

High-precision mode

±1 V *3

±10 V *7

Wide-range mode

±100 V *3

±100 V *7

Sampling cycle

Approx. 1.4 ms

Temperature measurement

Measuring range

0 to 50°C 32 to 122°F

Measuring accuracy

±1°C ±1.8°F *4

Display resolution

0.1°C 0.18°F

Sampling cycle

1 s

Humidity measurement

Measuring range

10 to 85% RH

Measuring accuracy

±5% RH *4

Display resolution

0.1% RH

Sampling cycle

1 s

Ion balance measuring mode

Ion balance measuring range

±300 V *5

±1 kV *5

Measuring accuracy

±3 V *5 *6

±10 V *5 *8

Display resolution

0.1 V *5

1 V *5

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122°F (No freezing or condensation)

Relative humidity

85% RH or less (No condensation)

10 to 85% RH (no condensation)

Pollution degree

3

-

Material

Body case: PC, Metal parts: SUS, Cable: PVC

Weight

Approx. 35 g 1.24 oz

*1 If the distance to the sensing target is shorter than the reference distance, even if the conditions are within the measurable range, measurement cannot be performed up to the upper limit of the measuring range.
*2 Measurement accuracy is satisfied in the range of ±30 kV.
*3 Within ±50 V when using high-accuracy mode; within ±1 kV when using wide-range mode. In other ranges, accuracy is ±2% (display value) in high-accuracy mode, and ±10% (display value) in wide-range mode. The value for high-accuracy mode is obtained from a mean of 1024 measurements. The value for wide-range mode is obtained from a mean of 256 measurements.
*4 At 25°C 77°F with 50% RH.
*5 OP-87934 is required.
*6 Within ±50 V. In other ranges, accuracy is ±6% (display value).
*7 Within ±100 V when using high-precision mode; within ±1 kV when using wide-range mode. In other ranges, display value has an accuracy of ±10% (display value). Values are obtained from a mean of 256 measurements.
*8 Within ±100 V. In other ranges, display value has an accuracy of ±10% (display value).

Back to top

In-line type amplifier unit

Model

SK-3000

SK-3050

SK-1000

SK-1050

Image

Type

DIN rail mounting

Main unit/expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Display

Display resolution

0.1 V

0.001 kV

Display range

-

±99.999 kV to 99 kV (4-level selection available)

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω *1

None

±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω *1

None

Analog current output

4 to 20 mA, Max. load resistance: 350 Ω *1

4 to 20 mA, Max. load resistance: 350 Ω *1

Control input

Zero-shift input

Switchable between non-voltage input and voltage input
[Non-voltage input] ON voltage: 2 V or less, OFF current: 0.02 mA or less
[Voltage input] Maximum input rating: 30 V or less, ON voltage: 7.5 V or more, OFF current: 0.05 mA or less
*2

Non-voltage input *6

Timing input

Reset input

Bank input

Control output

Judgment output

Open collector output (NPN/PNP switching, N.O./N.C. switching) *3

Alarm output

Open collector output (NPN/PNP switching, N.C.) *3

Power supply

Power supply voltage

10 to 30 VDC (including ripple (P-P) 10% or less) *4

Supplied from main unit *4

10 to 30 VDC (including ripple (P-P) 10% or less) *4

Supplied from main unit *4

Power consumption

1650 mW or less (55 mA or less at 30 V) (excluding load current of each output) *5

1170 mW or less (39 mA or less at 30 V) (excluding load current of each output) *5

1650 mW or less (55 mA or less at 30 V) (excluding load current of each output) *5

1170 mW or less (39 mA or less at 30 V) (excluding load current of each output) *5

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122°F (No freezing or condensation)

Relative humidity

85% RH or less (No condensation)

10 to 85% RH (no condensation)

Pollution degree

2

-

Material

Body case and front cover: PC, Key top: POM, Cable: PVC

Weight

Approx. 150 g 5.30 oz (including accessories)

Approx. 140 g 4.94 oz (including accessories)

Approx. 150 g 5.30 oz (including accessories)

Approx. 140 g 4.94 oz (including accessories)

*1 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use.
*2 Inputs are assigned to the four external input lines.
*3 NPN open collector output rating: maximum 50 mA/ch (20 mA/ch when expansion units are added), 30 V or less, residual voltage: 1 V or less (1.5 V or less when adding 6 or more expansion units, including main unit);
PNP open collector output rating: maximum 50 mA/ch (20 mA/ch when expansion units are added),
below power supply voltage, residual voltage: 2 V or less (2.5 V or less when adding 6 or more expansion units, including main unit)
*4 Use 20 to 30 V as the power supply voltage when using 6 or more expansion units, including the main unit.
*5 When connecting 8 units for DL connection, the maximum power consumption is 11.3 W.
*6 Inputs are assigned to the four external input lines. Non-voltage input rating: ON voltage 2 V or lower, OFF current 0.02 mA or lower. Voltage input rating: maximum input rating is 30 V, ON voltage 7.5 V or higher, OFF current 0.05 mA or below.

Back to top