Sensor, Long range, Monochrome, Manual focus model IV-2000M

IV-2000M - Sensor, Long range, Monochrome, Manual focus model

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

IV-2000M

Type

Long range

Installed distance

300 to 2,000 mm 11.81" to 78.74"

View

Installed distance 300 mm 11.81": 45 (H) × 33 (V) mm 1.77" (H) × 1.30" (V) to
installed distance 2000 mm 78.74": 300 (H) × 225 (V) mm 11.81" (H) × 8.86" (V)

Image sensor

Type

1/3 inch monochrome CMOS

Pixel

752 (H) x 480 (V) 29.61" (H) x 18.90" (V)

Focus adjustment

Manual

Exposure time

1/10 to 1/25,000

Lights

Illumination

Infrared LED

Lighting method

Pulse lighting/DC lighting is switchable

Tools

Type

Shape Detection, Color Area*1, Area*2, position adjustment

Number

Detection tools: 16 tools, position adjustment tool: 1 tool*3

Switch settings (programs)

32 programs

Image history

Numbers

300 images*4*5

Condition

NG only/All is selectable*5

Analysis information

OFF/Statistics/Histograms is switchable
Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools
Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*6

Other functions

HDR, HighGain, Color filters*1, Digital zoom*7, Brightness correction, Tilt correction, White balance*1,
Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator*8

Indicators

PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

Input

Type

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Inputs

6 inputs (IN1 to IN6)

Function

IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
Assignable functions: Program switching, Clear error, External master image registration

Output

Type

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower
For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower

Outputs

4 outputs (OUT1 to OUT4)

Function

Enable by assigning the optional functions
Assignable functions: Total judge result, RUN, BUSY, Error, Position adjustment result, Judge result of each tool, Result of the logical operation of each tool

Ethernet

Standard

100BASE-TX/10BASE-T*9

Connector

M12 4pin connector*9

Network function

FTP client, EtherNet/IP™, PROFINET

Rating

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

0.6 A or less

Environmental resistance

Enclosure rating

IP67*10

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*11

Shock resistance

500 m/s2, 3 times in each of 6 directions*11

Material

Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM

Weight

Approx. 270 g

*1 Color type only
*2 Possible with both the Color type and monochrome type
*3 Tools can be installed by programs.
*4 When using the FTP client function: 210 pictures
*5 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1).
*6 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1).
*7 Possible with both the color type and monochrome type
*8 Simulator can be used with the IV software (IV-H1).
*9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1).
*10 Except when polarized filter attachment (OP-87436/OP-87437) is mounted
*11 Except when IV-G dome attachment (IV-D10) is mounted

Data Sheet (PDF) Other Models