Battery Manufacturing Measurement Guide: What to Measure at Each Process

From electrode coating to pack assembly, we have organized “what to measure, why to measure, and which series to use” for each battery manufacturing process. This process guide allows you to find the necessary measurements for your specific process.

View Catalog

Inquiries about measurements for battery manufacturing processes

What Happens When In-Process Measurement Is Missed in Battery Manufacturing

Batteries have a long manufacturing process, and variations in previous processes appear as defects in subsequent processes.

Variations in Previous Processes Cannot Be Recovered in Subsequent Processes

Thickness variations caused during electrode coating or pressing remain in the cells as differences in capacity and internal resistance, and cannot be recovered through adjustments in subsequent processes. The later the variation is noticed—such as during post-completion inspection—the larger the number of discarded cells and the scope of rework. Measuring thickness and width in-process to enable immediate adjustment back to target conditions is a prerequisite for protecting the yield rate and production plans.

The Measurement Target Changes for Each Process, Leading to Individualized Selection of Measurement Methods

In battery manufacturing, both the measurement targets and the suitable methods change for each process, from coating thickness to slitting, winding, welding, and assembly. If each operator makes decisions based on the measuring instruments they have on hand, data collection methods will not be consistent across processes, making it impossible to trace the causes of defects across different stages. Organizing “what to measure” in process order is the fastest way to make the right selection.

Sample Inspection Cannot Keep up With Mass Production Speeds

On large-scale lines, it is necessary to measure fast-moving electrodes and cells without stopping them. With sample or offline measurements, a large volume of intermediate products will pass through before an abnormality is detected, and the internal state cannot be re-measured after sealing. The longer the time from defect occurrence to detection, the more man-hours are required to isolate the cause. A system that tracks transfer speeds and performs 100% non-contact measurement is essential for quality control in the mass production stage.

What to Measure by Process, From Electrode Coating to Pack Assembly

We have listed “what to measure,” “why to measure,” and “which series to use” in process order. Please check the card for your process.

  1. 1 Electrode coating – Process ①. Measures the thickness of the active material layer coated on the current collector foil at multiple points in the width direction. Since variations in coating thickness remain until the end as differences in capacity and internal resistance, non-contact thickness measurement is performed using the CL-3000 Series or similar.
    Battery Material Thickness Measurement Guide
  2. 2 Calendering (roll pressing) – Process ②. Measures the electrode thickness after roll pressing to confirm if it is within the target thickness. The CL-S015 thickness measurement head, with its athermal optical design, is less susceptible to heat generated by the rolls or electrodes, enabling stable measurement.
    Electrode Plate Thickness Measurement Guide
  3. 3 Slitting – Process ③. Measures the width and edge shape of the electrode after slitting. Since edge irregularities lead to misalignment during winding and stacking, the LJ-X8000 Series, which can check the cross-sectional shape, is effective.
  4. 4 Winding/Stacking – Process ④. Measures the winding misalignment of each electrode and the width after stacking. Since misaligned parts cannot be corrected once they move to the next process, the cross-sectional shape after winding is measured with the LJ-X8000 Series, and the position and width of each layer on the stacked end face are measured with the CL-3000 Series.
  5. 5 Electrolyte Injection/Sealing – Process ⑤. Measures the case height before injection to control the injector height. The CL-3000 Series, which can stably measure the height of deep recessed areas coaxially, is responsible for this.
  6. 6 Tab Welding/Terminal Welding – Process ⑥. Measures the amplitude of the ultrasonic welder and the bead shape after welding. Since the condition of the welded part affects cell quality, the amplitude is checked with the LK-G5000 Series and the bead shape with the LJ-X8000 Series.
  7. 7 Cell Inspection (Appearance/Dimensions) – Process ⑦. Simultaneously inspects the dimensions, flatness, and welding status of each cell surface. The LJ-X8000 Series, which uses multiple sensor heads capable of measuring wide widths, can inspect the necessary surfaces all at once.
  8. 8 Module/Pack Assembly – Process ⑧. Measures the height, steps, and flatness of modules and packs after cells are assembled. Since variations after assembly lead to rework involving disassembly, non-contact 100% inspection is integrated into the process.

Comparison of Methods Used for In-Process Measurement in Battery Manufacturing

Depending on the method, the ease of 100% measurement, the impact on the target, and the range of measurable items will change.

Comparison items Non-contact laser measurement
(High Precision Measurement Series)
Contact method (micrometer, etc.) Sample inspection/offline measurement Radiation transmission method (beta-ray/X-ray)
100% inline measurement
Non-contact laser measurement (High Precision Measurement Series)
◎ 100% in-process measurement
Contact method (micrometer, etc.)
× Stopping and setup required
Sample inspection/offline measurement
× Sample inspection only
Radiation transmission method (beta-ray/X-ray)
○ In-process measurement
Effect on target (scratches/deformation)
Non-contact laser measurement (High Precision Measurement Series)
○ Non-contact, minimal effect
Contact method (micrometer, etc.)
× Risk of contact/deformation
Sample inspection/offline measurement
△ Removal and transport required
Radiation transmission method (beta-ray/X-ray)
○ Non-contact
Ability to keep up with high-speed conveyance
Non-contact laser measurement (High Precision Measurement Series)
◎ Tracks with high-speed sampling
Contact method (micrometer, etc.)
× Cannot measure while moving
Sample inspection/offline measurement
× Incompatible with line speed
Radiation transmission method (beta-ray/X-ray)
△ Depends on scanning speed
Multi-point measurement in the width direction
Non-contact laser measurement (High Precision Measurement Series)
◎ Multi-point measurement by synchronizing multiple heads
Contact method (micrometer, etc.)
× Cannot increase the number of points
Sample inspection/offline measurement
× Limited points only
Radiation transmission method (beta-ray/X-ray)
△ Scanning mechanism is required
Inspection of 3D shapes and welded parts
Non-contact laser measurement (High Precision Measurement Series)
◎ Inspection using cross-sectional shape/3D shape
Contact method (micrometer, etc.)
× Cannot measure shape
Sample inspection/offline measurement
△ Depends on visual inspection/microscope
Radiation transmission method (beta-ray/X-ray)
× Not applicable
Management load for installation and operation
Non-contact laser measurement (High Precision Measurement Series)
○ No management of radiation source required
Contact method (micrometer, etc.)
○ Light management load
Sample inspection/offline measurement
△ Requires labor and time
Radiation transmission method (beta-ray/X-ray)
× Requires management of radiation source and compliance with laws and regulations

Reasons for Choosing Non-Contact Laser Measurement Across Processes

Although the target and method of measurement change for each process in battery manufacturing, non-contact laser measurement allows everything from coating thickness to weld shape and cell/pack dimensions to be integrated into the process using the same concept. There is no need to manage radiation sources, and synchronizing multiple heads enables multi-point measurement in the width direction. This allows data collection methods to be standardized across processes.

Precision Measurement Series for Battery Manufacturing Processes

Different series with different measurement methods are used depending on the target to be measured in the process.

Cross-Process Support From Electrodes to Pack Assembly — Battery Measurement Series

Non-Contact Measurement Solutions for Battery Manufacturing Processes

The CL-3000 Series confocal displacement sensor handles the thickness, height, and width of electrodes and cells (simultaneous measurement by connecting up to 6 sensor heads). The LK-G5000 Series, with a maximum sampling rate of 392 kHz and connection of up to 12 heads, is used for measuring the amplitude of ultrasonic welding machines. The LJ-X8000 Series, which can measure widths up to 720 mm with a single sensor head, is responsible for inspections based on cross-sectional or 3D shapes, such as winding misalignment, weld beads, and cell dimensions. For detailed measurement methods for each process, please refer to the application examples below and the individual guides for some processes.

View Catalog

Click here for CL-3000 Series product information

Click here for LK-G5000 Series product information

Click here for LJ-X8000 Series product information

Get Materials on Non-Contact Measurement for Battery Manufacturing Processes

You can download a free collection of applications summarizing measurement examples for each process.

View Catalog

Inquiries about measurements for battery manufacturing processes

Examples of Measurement Applications in Battery Manufacturing Processes

It is used for measurement in each process, such as after electrode pressing, winding, and stacking.

Electrode Thickness Measurement After Pressing

Measures electrode thickness immediately after pressing with high accuracy and without contact. The CL-S015 thickness measurement head, with its athermal optical design, is less susceptible to heat generated by rolls or electrodes, enabling stable measurement over long periods.

Electrode Stacking Misalignment Inspection

After the stacking process, inspections are performed to check for stacking misalignment. The CL-PT010 shape measurement head, with a minimum spot diameter of φ3.5 µm, can stably measure the edge position of each individual electrode.

Width Measurement After Battery Stacking

Measures the width after stacking without contact. Even for targets that are difficult to measure with large calipers, the CL-3000 Series enables easy, high-accuracy non-contact measurement.

Frequently Asked Questions About Measurement in Battery Manufacturing Processes

Q What should be measured at each stage of battery manufacturing?

A

Typical measurements include electrode coating thickness, electrode thickness after pressing, width and edge shape after slitting, winding misalignment after winding, case height before injection, weld shape, and cell dimensions/flatness. A list in process order can be found in the “Process” section of this page.

Q Can electrode coating thickness be measured without contact?

A

Yes, it can. The CL-S015 thickness measurement head, with its athermal optical design, is less susceptible to heat generated by rolls or electrodes, enabling stable measurement over long periods. In addition, the CL-3000 Series can connect up to 6 sensor heads for simultaneous measurement, allowing multiple points in the width direction to be captured.

Q Can winding misalignment after winding/stacking be inspected?

A

Yes, it can. For winding misalignment after winding, the LJ-X8000 Series inspects each individual electrode using its cross-sectional shape. Stacking misalignment for each layer after stacking and the width after stacking are measured without contact using the CL-3000 Series.

Q How do you check the quality of tab welding?

A

The amplitude of the ultrasonic welding machine is checked with the LK-G5000 Series, and the bead shape after welding is checked with the LJ-X8000 Series. The LJ-X8000 Series is equipped with four types of dedicated measurement tools: throat thickness, leg length, undercut, and overlap.

Q Can the dimensions and flatness of prismatic cells and modules also be measured?

A

Yes, they can. The LJ-X8000 Series can simultaneously measure the dimensions and flatness of each side of the battery, as well as inspect the welding condition. By using multiple sensor heads that can measure wide widths with high accuracy, the required surfaces of the product can be inspected all at once.

Related Products